Lin Wang, Jingjie Wang, Shijiao Liu, Anlin Li, Haonan Sun, Xuelian Liu, Chunyang Wang
{"title":"设计了一种新型高速扫描振镜的结构和扫描控制策略","authors":"Lin Wang, Jingjie Wang, Shijiao Liu, Anlin Li, Haonan Sun, Xuelian Liu, Chunyang Wang","doi":"10.1016/j.ymssp.2025.113058","DOIUrl":null,"url":null,"abstract":"<div><div>Traditional galvanometers usually use optical sensors to achieve superior position accuracy. Due to the drawbacks of poor anti-interference characteristic and their poor accuracy at high temperature and during vibration, the anti-interference characteristic and high-precision positioning characteristic of galvanometers are limited. This paper proposes a new mechanical structure based on differential eddy current sensors. High-performance motion control is the core requirement of galvanometers, but there are uncertainties and nonlinear factors in motion-control systems that restrict the improvement in their performance. This study uses fractional order theory and active disturbance rejection controller to achieve high-speed motion-control strategy. The new type of scanning galvanometer is designed as the experimental platform to test the proposed strategy. The anti-interference characteristic of the vibrating galvanometer is tested under high temperature and vibration conditions. Build the fast circumferential scanning detection system experimental platform, using the high-speed swing of the scanning galvanometer to achieve compensated imaging. When the horizontal turntable speed is set at 210°/s and the scanning galvanometer speed is 516 degrees °/s, the 80 Hz frame rate can be achieved, maintaining a uniform linear range of 5 ms, and the system imaging is clear. The study verifies the performance improvement of the proposed strategy and method in terms of disturbance rejection.</div></div>","PeriodicalId":51124,"journal":{"name":"Mechanical Systems and Signal Processing","volume":"237 ","pages":"Article 113058"},"PeriodicalIF":8.9000,"publicationDate":"2025-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design of a new type of high-speed scanning galvanometer structure and scanning control strategy\",\"authors\":\"Lin Wang, Jingjie Wang, Shijiao Liu, Anlin Li, Haonan Sun, Xuelian Liu, Chunyang Wang\",\"doi\":\"10.1016/j.ymssp.2025.113058\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Traditional galvanometers usually use optical sensors to achieve superior position accuracy. Due to the drawbacks of poor anti-interference characteristic and their poor accuracy at high temperature and during vibration, the anti-interference characteristic and high-precision positioning characteristic of galvanometers are limited. This paper proposes a new mechanical structure based on differential eddy current sensors. High-performance motion control is the core requirement of galvanometers, but there are uncertainties and nonlinear factors in motion-control systems that restrict the improvement in their performance. This study uses fractional order theory and active disturbance rejection controller to achieve high-speed motion-control strategy. The new type of scanning galvanometer is designed as the experimental platform to test the proposed strategy. The anti-interference characteristic of the vibrating galvanometer is tested under high temperature and vibration conditions. Build the fast circumferential scanning detection system experimental platform, using the high-speed swing of the scanning galvanometer to achieve compensated imaging. When the horizontal turntable speed is set at 210°/s and the scanning galvanometer speed is 516 degrees °/s, the 80 Hz frame rate can be achieved, maintaining a uniform linear range of 5 ms, and the system imaging is clear. The study verifies the performance improvement of the proposed strategy and method in terms of disturbance rejection.</div></div>\",\"PeriodicalId\":51124,\"journal\":{\"name\":\"Mechanical Systems and Signal Processing\",\"volume\":\"237 \",\"pages\":\"Article 113058\"},\"PeriodicalIF\":8.9000,\"publicationDate\":\"2025-07-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Mechanical Systems and Signal Processing\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0888327025007599\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mechanical Systems and Signal Processing","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0888327025007599","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
Design of a new type of high-speed scanning galvanometer structure and scanning control strategy
Traditional galvanometers usually use optical sensors to achieve superior position accuracy. Due to the drawbacks of poor anti-interference characteristic and their poor accuracy at high temperature and during vibration, the anti-interference characteristic and high-precision positioning characteristic of galvanometers are limited. This paper proposes a new mechanical structure based on differential eddy current sensors. High-performance motion control is the core requirement of galvanometers, but there are uncertainties and nonlinear factors in motion-control systems that restrict the improvement in their performance. This study uses fractional order theory and active disturbance rejection controller to achieve high-speed motion-control strategy. The new type of scanning galvanometer is designed as the experimental platform to test the proposed strategy. The anti-interference characteristic of the vibrating galvanometer is tested under high temperature and vibration conditions. Build the fast circumferential scanning detection system experimental platform, using the high-speed swing of the scanning galvanometer to achieve compensated imaging. When the horizontal turntable speed is set at 210°/s and the scanning galvanometer speed is 516 degrees °/s, the 80 Hz frame rate can be achieved, maintaining a uniform linear range of 5 ms, and the system imaging is clear. The study verifies the performance improvement of the proposed strategy and method in terms of disturbance rejection.
期刊介绍:
Journal Name: Mechanical Systems and Signal Processing (MSSP)
Interdisciplinary Focus:
Mechanical, Aerospace, and Civil Engineering
Purpose:Reporting scientific advancements of the highest quality
Arising from new techniques in sensing, instrumentation, signal processing, modelling, and control of dynamic systems