{"title":"生物可降解聚合物包被西罗莫司洗脱支架在st段抬高型心肌梗死患者中的早期血管反应- OCIMI研究","authors":"Atul Abhyankar, Bhargav Patel, Ankit Jain, Vikas Patel, Yamunesh Patel, Kan Saito, Akihiro Yoshida, Yasuhiro Honda, Krishnankutty Sudhir","doi":"10.1002/ccd.70046","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Few studies have addressed the early healing pattern of ultrathin strut drug-eluting stents implanted specifically for the treatment of acute myocardial infarction.</p><p><strong>Aims: </strong>This study employed optical coherence tomography (OCT) to assess neointimal coverage and vascular healing following implantation of ultrathin biodegradable polymer-coated sirolimus-eluting stents (SES) in patients with ST-segment elevation myocardial infarction (STEMI).</p><p><strong>Methods: </strong>The OCIMI study was a prospective, single-center investigation of 23 STEMI patients treated with Supraflex Cruz SES (Sahajanand Medical Technologies Ltd., Surat, India) during primary PCI between September 2019 and June 2020. All patients underwent OCT imaging at 3-month follow-up, and images were analyzed at an independent core laboratory by analysts blinded to clinical and procedural data.</p><p><strong>Results: </strong>At the 3-month follow-up, no clinical events were reported. The analyzed stent length was 28.4 ± 12.0 mm, with a stent diameter of 2.70 ± 0.46 mm and a reference lumen diameter of 2.46 ± 0.44 mm. OCT demonstrated nearly complete stent strut coverage (99.94%), with uncovered struts observed in 0.06 ± 0.16% of total struts per stent. Incomplete stent apposition was present in 0.14 ± 0.37% of struts. The mean neointimal hyperplasia (NIH) area and thickness were 0.81 ± 0.40 mm<sup>2</sup> and 110 ± 40 µm, respectively, with a mean NIH unevenness score of 1.74 ± 0.19.</p><p><strong>Conclusion: </strong>Primary PCI performed with Supraflex Cruz SES demonstrated excellent early vascular healing at the 3-month OCT follow-up. The extremely low incidence of uncovered struts may have implications for abbreviated dual antiplatelet therapy in high-bleeding risk STEMI patients.</p>","PeriodicalId":520583,"journal":{"name":"Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Early Vascular Response of a Biodegradable Polymer-Coated Sirolimus-Eluting Stent in Patients With ST-Segment Elevation Myocardial Infarction-The OCIMI Study.\",\"authors\":\"Atul Abhyankar, Bhargav Patel, Ankit Jain, Vikas Patel, Yamunesh Patel, Kan Saito, Akihiro Yoshida, Yasuhiro Honda, Krishnankutty Sudhir\",\"doi\":\"10.1002/ccd.70046\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Few studies have addressed the early healing pattern of ultrathin strut drug-eluting stents implanted specifically for the treatment of acute myocardial infarction.</p><p><strong>Aims: </strong>This study employed optical coherence tomography (OCT) to assess neointimal coverage and vascular healing following implantation of ultrathin biodegradable polymer-coated sirolimus-eluting stents (SES) in patients with ST-segment elevation myocardial infarction (STEMI).</p><p><strong>Methods: </strong>The OCIMI study was a prospective, single-center investigation of 23 STEMI patients treated with Supraflex Cruz SES (Sahajanand Medical Technologies Ltd., Surat, India) during primary PCI between September 2019 and June 2020. All patients underwent OCT imaging at 3-month follow-up, and images were analyzed at an independent core laboratory by analysts blinded to clinical and procedural data.</p><p><strong>Results: </strong>At the 3-month follow-up, no clinical events were reported. The analyzed stent length was 28.4 ± 12.0 mm, with a stent diameter of 2.70 ± 0.46 mm and a reference lumen diameter of 2.46 ± 0.44 mm. OCT demonstrated nearly complete stent strut coverage (99.94%), with uncovered struts observed in 0.06 ± 0.16% of total struts per stent. Incomplete stent apposition was present in 0.14 ± 0.37% of struts. The mean neointimal hyperplasia (NIH) area and thickness were 0.81 ± 0.40 mm<sup>2</sup> and 110 ± 40 µm, respectively, with a mean NIH unevenness score of 1.74 ± 0.19.</p><p><strong>Conclusion: </strong>Primary PCI performed with Supraflex Cruz SES demonstrated excellent early vascular healing at the 3-month OCT follow-up. The extremely low incidence of uncovered struts may have implications for abbreviated dual antiplatelet therapy in high-bleeding risk STEMI patients.</p>\",\"PeriodicalId\":520583,\"journal\":{\"name\":\"Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-07-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/ccd.70046\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/ccd.70046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
背景:很少有研究报道用于治疗急性心肌梗死的超薄支架的早期愈合模式。目的:本研究采用光学相干断层扫描(OCT)评估st段抬高型心肌梗死(STEMI)患者植入超薄可生物降解聚合物涂层西罗莫司洗脱支架(SES)后的内膜覆盖和血管愈合情况。方法:OCIMI研究是一项前瞻性单中心调查,对2019年9月至2020年6月期间接受Supraflex Cruz SES (Sahajanand Medical Technologies Ltd, Surat, India)治疗的23例STEMI患者进行初步PCI治疗。所有患者在随访3个月时接受了OCT成像,图像在独立的核心实验室由不了解临床和手术数据的分析人员进行分析。结果:随访3个月,无临床事件报告。分析的支架长度为28.4±12.0 mm,支架直径为2.70±0.46 mm,参考管腔直径为2.46±0.44 mm。OCT显示支架支撑物几乎完全覆盖(99.94%),未覆盖支撑物占每个支架支撑物总数的0.06±0.16%。0.14±0.37%的支杆存在支架不完全贴合。平均新生内膜增生(NIH)面积为0.81±0.40 mm2,厚度为110±40µm, NIH不均匀度评分为1.74±0.19。结论:在3个月的OCT随访中,使用Supraflex Cruz SES进行的首次PCI显示出良好的早期血管愈合。未覆盖支架的极低发生率可能意味着在高风险STEMI患者中缩短双重抗血小板治疗。
Early Vascular Response of a Biodegradable Polymer-Coated Sirolimus-Eluting Stent in Patients With ST-Segment Elevation Myocardial Infarction-The OCIMI Study.
Background: Few studies have addressed the early healing pattern of ultrathin strut drug-eluting stents implanted specifically for the treatment of acute myocardial infarction.
Aims: This study employed optical coherence tomography (OCT) to assess neointimal coverage and vascular healing following implantation of ultrathin biodegradable polymer-coated sirolimus-eluting stents (SES) in patients with ST-segment elevation myocardial infarction (STEMI).
Methods: The OCIMI study was a prospective, single-center investigation of 23 STEMI patients treated with Supraflex Cruz SES (Sahajanand Medical Technologies Ltd., Surat, India) during primary PCI between September 2019 and June 2020. All patients underwent OCT imaging at 3-month follow-up, and images were analyzed at an independent core laboratory by analysts blinded to clinical and procedural data.
Results: At the 3-month follow-up, no clinical events were reported. The analyzed stent length was 28.4 ± 12.0 mm, with a stent diameter of 2.70 ± 0.46 mm and a reference lumen diameter of 2.46 ± 0.44 mm. OCT demonstrated nearly complete stent strut coverage (99.94%), with uncovered struts observed in 0.06 ± 0.16% of total struts per stent. Incomplete stent apposition was present in 0.14 ± 0.37% of struts. The mean neointimal hyperplasia (NIH) area and thickness were 0.81 ± 0.40 mm2 and 110 ± 40 µm, respectively, with a mean NIH unevenness score of 1.74 ± 0.19.
Conclusion: Primary PCI performed with Supraflex Cruz SES demonstrated excellent early vascular healing at the 3-month OCT follow-up. The extremely low incidence of uncovered struts may have implications for abbreviated dual antiplatelet therapy in high-bleeding risk STEMI patients.