小鼠性别和C57BL/6亚株对异氟醚和氯胺酮-噻嗪-乙酰丙嗪麻醉敏感性的影响。

Katharine P Tuohy, Anila R Tynan, Jovannah N Gerisma, James O Marx
{"title":"小鼠性别和C57BL/6亚株对异氟醚和氯胺酮-噻嗪-乙酰丙嗪麻醉敏感性的影响。","authors":"Katharine P Tuohy, Anila R Tynan, Jovannah N Gerisma, James O Marx","doi":"10.30802/AALAS-JAALAS-25-038","DOIUrl":null,"url":null,"abstract":"<p><p>Anesthesia is commonly performed with mice in the research setting. Standard doses of anesthetic drugs are typically recommended, without customization to strain, substrain, or sex. The purpose of this study was to evaluate C57BL/6 substrain and sex differences in response to isoflurane and ketamine/xylazine/acepromazine (KXA) injectable anesthesia. Female and male C57BL/6NTac, C57BL/6J, C57BL6/6NHsd, and C57BL/6NCrl mice were sourced from 4 different vendors. Isoflurane anesthesia trials were performed with a subset of the mice (n = 24) to determine the minimum alveolar concentration (MAC). Loss of righting reflex, total loss of righting time, time to loss of pedal withdrawal reflex, and total time at surgical plane were evaluated for mice (n = 64) administered 100 mg/kg ketamine, 10 mg/kg xylazine, and 1 mg/kg acepromazine by intraperitoneal injection. Heart rate, respiratory rate, and hemoglobin oxygen saturation (SpO2) were monitored throughout each anesthetic event. Isoflurane MAC was not affected by sex or substrain. In the KXA trials, male mice exhibited a longer duration of loss of righting reflex and remained at a surgical plane of anesthesia significantly longer than the female mice. No significant differences in substrain were detected in the depth or duration of anesthesia. Evaluation of physiologic parameters revealed differences in heart rate between substrains, with C57BL/6NHsd mice exhibiting significantly lower heart rates than the other 3 substrains during both isoflurane and KXA anesthesia. C57BL/6J mice had the highest heart rates during KXA anesthesia. These heart rate differences can impact clinical monitoring practices and are important to consider when selecting strains for study models, especially for cardiovascular studies. In conclusion, the male C57BL/6 mice exhibited a longer duration of anesthesia in response to KXA, while no substrain differences were detected for anesthetic depth or duration of either isoflurane or KXA anesthesia.</p>","PeriodicalId":94111,"journal":{"name":"Journal of the American Association for Laboratory Animal Science : JAALAS","volume":" ","pages":"1-10"},"PeriodicalIF":0.0000,"publicationDate":"2025-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Mouse (Mus musculus) Sex and C57BL/6 Substrain on Sensitivity to Isoflurane and Ketamine-Xylazine-Acepromazine Anesthesia.\",\"authors\":\"Katharine P Tuohy, Anila R Tynan, Jovannah N Gerisma, James O Marx\",\"doi\":\"10.30802/AALAS-JAALAS-25-038\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Anesthesia is commonly performed with mice in the research setting. Standard doses of anesthetic drugs are typically recommended, without customization to strain, substrain, or sex. The purpose of this study was to evaluate C57BL/6 substrain and sex differences in response to isoflurane and ketamine/xylazine/acepromazine (KXA) injectable anesthesia. Female and male C57BL/6NTac, C57BL/6J, C57BL6/6NHsd, and C57BL/6NCrl mice were sourced from 4 different vendors. Isoflurane anesthesia trials were performed with a subset of the mice (n = 24) to determine the minimum alveolar concentration (MAC). Loss of righting reflex, total loss of righting time, time to loss of pedal withdrawal reflex, and total time at surgical plane were evaluated for mice (n = 64) administered 100 mg/kg ketamine, 10 mg/kg xylazine, and 1 mg/kg acepromazine by intraperitoneal injection. Heart rate, respiratory rate, and hemoglobin oxygen saturation (SpO2) were monitored throughout each anesthetic event. Isoflurane MAC was not affected by sex or substrain. In the KXA trials, male mice exhibited a longer duration of loss of righting reflex and remained at a surgical plane of anesthesia significantly longer than the female mice. No significant differences in substrain were detected in the depth or duration of anesthesia. Evaluation of physiologic parameters revealed differences in heart rate between substrains, with C57BL/6NHsd mice exhibiting significantly lower heart rates than the other 3 substrains during both isoflurane and KXA anesthesia. C57BL/6J mice had the highest heart rates during KXA anesthesia. These heart rate differences can impact clinical monitoring practices and are important to consider when selecting strains for study models, especially for cardiovascular studies. In conclusion, the male C57BL/6 mice exhibited a longer duration of anesthesia in response to KXA, while no substrain differences were detected for anesthetic depth or duration of either isoflurane or KXA anesthesia.</p>\",\"PeriodicalId\":94111,\"journal\":{\"name\":\"Journal of the American Association for Laboratory Animal Science : JAALAS\",\"volume\":\" \",\"pages\":\"1-10\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the American Association for Laboratory Animal Science : JAALAS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30802/AALAS-JAALAS-25-038\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Association for Laboratory Animal Science : JAALAS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30802/AALAS-JAALAS-25-038","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在研究环境中,通常对小鼠进行麻醉。通常推荐使用标准剂量的麻醉药物,不针对毒株、亚毒株或性别进行定制。本研究的目的是评价C57BL/6亚株对异氟醚和氯胺酮/噻嗪/乙酰丙嗪(KXA)注射麻醉的反应及其性别差异。雌性和雄性C57BL/6NTac、C57BL/6J、C57BL6/6NHsd和C57BL/6NCrl小鼠来自4个不同的供应商。异氟醚麻醉试验在小鼠亚群(n = 24)中进行,以确定最低肺泡浓度(MAC)。对腹腔注射100 mg/kg氯胺酮、10 mg/kg噻嗪和1 mg/kg乙酰丙嗪的小鼠(n = 64)进行翻正反射丧失、翻正总时间丧失、到踏板退出反射丧失的时间以及手术平面总时间的评估。在每次麻醉过程中监测心率、呼吸频率和血红蛋白氧饱和度(SpO2)。异氟烷MAC不受性别和亚品系的影响。在KXA试验中,雄性小鼠比雌性小鼠表现出更长的翻正反射丧失时间,并且在手术麻醉平面上停留的时间明显更长。在麻醉的深度和持续时间上,亚张力没有明显的差异。生理参数的评估显示了亚品系之间心率的差异,C57BL/6NHsd小鼠在异氟醚和KXA麻醉下的心率明显低于其他3个亚品系。KXA麻醉时C57BL/6J小鼠心率最高。这些心率差异会影响临床监测实践,在选择研究模型的菌株时,特别是在心血管研究中,这是重要的考虑因素。综上所述,雄性C57BL/6小鼠对KXA的麻醉反应时间更长,而异氟醚和KXA麻醉的麻醉深度和麻醉时间没有亚种差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of Mouse (Mus musculus) Sex and C57BL/6 Substrain on Sensitivity to Isoflurane and Ketamine-Xylazine-Acepromazine Anesthesia.

Anesthesia is commonly performed with mice in the research setting. Standard doses of anesthetic drugs are typically recommended, without customization to strain, substrain, or sex. The purpose of this study was to evaluate C57BL/6 substrain and sex differences in response to isoflurane and ketamine/xylazine/acepromazine (KXA) injectable anesthesia. Female and male C57BL/6NTac, C57BL/6J, C57BL6/6NHsd, and C57BL/6NCrl mice were sourced from 4 different vendors. Isoflurane anesthesia trials were performed with a subset of the mice (n = 24) to determine the minimum alveolar concentration (MAC). Loss of righting reflex, total loss of righting time, time to loss of pedal withdrawal reflex, and total time at surgical plane were evaluated for mice (n = 64) administered 100 mg/kg ketamine, 10 mg/kg xylazine, and 1 mg/kg acepromazine by intraperitoneal injection. Heart rate, respiratory rate, and hemoglobin oxygen saturation (SpO2) were monitored throughout each anesthetic event. Isoflurane MAC was not affected by sex or substrain. In the KXA trials, male mice exhibited a longer duration of loss of righting reflex and remained at a surgical plane of anesthesia significantly longer than the female mice. No significant differences in substrain were detected in the depth or duration of anesthesia. Evaluation of physiologic parameters revealed differences in heart rate between substrains, with C57BL/6NHsd mice exhibiting significantly lower heart rates than the other 3 substrains during both isoflurane and KXA anesthesia. C57BL/6J mice had the highest heart rates during KXA anesthesia. These heart rate differences can impact clinical monitoring practices and are important to consider when selecting strains for study models, especially for cardiovascular studies. In conclusion, the male C57BL/6 mice exhibited a longer duration of anesthesia in response to KXA, while no substrain differences were detected for anesthetic depth or duration of either isoflurane or KXA anesthesia.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信