全髋关节置换术后过度置入骨水泥髋臼杯效果的探讨。

IF 2.3 3区 医学 Q2 ORTHOPEDICS
Teresa Alonso-Rasgado, Jose F Del-Valle-Mojica, Marcial Arrambi-Diaz, Israel Miguel-Andres, Roberto Leonardo-Diaz, Colin G Bailey, Tim N Board
{"title":"全髋关节置换术后过度置入骨水泥髋臼杯效果的探讨。","authors":"Teresa Alonso-Rasgado, Jose F Del-Valle-Mojica, Marcial Arrambi-Diaz, Israel Miguel-Andres, Roberto Leonardo-Diaz, Colin G Bailey, Tim N Board","doi":"10.1002/jor.70031","DOIUrl":null,"url":null,"abstract":"<p><p>A nonuniform cement mantle significantly affects the long-term success of cemented total hip arthroplasty (THA). Over-insertion of the acetabular cup leads to an uneven layer of cement mantle, which can cause stress concentration and potential failure, such as implant loosening. This study investigates the effect of over-insertion of the acetabular cup on the stress distribution at the cement-cup and cement-bone interface after THA and compares with the non-over-inserted case. Finite element models of synthetic bone hemipelves implanted with over-inserted cemented cups with internal diameters of 28 and 36 mm were created from CT scan data. The models were validated with surface strains obtained from a composite hemipelvis implanted with a cemented all-polyethylene acetabular cup and used to simulate a one-leg standing activity of an average weight subject of 700 N. Over-insertion of the acetabular cup led to a thinner, nonuniform cement mantle, resulting in higher stresses in the superior and anterior periacetabular regions of the cortical bone and at the bone-cement and cement-cup interface, compared to the corresponding non-over-inserted case. At the bone-cement interface, our model predicted stress increases of up to 50% in the antero-superior and 35% in the postero-superior quadrant of the joint, an area where debonding frequently initiates. In addition, a larger head diameter was associated with lower rises in bone and cement stresses resulting from uneven cement mantles. Although stresses in the cement were below yield, raised stresses in this region are associated with crack formation and growth, which could lead to implant loosening.</p>","PeriodicalId":16650,"journal":{"name":"Journal of Orthopaedic Research®","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation Into the Effect of Over-Inserted Cemented Acetabular Cups After Total Hip Arthroplasty (THA).\",\"authors\":\"Teresa Alonso-Rasgado, Jose F Del-Valle-Mojica, Marcial Arrambi-Diaz, Israel Miguel-Andres, Roberto Leonardo-Diaz, Colin G Bailey, Tim N Board\",\"doi\":\"10.1002/jor.70031\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A nonuniform cement mantle significantly affects the long-term success of cemented total hip arthroplasty (THA). Over-insertion of the acetabular cup leads to an uneven layer of cement mantle, which can cause stress concentration and potential failure, such as implant loosening. This study investigates the effect of over-insertion of the acetabular cup on the stress distribution at the cement-cup and cement-bone interface after THA and compares with the non-over-inserted case. Finite element models of synthetic bone hemipelves implanted with over-inserted cemented cups with internal diameters of 28 and 36 mm were created from CT scan data. The models were validated with surface strains obtained from a composite hemipelvis implanted with a cemented all-polyethylene acetabular cup and used to simulate a one-leg standing activity of an average weight subject of 700 N. Over-insertion of the acetabular cup led to a thinner, nonuniform cement mantle, resulting in higher stresses in the superior and anterior periacetabular regions of the cortical bone and at the bone-cement and cement-cup interface, compared to the corresponding non-over-inserted case. At the bone-cement interface, our model predicted stress increases of up to 50% in the antero-superior and 35% in the postero-superior quadrant of the joint, an area where debonding frequently initiates. In addition, a larger head diameter was associated with lower rises in bone and cement stresses resulting from uneven cement mantles. Although stresses in the cement were below yield, raised stresses in this region are associated with crack formation and growth, which could lead to implant loosening.</p>\",\"PeriodicalId\":16650,\"journal\":{\"name\":\"Journal of Orthopaedic Research®\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-07-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthopaedic Research®\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/jor.70031\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Research®","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jor.70031","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

不均匀的骨水泥套显著影响骨水泥全髋关节置换术(THA)的长期成功。髋臼杯过度插入会导致水泥套层不均匀,这可能导致应力集中和潜在的失败,如植入物松动。本研究探讨髋臼杯过插入对THA后骨水泥杯和骨水泥界面应力分布的影响,并与未过插入情况进行比较。利用CT扫描数据建立了内径分别为28和36 mm的人工骨半体的有限元模型。该模型通过植入全聚乙烯髋臼杯的复合半骨盆的表面应变进行验证,并用于模拟平均体重为700牛顿的单腿站立活动。髋臼杯过度插入导致骨水泥套更薄、不均匀,与相应的未过度插入病例相比,骨皮质骨的上部和前部髋臼周围区域以及骨水泥和骨水泥杯界面处的应力更高。在骨水泥界面,我们的模型预测关节前上象限的应力增加高达50%,后上象限的应力增加35%,这是一个经常发生脱粘的区域。此外,较大的头部直径与较低的骨水泥应力升高有关,这是由不均匀的水泥膜引起的。尽管水泥中的应力低于屈服,但该区域的应力升高与裂缝的形成和增长有关,这可能导致植入物松动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation Into the Effect of Over-Inserted Cemented Acetabular Cups After Total Hip Arthroplasty (THA).

A nonuniform cement mantle significantly affects the long-term success of cemented total hip arthroplasty (THA). Over-insertion of the acetabular cup leads to an uneven layer of cement mantle, which can cause stress concentration and potential failure, such as implant loosening. This study investigates the effect of over-insertion of the acetabular cup on the stress distribution at the cement-cup and cement-bone interface after THA and compares with the non-over-inserted case. Finite element models of synthetic bone hemipelves implanted with over-inserted cemented cups with internal diameters of 28 and 36 mm were created from CT scan data. The models were validated with surface strains obtained from a composite hemipelvis implanted with a cemented all-polyethylene acetabular cup and used to simulate a one-leg standing activity of an average weight subject of 700 N. Over-insertion of the acetabular cup led to a thinner, nonuniform cement mantle, resulting in higher stresses in the superior and anterior periacetabular regions of the cortical bone and at the bone-cement and cement-cup interface, compared to the corresponding non-over-inserted case. At the bone-cement interface, our model predicted stress increases of up to 50% in the antero-superior and 35% in the postero-superior quadrant of the joint, an area where debonding frequently initiates. In addition, a larger head diameter was associated with lower rises in bone and cement stresses resulting from uneven cement mantles. Although stresses in the cement were below yield, raised stresses in this region are associated with crack formation and growth, which could lead to implant loosening.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Orthopaedic Research®
Journal of Orthopaedic Research® 医学-整形外科
CiteScore
6.10
自引率
3.60%
发文量
261
审稿时长
3-6 weeks
期刊介绍: The Journal of Orthopaedic Research is the forum for the rapid publication of high quality reports of new information on the full spectrum of orthopaedic research, including life sciences, engineering, translational, and clinical studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信