力和力矩随唇倾量和材料类型的变化规律:六轴机械传感器的体外实验。

IF 2.3 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Korean Journal of Orthodontics Pub Date : 2025-07-25 Epub Date: 2025-04-29 DOI:10.4041/kjod25.003
Keun-Chul Cho, Il-Hyung Yang, Michael Lee, Ki Beom Kim, Seung-Hak Baek
{"title":"力和力矩随唇倾量和材料类型的变化规律:六轴机械传感器的体外实验。","authors":"Keun-Chul Cho, Il-Hyung Yang, Michael Lee, Ki Beom Kim, Seung-Hak Baek","doi":"10.4041/kjod25.003","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate the pattern of change in force and moment according to the amounts of labial tipping and the material types of clear aligners (CA).</p><p><strong>Methods: </strong>A 3D-printed maxillary typodont system, including crown, root, and periodontal ligament space, was constructed. Six groups were established based on the amount of labial tipping of #12 (0.3 mm and 0.6 mm), and the material types (Zendura [thermoplastic, one-layer, 0.75 mm], Trioclear [thermoplastic, three-layer, 0.5 mm], and Graphy TA-28 [direct printing, 0.5 mm]) (n = 6/group). A six-axis mechanical sensor apparatus was connected to the roots. Force and moment were measured after seating the CA in a 37°C water bath.</p><p><strong>Results: </strong>When comparing 0.3 mm and 0.6 mm tipping, #12 showed an increase in labial inclination moment (Lab-inclination moment) in Zendura (<i>P</i> < 0.05); a decrease in labial force and an increase in Lab-inclination-moment in Trioclear (<i>P</i> < 0.05, P < 0.01); while a lingual force and Lab-inclination moment without significant change in Graphy (all <i>P</i> > 0.05). For 0.3 mm tipping, the amounts of labio-lingual forces and Lab-inclination moment did not differ among the three materials (all <i>P</i> > 0.05). However, at 0.6 mm tipping, Zendura exerted a greater labial force than Trioclear, while Graphy produced a lingual force (<i>P</i> < 0.01). Zendura and Trioclear generated a stronger Lab-inclination moment compared to Graphy (<i>P</i> < 0.01). Despite displaying unexpected force and moment directions, Graphy consistently exhibited the lowest absolute values among the groups.</p><p><strong>Conclusions: </strong>Clinicians should select the appropriate aligner material based on the specific biomechanical requirements to prevent unexpected forces and moments.</p>","PeriodicalId":51260,"journal":{"name":"Korean Journal of Orthodontics","volume":"55 4","pages":"290-305"},"PeriodicalIF":2.3000,"publicationDate":"2025-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12301420/pdf/","citationCount":"0","resultStr":"{\"title\":\"Pattern of change in force and moment according to amounts of labial tipping and material types of clear aligner: <i>In vitro</i> experiment with a six-axis mechanical sensor apparatus.\",\"authors\":\"Keun-Chul Cho, Il-Hyung Yang, Michael Lee, Ki Beom Kim, Seung-Hak Baek\",\"doi\":\"10.4041/kjod25.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To investigate the pattern of change in force and moment according to the amounts of labial tipping and the material types of clear aligners (CA).</p><p><strong>Methods: </strong>A 3D-printed maxillary typodont system, including crown, root, and periodontal ligament space, was constructed. Six groups were established based on the amount of labial tipping of #12 (0.3 mm and 0.6 mm), and the material types (Zendura [thermoplastic, one-layer, 0.75 mm], Trioclear [thermoplastic, three-layer, 0.5 mm], and Graphy TA-28 [direct printing, 0.5 mm]) (n = 6/group). A six-axis mechanical sensor apparatus was connected to the roots. Force and moment were measured after seating the CA in a 37°C water bath.</p><p><strong>Results: </strong>When comparing 0.3 mm and 0.6 mm tipping, #12 showed an increase in labial inclination moment (Lab-inclination moment) in Zendura (<i>P</i> < 0.05); a decrease in labial force and an increase in Lab-inclination-moment in Trioclear (<i>P</i> < 0.05, P < 0.01); while a lingual force and Lab-inclination moment without significant change in Graphy (all <i>P</i> > 0.05). For 0.3 mm tipping, the amounts of labio-lingual forces and Lab-inclination moment did not differ among the three materials (all <i>P</i> > 0.05). However, at 0.6 mm tipping, Zendura exerted a greater labial force than Trioclear, while Graphy produced a lingual force (<i>P</i> < 0.01). Zendura and Trioclear generated a stronger Lab-inclination moment compared to Graphy (<i>P</i> < 0.01). Despite displaying unexpected force and moment directions, Graphy consistently exhibited the lowest absolute values among the groups.</p><p><strong>Conclusions: </strong>Clinicians should select the appropriate aligner material based on the specific biomechanical requirements to prevent unexpected forces and moments.</p>\",\"PeriodicalId\":51260,\"journal\":{\"name\":\"Korean Journal of Orthodontics\",\"volume\":\"55 4\",\"pages\":\"290-305\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-07-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12301420/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Korean Journal of Orthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4041/kjod25.003\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/4/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Orthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4041/kjod25.003","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/4/29 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:探讨唇尖矫正器(CA)材料类型和唇尖量对力和力矩的影响规律。方法:3d打印上颌牙型系统,包括牙冠、牙根和牙周韧带间隙。根据12号唇倾量(0.3 mm和0.6 mm)和材料类型(Zendura[热塑性,单层,0.75 mm]、Trioclear[热塑性,三层,0.5 mm]和Graphy TA-28[直接打印,0.5 mm])组成6组(n = 6/组)。一个六轴机械传感器连接到根部。将CA置于37°C水浴中后测量力和力矩。结果:与0.3 mm和0.6 mm的倾翻相比,#12的上唇倾倾力矩(lab -倾角力矩)增加(P < 0.05);三清组唇部力减小,lab -斜力矩增大(P < 0.05, P < 0.01);舌力和lab -倾力矩在影像学上无明显变化(P < 0.05)。对于0.3 mm的倾斜,三种材料的唇舌力和lab -倾力矩的大小没有差异(均P < 0.05)。然而,在翻尖0.6 mm时,Zendura的唇力大于triclear,而Graphy的唇力大于triclear (P < 0.01)。Zendura和triclear产生的lab -倾角力矩比Graphy更大(P < 0.01)。尽管显示出意想不到的力和力矩方向,但在组中,Graphy始终显示出最低的绝对值。结论:临床医生应根据特定的生物力学要求选择合适的矫正器材料,以防止意外的力和力矩。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Pattern of change in force and moment according to amounts of labial tipping and material types of clear aligner: In vitro experiment with a six-axis mechanical sensor apparatus.

Objective: To investigate the pattern of change in force and moment according to the amounts of labial tipping and the material types of clear aligners (CA).

Methods: A 3D-printed maxillary typodont system, including crown, root, and periodontal ligament space, was constructed. Six groups were established based on the amount of labial tipping of #12 (0.3 mm and 0.6 mm), and the material types (Zendura [thermoplastic, one-layer, 0.75 mm], Trioclear [thermoplastic, three-layer, 0.5 mm], and Graphy TA-28 [direct printing, 0.5 mm]) (n = 6/group). A six-axis mechanical sensor apparatus was connected to the roots. Force and moment were measured after seating the CA in a 37°C water bath.

Results: When comparing 0.3 mm and 0.6 mm tipping, #12 showed an increase in labial inclination moment (Lab-inclination moment) in Zendura (P < 0.05); a decrease in labial force and an increase in Lab-inclination-moment in Trioclear (P < 0.05, P < 0.01); while a lingual force and Lab-inclination moment without significant change in Graphy (all P > 0.05). For 0.3 mm tipping, the amounts of labio-lingual forces and Lab-inclination moment did not differ among the three materials (all P > 0.05). However, at 0.6 mm tipping, Zendura exerted a greater labial force than Trioclear, while Graphy produced a lingual force (P < 0.01). Zendura and Trioclear generated a stronger Lab-inclination moment compared to Graphy (P < 0.01). Despite displaying unexpected force and moment directions, Graphy consistently exhibited the lowest absolute values among the groups.

Conclusions: Clinicians should select the appropriate aligner material based on the specific biomechanical requirements to prevent unexpected forces and moments.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Korean Journal of Orthodontics
Korean Journal of Orthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.50
自引率
10.50%
发文量
48
审稿时长
>12 weeks
期刊介绍: The Korean Journal of Orthodontics (KJO) is an international, open access, peer reviewed journal published in January, March, May, July, September, and November each year. It was first launched in 1970 and, as the official scientific publication of Korean Association of Orthodontists, KJO aims to publish high quality clinical and scientific original research papers in all areas related to orthodontics and dentofacial orthopedics. Specifically, its interest focuses on evidence-based investigations of contemporary diagnostic procedures and treatment techniques, expanding to significant clinical reports of diverse treatment approaches. The scope of KJO covers all areas of orthodontics and dentofacial orthopedics including successful diagnostic procedures and treatment planning, growth and development of the face and its clinical implications, appliance designs, biomechanics, TMJ disorders and adult treatment. Specifically, its latest interest focuses on skeletal anchorage devices, orthodontic appliance and biomaterials, 3 dimensional imaging techniques utilized for dentofacial diagnosis and treatment planning, and orthognathic surgery to correct skeletal disharmony in association of orthodontic treatment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信