沙特阿拉伯农村和偏远地区发展单机混合能源系统的最佳规模

Q1 Environmental Science
Mubarak Alanazi
{"title":"沙特阿拉伯农村和偏远地区发展单机混合能源系统的最佳规模","authors":"Mubarak Alanazi","doi":"10.1016/j.cscee.2025.101257","DOIUrl":null,"url":null,"abstract":"<div><div>The availability of energy and water, which are required for the activities of the main residents, is essential to the development of rural areas. The demand for power is rising as a result of the ongoing population growth and the desire to develop these isolated locations. However, the adoption of renewable energy sources increased as a result of the scarcity of fossil fuels in these isolated places and the expensive cost of grid extensions. To develop these isolated desert locations, a hybrid renewable energy system (HRES) consisting of a diesel generator (DG), battery (B), wind turbine (WT), and solar panel (PV) is proposed. Battery storage and diesel generators operate as backup supplies in a stand-alone system, working in combination with other hybrid renewable energy system components. The expected electricity demands for ten dwellings in a small rural community in Hafar Al Batin, Saudi Arabia, are provided by this system. The seasonal and daily load curves of the suggested community are assessed. This community needs an electrical load of 53 kW. The optimal hybrid energy system combination for the proposed site is determined using HOMER Software, harmonizing reliability, cost, and minimal use of DG sets. The simulation results indicate that, despite the significant potential of wind and solar energies at the selected site, it was not adequate for an independent wind turbine system and a PV system. Thus, a storage battery or another form of energy conversion, like a diesel generator, is required. The results demonstrated that the cost of energy (COE) produced by the optimal hybrid WT/PV/DG/B system is 0.213 $/kWh. The ideal system comprises 20 kW PV panels, 330 kW WT, 58 kW DG, and 158 batteries, which can meet the electric load. The net present cost (NPC) of this optimal system is $ 628,571. Including a storage capacity is essential in order to minimize how often the DG operates and the number of hours it runs.</div></div>","PeriodicalId":34388,"journal":{"name":"Case Studies in Chemical and Environmental Engineering","volume":"12 ","pages":"Article 101257"},"PeriodicalIF":0.0000,"publicationDate":"2025-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimal sizing of stand-alone hybrid energy system for development of rural and remote areas in Saudi Arabia\",\"authors\":\"Mubarak Alanazi\",\"doi\":\"10.1016/j.cscee.2025.101257\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The availability of energy and water, which are required for the activities of the main residents, is essential to the development of rural areas. The demand for power is rising as a result of the ongoing population growth and the desire to develop these isolated locations. However, the adoption of renewable energy sources increased as a result of the scarcity of fossil fuels in these isolated places and the expensive cost of grid extensions. To develop these isolated desert locations, a hybrid renewable energy system (HRES) consisting of a diesel generator (DG), battery (B), wind turbine (WT), and solar panel (PV) is proposed. Battery storage and diesel generators operate as backup supplies in a stand-alone system, working in combination with other hybrid renewable energy system components. The expected electricity demands for ten dwellings in a small rural community in Hafar Al Batin, Saudi Arabia, are provided by this system. The seasonal and daily load curves of the suggested community are assessed. This community needs an electrical load of 53 kW. The optimal hybrid energy system combination for the proposed site is determined using HOMER Software, harmonizing reliability, cost, and minimal use of DG sets. The simulation results indicate that, despite the significant potential of wind and solar energies at the selected site, it was not adequate for an independent wind turbine system and a PV system. Thus, a storage battery or another form of energy conversion, like a diesel generator, is required. The results demonstrated that the cost of energy (COE) produced by the optimal hybrid WT/PV/DG/B system is 0.213 $/kWh. The ideal system comprises 20 kW PV panels, 330 kW WT, 58 kW DG, and 158 batteries, which can meet the electric load. The net present cost (NPC) of this optimal system is $ 628,571. Including a storage capacity is essential in order to minimize how often the DG operates and the number of hours it runs.</div></div>\",\"PeriodicalId\":34388,\"journal\":{\"name\":\"Case Studies in Chemical and Environmental Engineering\",\"volume\":\"12 \",\"pages\":\"Article 101257\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-07-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Case Studies in Chemical and Environmental Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666016425001641\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Environmental Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Studies in Chemical and Environmental Engineering","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666016425001641","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Environmental Science","Score":null,"Total":0}
引用次数: 0

摘要

主要居民活动所需的能源和水的供应对农村地区的发展至关重要。由于人口的持续增长和开发这些偏远地区的愿望,对电力的需求正在上升。然而,由于这些偏远地区化石燃料的稀缺和电网扩展的昂贵成本,可再生能源的采用有所增加。为了开发这些孤立的沙漠地区,提出了一种由柴油发电机(DG)、电池(B)、风力涡轮机(WT)和太阳能电池板(PV)组成的混合可再生能源系统(HRES)。电池存储和柴油发电机在独立系统中作为备用电源,与其他混合可再生能源系统组件一起工作。该系统可满足沙特阿拉伯Hafar Al Batin一个小型农村社区10户住宅的预期用电需求。评估了建议社区的季节和日负荷曲线。这个社区需要53千瓦的电力负荷。使用HOMER软件确定拟建站点的最佳混合能源系统组合,协调可靠性、成本和DG机组的最小使用。仿真结果表明,尽管所选场地的风能和太阳能潜力巨大,但对于独立的风力发电系统和光伏发电系统来说,这是不够的。因此,需要一个蓄电池或另一种形式的能量转换,如柴油发电机。结果表明,最优的WT/PV/DG/B混合系统产生的能量成本(COE)为0.213美元/千瓦时。理想的系统包括20千瓦的光伏板,330千瓦的WT, 58千瓦的DG和158个电池,可以满足电力负荷。该最优系统的净当前成本(NPC)为628,571美元。为了尽量减少DG运行的频率和运行的小时数,包括存储容量是必不可少的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimal sizing of stand-alone hybrid energy system for development of rural and remote areas in Saudi Arabia
The availability of energy and water, which are required for the activities of the main residents, is essential to the development of rural areas. The demand for power is rising as a result of the ongoing population growth and the desire to develop these isolated locations. However, the adoption of renewable energy sources increased as a result of the scarcity of fossil fuels in these isolated places and the expensive cost of grid extensions. To develop these isolated desert locations, a hybrid renewable energy system (HRES) consisting of a diesel generator (DG), battery (B), wind turbine (WT), and solar panel (PV) is proposed. Battery storage and diesel generators operate as backup supplies in a stand-alone system, working in combination with other hybrid renewable energy system components. The expected electricity demands for ten dwellings in a small rural community in Hafar Al Batin, Saudi Arabia, are provided by this system. The seasonal and daily load curves of the suggested community are assessed. This community needs an electrical load of 53 kW. The optimal hybrid energy system combination for the proposed site is determined using HOMER Software, harmonizing reliability, cost, and minimal use of DG sets. The simulation results indicate that, despite the significant potential of wind and solar energies at the selected site, it was not adequate for an independent wind turbine system and a PV system. Thus, a storage battery or another form of energy conversion, like a diesel generator, is required. The results demonstrated that the cost of energy (COE) produced by the optimal hybrid WT/PV/DG/B system is 0.213 $/kWh. The ideal system comprises 20 kW PV panels, 330 kW WT, 58 kW DG, and 158 batteries, which can meet the electric load. The net present cost (NPC) of this optimal system is $ 628,571. Including a storage capacity is essential in order to minimize how often the DG operates and the number of hours it runs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Case Studies in Chemical and Environmental Engineering
Case Studies in Chemical and Environmental Engineering Engineering-Engineering (miscellaneous)
CiteScore
9.20
自引率
0.00%
发文量
103
审稿时长
40 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信