Raymond R Tjandrawinata, Danang Agung Yunaidi, Yantirta Indra Kurniawan, Clarasintha Nindyatami, Ismail Dwi Saputro, Syifa Anugriani Aziswan, Vicky Achmad Ginanjar, Liana W Susanto
{"title":"空腹条件下坦索罗辛0.4 mg膜包膜缓释片在健康人体内的生物等效性","authors":"Raymond R Tjandrawinata, Danang Agung Yunaidi, Yantirta Indra Kurniawan, Clarasintha Nindyatami, Ismail Dwi Saputro, Syifa Anugriani Aziswan, Vicky Achmad Ginanjar, Liana W Susanto","doi":"10.5414/CP204708","DOIUrl":null,"url":null,"abstract":"<p><p>This open-label, randomized, single-dose, 4-period, 2-sequence, fully replicated study was conducted to evaluate the bioequivalence of tamsulosin 0.4 mg sustained-release film-coated tablet manufactured by PT Dexa Medica, Indonesia, and Harnal OCAS 0.4 mg prolonged-release tablet manufactured by Astellas Pharma Europe B.V., the Netherlands, imported by PT Combiphar, Indonesia, under fasting conditions in 28 healthy adult Indonesian males. Subjects were randomly assigned to receive the test formulation (1 single tablet of 0.4 mg) or the reference formulation (1 single tablet of 0.4 mg) orally in each of the 4 study periods, according to the full replicate design. Therefore, over the 4 complete periods, each subject received 2 administrations of the test formulation and 2 administrations of the reference formulation, with each administration separated by a 7-day washout period. The plasma concentration of tamsulosin from the blood samples was analyzed using validated ultra-performance liquid chromatography with tandem mass spectroscopy detection (UPLC-MS/MS), and pharmacokinetic parameters (AUC<sub>0-t</sub>, AUC<sub>0-∞</sub>, C<sub>max</sub>, t<sub>max</sub>, and T<sub>1/2</sub>) were calculated. The 90% confidence interval (CI) for the test/reference geometric mean ratio (GMR) of the AUC<sub>0-t</sub> was 80.2 - 98.4%, and for AUC<sub>0-∞</sub> it was 80.5 - 120.1%. The 90% CI GMR of C<sub>max</sub> was 89.3 - 107.7%. All parameters were within the 90% CI GMR acceptance criteria of 80.0 - 125.0%. The T<sub>1/2</sub> and t<sub>max</sub> of the 2 test drugs and the 2 reference drugs were not statistically different. There was no adverse effect observed during the study. Based on the study results, it was concluded that both tamsulosin formulations were bioequivalent and well tolerated.</p>","PeriodicalId":13963,"journal":{"name":"International journal of clinical pharmacology and therapeutics","volume":" ","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2025-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Bioequivalence of tamsulosin 0.4 mg film-coated sustained-release tablet formulations in healthy subjects under fasting conditions.\",\"authors\":\"Raymond R Tjandrawinata, Danang Agung Yunaidi, Yantirta Indra Kurniawan, Clarasintha Nindyatami, Ismail Dwi Saputro, Syifa Anugriani Aziswan, Vicky Achmad Ginanjar, Liana W Susanto\",\"doi\":\"10.5414/CP204708\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This open-label, randomized, single-dose, 4-period, 2-sequence, fully replicated study was conducted to evaluate the bioequivalence of tamsulosin 0.4 mg sustained-release film-coated tablet manufactured by PT Dexa Medica, Indonesia, and Harnal OCAS 0.4 mg prolonged-release tablet manufactured by Astellas Pharma Europe B.V., the Netherlands, imported by PT Combiphar, Indonesia, under fasting conditions in 28 healthy adult Indonesian males. Subjects were randomly assigned to receive the test formulation (1 single tablet of 0.4 mg) or the reference formulation (1 single tablet of 0.4 mg) orally in each of the 4 study periods, according to the full replicate design. Therefore, over the 4 complete periods, each subject received 2 administrations of the test formulation and 2 administrations of the reference formulation, with each administration separated by a 7-day washout period. The plasma concentration of tamsulosin from the blood samples was analyzed using validated ultra-performance liquid chromatography with tandem mass spectroscopy detection (UPLC-MS/MS), and pharmacokinetic parameters (AUC<sub>0-t</sub>, AUC<sub>0-∞</sub>, C<sub>max</sub>, t<sub>max</sub>, and T<sub>1/2</sub>) were calculated. The 90% confidence interval (CI) for the test/reference geometric mean ratio (GMR) of the AUC<sub>0-t</sub> was 80.2 - 98.4%, and for AUC<sub>0-∞</sub> it was 80.5 - 120.1%. The 90% CI GMR of C<sub>max</sub> was 89.3 - 107.7%. All parameters were within the 90% CI GMR acceptance criteria of 80.0 - 125.0%. The T<sub>1/2</sub> and t<sub>max</sub> of the 2 test drugs and the 2 reference drugs were not statistically different. There was no adverse effect observed during the study. Based on the study results, it was concluded that both tamsulosin formulations were bioequivalent and well tolerated.</p>\",\"PeriodicalId\":13963,\"journal\":{\"name\":\"International journal of clinical pharmacology and therapeutics\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2025-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of clinical pharmacology and therapeutics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5414/CP204708\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHARMACOLOGY & PHARMACY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of clinical pharmacology and therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5414/CP204708","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0
摘要
本研究采用开放标签、随机、单剂量、4期、2序列、完全重复的方法,评价印尼PT Dexa Medica公司生产的坦索罗辛0.4 mg缓释片和印尼PT Combiphar公司进口的荷兰Astellas Pharma Europe B.V公司生产的Harnal OCAS 0.4 mg缓释片在印度尼西亚28名健康成年男性空腹条件下的生物等效性。根据完全重复设计,受试者在4个研究期间随机接受试验制剂(1片0.4 mg)或参比制剂(1片0.4 mg)口服。因此,在4个完整的周期内,每个受试者接受2次试验制剂和2次参比制剂,每次给药间隔7天的洗脱期。采用经验证的超高效液相色谱串联质谱法(UPLC-MS/MS)分析血样中坦索罗辛的血药浓度,并计算药动学参数AUC0-t、AUC0-∞、Cmax、tmax和T1/2。AUC0-t的检验/参考几何平均比(GMR)的90%置信区间(CI)为80.2 ~ 98.4%,AUC0-∞的90%置信区间(CI)为80.5 ~ 120.1%。Cmax的90% CI GMR为89.3 ~ 107.7%。所有参数均在90% CI GMR可接受标准80.0 - 125.0%之内。2种试验药物与2种参比药物的T1/2、tmax差异无统计学意义。研究期间未观察到不良反应。根据研究结果,两种坦索罗辛制剂具有生物等效性和良好的耐受性。
Bioequivalence of tamsulosin 0.4 mg film-coated sustained-release tablet formulations in healthy subjects under fasting conditions.
This open-label, randomized, single-dose, 4-period, 2-sequence, fully replicated study was conducted to evaluate the bioequivalence of tamsulosin 0.4 mg sustained-release film-coated tablet manufactured by PT Dexa Medica, Indonesia, and Harnal OCAS 0.4 mg prolonged-release tablet manufactured by Astellas Pharma Europe B.V., the Netherlands, imported by PT Combiphar, Indonesia, under fasting conditions in 28 healthy adult Indonesian males. Subjects were randomly assigned to receive the test formulation (1 single tablet of 0.4 mg) or the reference formulation (1 single tablet of 0.4 mg) orally in each of the 4 study periods, according to the full replicate design. Therefore, over the 4 complete periods, each subject received 2 administrations of the test formulation and 2 administrations of the reference formulation, with each administration separated by a 7-day washout period. The plasma concentration of tamsulosin from the blood samples was analyzed using validated ultra-performance liquid chromatography with tandem mass spectroscopy detection (UPLC-MS/MS), and pharmacokinetic parameters (AUC0-t, AUC0-∞, Cmax, tmax, and T1/2) were calculated. The 90% confidence interval (CI) for the test/reference geometric mean ratio (GMR) of the AUC0-t was 80.2 - 98.4%, and for AUC0-∞ it was 80.5 - 120.1%. The 90% CI GMR of Cmax was 89.3 - 107.7%. All parameters were within the 90% CI GMR acceptance criteria of 80.0 - 125.0%. The T1/2 and tmax of the 2 test drugs and the 2 reference drugs were not statistically different. There was no adverse effect observed during the study. Based on the study results, it was concluded that both tamsulosin formulations were bioequivalent and well tolerated.
期刊介绍:
The International Journal of Clinical Pharmacology and Therapeutics appears monthly and publishes manuscripts containing original material with emphasis on the following topics: Clinical trials, Pharmacoepidemiology - Pharmacovigilance, Pharmacodynamics, Drug disposition and Pharmacokinetics, Quality assurance, Pharmacogenetics, Biotechnological drugs such as cytokines and recombinant antibiotics. Case reports on adverse reactions are also of interest.