{"title":"基于矩阵探针的后向散射系数体积估计","authors":"Valentin Mazellier;François Varray;Pauline Muleki-Seya","doi":"10.1109/OJUFFC.2025.3588811","DOIUrl":null,"url":null,"abstract":"Evaluation of the backscatter coefficient (BSC) from soft tissues has many applications for medical diagnosis. However, electronic noise and spatial variations often affect BSC estimation, requiring spatial averaging inside a region of interest (ROI) that reduces spatial resolution compared to the B-mode images. This study explores 3D BSC estimation using a matrix probes to address this trade-off by allowing narrower ROIs without losing robustness. A comparison study between a 1024-element matrix probe (V8) and two linear probes (L12-5, L22-8) was made on homogeneous agar-based phantoms with Orgasol particles (5, 10, and <inline-formula> <tex-math>$20~\\mu $ </tex-math></inline-formula>m). BSC was computed using the reference phantom method, and robustness was assessed via the BSC standard deviation across ROIs. Results showed that, despite the lower B-mode resolution and longer correlation length between A-lines, volumetric estimation with a matrix probe offered comparable accuracy while enhancing robustness and resolution in the BSC map compared to the standard 2D estimation. These results could be beneficial for the analysis of complex heterogeneous media.","PeriodicalId":73301,"journal":{"name":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","volume":"5 ","pages":"119-122"},"PeriodicalIF":2.9000,"publicationDate":"2025-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11079648","citationCount":"0","resultStr":"{\"title\":\"Volumetric Estimation of the Backscatter Coefficient With a Matrix Probe\",\"authors\":\"Valentin Mazellier;François Varray;Pauline Muleki-Seya\",\"doi\":\"10.1109/OJUFFC.2025.3588811\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Evaluation of the backscatter coefficient (BSC) from soft tissues has many applications for medical diagnosis. However, electronic noise and spatial variations often affect BSC estimation, requiring spatial averaging inside a region of interest (ROI) that reduces spatial resolution compared to the B-mode images. This study explores 3D BSC estimation using a matrix probes to address this trade-off by allowing narrower ROIs without losing robustness. A comparison study between a 1024-element matrix probe (V8) and two linear probes (L12-5, L22-8) was made on homogeneous agar-based phantoms with Orgasol particles (5, 10, and <inline-formula> <tex-math>$20~\\\\mu $ </tex-math></inline-formula>m). BSC was computed using the reference phantom method, and robustness was assessed via the BSC standard deviation across ROIs. Results showed that, despite the lower B-mode resolution and longer correlation length between A-lines, volumetric estimation with a matrix probe offered comparable accuracy while enhancing robustness and resolution in the BSC map compared to the standard 2D estimation. These results could be beneficial for the analysis of complex heterogeneous media.\",\"PeriodicalId\":73301,\"journal\":{\"name\":\"IEEE open journal of ultrasonics, ferroelectrics, and frequency control\",\"volume\":\"5 \",\"pages\":\"119-122\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2025-07-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11079648\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE open journal of ultrasonics, ferroelectrics, and frequency control\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/11079648/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11079648/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
软组织后向散射系数(BSC)的评估在医学诊断中有许多应用。然而,电子噪声和空间变化经常影响BSC估计,需要在感兴趣区域(ROI)内进行空间平均,与b模式图像相比,这降低了空间分辨率。本研究使用矩阵探针探索3D BSC估计,通过允许更窄的roi而不失去鲁棒性来解决这种权衡。采用1024元矩阵探针(V8)和线性探针(L12-5、L22-8)在含Orgasol粒子(5、10、20~ $ mu $ m)的均相琼脂模型上进行了对比研究。采用参考模体法计算平衡计分卡,并通过roi之间的平衡计分卡标准差评估鲁棒性。结果表明,尽管b模式分辨率较低,a线之间的相关长度较长,但与标准2D估计相比,矩阵探针的体积估计在增强BSC图的鲁棒性和分辨率的同时提供了相当的精度。这些结果可用于复杂非均质介质的分析。
Volumetric Estimation of the Backscatter Coefficient With a Matrix Probe
Evaluation of the backscatter coefficient (BSC) from soft tissues has many applications for medical diagnosis. However, electronic noise and spatial variations often affect BSC estimation, requiring spatial averaging inside a region of interest (ROI) that reduces spatial resolution compared to the B-mode images. This study explores 3D BSC estimation using a matrix probes to address this trade-off by allowing narrower ROIs without losing robustness. A comparison study between a 1024-element matrix probe (V8) and two linear probes (L12-5, L22-8) was made on homogeneous agar-based phantoms with Orgasol particles (5, 10, and $20~\mu $ m). BSC was computed using the reference phantom method, and robustness was assessed via the BSC standard deviation across ROIs. Results showed that, despite the lower B-mode resolution and longer correlation length between A-lines, volumetric estimation with a matrix probe offered comparable accuracy while enhancing robustness and resolution in the BSC map compared to the standard 2D estimation. These results could be beneficial for the analysis of complex heterogeneous media.