药物浓度和ADA测定对滴度和信噪比评估及相关性的影响。

IF 1.8 4区 医学 Q3 BIOCHEMICAL RESEARCH METHODS
Bioanalysis Pub Date : 2025-06-01 Epub Date: 2025-07-14 DOI:10.1080/17576180.2025.2529146
Lili Guo, Kevin Carleton, Yong Jiang, Christopher Ehlinger
{"title":"药物浓度和ADA测定对滴度和信噪比评估及相关性的影响。","authors":"Lili Guo, Kevin Carleton, Yong Jiang, Christopher Ehlinger","doi":"10.1080/17576180.2025.2529146","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/aim: </strong>The three-tiered testing strategy for an anti-drug antibody (ADA) assay is a common practice for assessing the immunogenicity to therapeutic products. Efforts to streamline the ADA testing process led to proposals of using signal to noise (<i>S/N</i>) as a substitute for titer when determining ADA magnitude. This study aims to identify the critical factors that may influence the correlation of <i>S/N</i> and titer.</p><p><strong>Method/result: </strong>Experimental and clinical ADA datasets were examined to assess how drug concentration and the assay drug tolerance affect the measurement and correlation of <i>S/N</i> and titer. Under various experimental conditions the influence of drug on titer was minimal across a range of drug concentrations. However, drug presence affected the <i>S/N</i>, particularly when drug concentrations approached the assay drug tolerance. Clinical ADA datasets showed a moderate to strong correlation between <i>S/N</i> and titer, demonstrating similar patterns of drug impact on both measurements, as observed in the experimental data.</p><p><strong>Conclusion: </strong>The presence of drug in clinical samples and the drug tolerance of the ADA assay simultaneously influence the measurement and correlation of <i>S/N</i> and titer. The fold difference between drug tolerance and the maximum drug concentration in samples is a key factor in determining this correlation.</p>","PeriodicalId":8797,"journal":{"name":"Bioanalysis","volume":" ","pages":"787-793"},"PeriodicalIF":1.8000,"publicationDate":"2025-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12367090/pdf/","citationCount":"0","resultStr":"{\"title\":\"Impact of drug concentration and ADA assay drug tolerance on the assessment and correlation of titer and signal to noise.\",\"authors\":\"Lili Guo, Kevin Carleton, Yong Jiang, Christopher Ehlinger\",\"doi\":\"10.1080/17576180.2025.2529146\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background/aim: </strong>The three-tiered testing strategy for an anti-drug antibody (ADA) assay is a common practice for assessing the immunogenicity to therapeutic products. Efforts to streamline the ADA testing process led to proposals of using signal to noise (<i>S/N</i>) as a substitute for titer when determining ADA magnitude. This study aims to identify the critical factors that may influence the correlation of <i>S/N</i> and titer.</p><p><strong>Method/result: </strong>Experimental and clinical ADA datasets were examined to assess how drug concentration and the assay drug tolerance affect the measurement and correlation of <i>S/N</i> and titer. Under various experimental conditions the influence of drug on titer was minimal across a range of drug concentrations. However, drug presence affected the <i>S/N</i>, particularly when drug concentrations approached the assay drug tolerance. Clinical ADA datasets showed a moderate to strong correlation between <i>S/N</i> and titer, demonstrating similar patterns of drug impact on both measurements, as observed in the experimental data.</p><p><strong>Conclusion: </strong>The presence of drug in clinical samples and the drug tolerance of the ADA assay simultaneously influence the measurement and correlation of <i>S/N</i> and titer. The fold difference between drug tolerance and the maximum drug concentration in samples is a key factor in determining this correlation.</p>\",\"PeriodicalId\":8797,\"journal\":{\"name\":\"Bioanalysis\",\"volume\":\" \",\"pages\":\"787-793\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2025-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12367090/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioanalysis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/17576180.2025.2529146\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/7/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioanalysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/17576180.2025.2529146","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/7/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

背景/目的:抗药物抗体(ADA)检测的三层检测策略是评估治疗产品免疫原性的常用方法。简化ADA测试过程的努力导致了在确定ADA幅度时使用信噪比(S/N)代替滴度的建议。本研究旨在确定可能影响S/N与滴度相关性的关键因素。方法/结果:采用实验和临床ADA数据,评估药物浓度和测定药物耐受性如何影响S/N和滴度的测量及其相关性。在各种实验条件下,药物对滴度的影响在药物浓度范围内是最小的。然而,药物的存在影响S/N,特别是当药物浓度接近测定药物耐受性时。临床ADA数据集显示,S/N和滴度之间存在中等到强烈的相关性,正如实验数据中观察到的那样,药物对两种测量值的影响模式相似。结论:临床样品中药物的存在和ADA法的药物耐受性同时影响S/N和滴度的测定及其相关性。药物耐受性与样品中最大药物浓度之间的倍数差异是确定这种相关性的关键因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of drug concentration and ADA assay drug tolerance on the assessment and correlation of titer and signal to noise.

Background/aim: The three-tiered testing strategy for an anti-drug antibody (ADA) assay is a common practice for assessing the immunogenicity to therapeutic products. Efforts to streamline the ADA testing process led to proposals of using signal to noise (S/N) as a substitute for titer when determining ADA magnitude. This study aims to identify the critical factors that may influence the correlation of S/N and titer.

Method/result: Experimental and clinical ADA datasets were examined to assess how drug concentration and the assay drug tolerance affect the measurement and correlation of S/N and titer. Under various experimental conditions the influence of drug on titer was minimal across a range of drug concentrations. However, drug presence affected the S/N, particularly when drug concentrations approached the assay drug tolerance. Clinical ADA datasets showed a moderate to strong correlation between S/N and titer, demonstrating similar patterns of drug impact on both measurements, as observed in the experimental data.

Conclusion: The presence of drug in clinical samples and the drug tolerance of the ADA assay simultaneously influence the measurement and correlation of S/N and titer. The fold difference between drug tolerance and the maximum drug concentration in samples is a key factor in determining this correlation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Bioanalysis
Bioanalysis BIOCHEMICAL RESEARCH METHODS-CHEMISTRY, ANALYTICAL
CiteScore
3.30
自引率
16.70%
发文量
88
审稿时长
2 months
期刊介绍: Reliable data obtained from selective, sensitive and reproducible analysis of xenobiotics and biotics in biological samples is a fundamental and crucial part of every successful drug development program. The same principles can also apply to many other areas of research such as forensic science, toxicology and sports doping testing. The bioanalytical field incorporates sophisticated techniques linking sample preparation and advanced separations with MS and NMR detection systems, automation and robotics. Standards set by regulatory bodies regarding method development and validation increasingly define the boundaries between speed and quality. Bioanalysis is a progressive discipline for which the future holds many exciting opportunities to further reduce sample volumes, analysis cost and environmental impact, as well as to improve sensitivity, specificity, accuracy, efficiency, assay throughput, data quality, data handling and processing. The journal Bioanalysis focuses on the techniques and methods used for the detection or quantitative study of analytes in human or animal biological samples. Bioanalysis encourages the submission of articles describing forward-looking applications, including biosensors, microfluidics, miniaturized analytical devices, and new hyphenated and multi-dimensional techniques. Bioanalysis delivers essential information in concise, at-a-glance article formats. Key advances in the field are reported and analyzed by international experts, providing an authoritative but accessible forum for the modern bioanalyst.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信