低成本电化学生物传感器对人血清中KLK4的高灵敏度和选择性检测。

IF 1.4 4区 化学 Q3 CHEMISTRY, MULTIDISCIPLINARY
Turkish Journal of Chemistry Pub Date : 2025-04-29 eCollection Date: 2025-01-01 DOI:10.55730/1300-0527.3737
Elif Burcu Aydin
{"title":"低成本电化学生物传感器对人血清中KLK4的高灵敏度和选择性检测。","authors":"Elif Burcu Aydin","doi":"10.55730/1300-0527.3737","DOIUrl":null,"url":null,"abstract":"<p><p>An ultrasensitive impedimetric immunosensor was fabricated using a poly(glycidyl methacrylate) (PGMA) polymer-covered indium tin oxide (ITO) platform for the quantification of kallikrein 4 (KLK4), an important prostate cancer biomarker. PGMA had suitable biocompatibility and nontoxicity for loading of antiKLK4 antibodies on the ITO substrate surface. Anti-KLK4 biomolecules were directly attached to the PGMA-covered electrode surface via epoxy groups of the PGMA polymer. The preparation method for the PGMA matrix-modified electrode was simple and inexpensive. The proposed biosensor immobilization layers coated on the ITO electrode were characterized with electrochemical techniques. The experimental parameters that affect biosensor response were optimized, and the suggested sensor showed a linear response from 0.04 pg/mL to 8 pg/mL with a low detection limit (LOD) of 12.21 fg/mL. Moreover, it had acceptable stability, reproducibility, and repeatability. Additionally, the disposable biosensor offered excellent reliability and accuracy in KLK4 analysis, suggesting that it could be used as an alternative technique in clinical diagnosis.</p>","PeriodicalId":23367,"journal":{"name":"Turkish Journal of Chemistry","volume":"49 3","pages":"382-393"},"PeriodicalIF":1.4000,"publicationDate":"2025-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12253971/pdf/","citationCount":"0","resultStr":"{\"title\":\"Highly sensitive and selective detection of KLK4 in human serum with a low-cost electrochemical biosensor.\",\"authors\":\"Elif Burcu Aydin\",\"doi\":\"10.55730/1300-0527.3737\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>An ultrasensitive impedimetric immunosensor was fabricated using a poly(glycidyl methacrylate) (PGMA) polymer-covered indium tin oxide (ITO) platform for the quantification of kallikrein 4 (KLK4), an important prostate cancer biomarker. PGMA had suitable biocompatibility and nontoxicity for loading of antiKLK4 antibodies on the ITO substrate surface. Anti-KLK4 biomolecules were directly attached to the PGMA-covered electrode surface via epoxy groups of the PGMA polymer. The preparation method for the PGMA matrix-modified electrode was simple and inexpensive. The proposed biosensor immobilization layers coated on the ITO electrode were characterized with electrochemical techniques. The experimental parameters that affect biosensor response were optimized, and the suggested sensor showed a linear response from 0.04 pg/mL to 8 pg/mL with a low detection limit (LOD) of 12.21 fg/mL. Moreover, it had acceptable stability, reproducibility, and repeatability. Additionally, the disposable biosensor offered excellent reliability and accuracy in KLK4 analysis, suggesting that it could be used as an alternative technique in clinical diagnosis.</p>\",\"PeriodicalId\":23367,\"journal\":{\"name\":\"Turkish Journal of Chemistry\",\"volume\":\"49 3\",\"pages\":\"382-393\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-04-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12253971/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Turkish Journal of Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.55730/1300-0527.3737\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.55730/1300-0527.3737","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

利用聚甲基丙烯酸甘油酯(PGMA)聚合物覆盖的氧化铟锡(ITO)平台制备了一种超灵敏的阻抗免疫传感器,用于定量前列腺癌重要生物标志物钾化因子4 (KLK4)。PGMA具有良好的生物相容性和无毒性,可在ITO底物表面负载抗klk4抗体。抗klk4生物分子通过PGMA聚合物的环氧基团直接附着在PGMA覆盖的电极表面。该电极制备方法简单,成本低廉。利用电化学技术对所制备的生物传感器固定化层进行了表征。对影响传感器响应的实验参数进行了优化,该传感器在0.04 ~ 8 pg/mL范围内呈线性响应,低检出限为12.21 fg/mL。此外,它具有可接受的稳定性、再现性和可重复性。此外,一次性生物传感器在KLK4分析中提供了出色的可靠性和准确性,表明它可以作为临床诊断的替代技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Highly sensitive and selective detection of KLK4 in human serum with a low-cost electrochemical biosensor.

An ultrasensitive impedimetric immunosensor was fabricated using a poly(glycidyl methacrylate) (PGMA) polymer-covered indium tin oxide (ITO) platform for the quantification of kallikrein 4 (KLK4), an important prostate cancer biomarker. PGMA had suitable biocompatibility and nontoxicity for loading of antiKLK4 antibodies on the ITO substrate surface. Anti-KLK4 biomolecules were directly attached to the PGMA-covered electrode surface via epoxy groups of the PGMA polymer. The preparation method for the PGMA matrix-modified electrode was simple and inexpensive. The proposed biosensor immobilization layers coated on the ITO electrode were characterized with electrochemical techniques. The experimental parameters that affect biosensor response were optimized, and the suggested sensor showed a linear response from 0.04 pg/mL to 8 pg/mL with a low detection limit (LOD) of 12.21 fg/mL. Moreover, it had acceptable stability, reproducibility, and repeatability. Additionally, the disposable biosensor offered excellent reliability and accuracy in KLK4 analysis, suggesting that it could be used as an alternative technique in clinical diagnosis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Turkish Journal of Chemistry
Turkish Journal of Chemistry 化学-工程:化工
CiteScore
2.40
自引率
7.10%
发文量
87
审稿时长
3 months
期刊介绍: The Turkish Journal of Chemistry is a bimonthly multidisciplinary journal published by the Scientific and Technological Research Council of Turkey (TÜBİTAK). The journal is dedicated to dissemination of knowledge in all disciplines of chemistry (organic, inorganic, physical, polymeric, technical, theoretical and analytical chemistry) as well as research at the interface with other sciences especially in chemical engineering where molecular aspects are key to the findings. The journal accepts English-language original manuscripts and contribution is open to researchers of all nationalities. The journal publishes refereed original papers, reviews, letters to editor and issues devoted to special fields. All manuscripts are peer-reviewed and electronic processing ensures accurate reproduction of text and data, plus publication times as short as possible.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信