{"title":"基于刷式聚合物功能化一次性电极的智能电化学生物传感器检测p53生物标志物。","authors":"Muhammet Aydin","doi":"10.55730/1300-0527.3736","DOIUrl":null,"url":null,"abstract":"<p><p>A label-less impedimetric biosensor modified with poly(thiophene)-graft-poly(glycidyl methacrylate) polymer (PThi-g-PGM) was manufactured for p53 protein quantification in human serum samples. In this study, PThi-g-PGM polymer was synthesized, and this polymer matrix was coated using the spin-coating technique on the single-use indium tin oxide (ITO) substrate for anti-p53 antibody immobilization. The anti-p53 antibodies with high affinity for p53 proteins were covalently attached onto the PThi-g-PGM-coated electrode surface. In addition, the affinity of anti-p53 for the p53 protein was monitored at a constant frequency. Under optimized conditions, the impedimetric changes were linearly related to the p53 concentrations, ranging from 0.05 to 15 pg/mL with a low detection limit of 15.9 fg/mL. This biosensor had desirable storage stability, acceptable repeatability, and high reproducibility. Moreover, this impedimetric biosensor could be regenerated through an acidic treatment procedure. Additionally, the suggested biosensor successfully detected the p53 antigen in human serum samples, and good recycling rates (98.41%-109.32%) were found. In summary, the proposed immunosensor may be a powerful tool for the analysis of the p53 protein for early detection of cancer biomarkers.</p>","PeriodicalId":23367,"journal":{"name":"Turkish Journal of Chemistry","volume":"49 3","pages":"371-381"},"PeriodicalIF":1.4000,"publicationDate":"2025-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12253966/pdf/","citationCount":"0","resultStr":"{\"title\":\"Determination of p53 biomarker with a smart electrochemical biosensor based on brush polymer-functionalized disposable electrode.\",\"authors\":\"Muhammet Aydin\",\"doi\":\"10.55730/1300-0527.3736\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A label-less impedimetric biosensor modified with poly(thiophene)-graft-poly(glycidyl methacrylate) polymer (PThi-g-PGM) was manufactured for p53 protein quantification in human serum samples. In this study, PThi-g-PGM polymer was synthesized, and this polymer matrix was coated using the spin-coating technique on the single-use indium tin oxide (ITO) substrate for anti-p53 antibody immobilization. The anti-p53 antibodies with high affinity for p53 proteins were covalently attached onto the PThi-g-PGM-coated electrode surface. In addition, the affinity of anti-p53 for the p53 protein was monitored at a constant frequency. Under optimized conditions, the impedimetric changes were linearly related to the p53 concentrations, ranging from 0.05 to 15 pg/mL with a low detection limit of 15.9 fg/mL. This biosensor had desirable storage stability, acceptable repeatability, and high reproducibility. Moreover, this impedimetric biosensor could be regenerated through an acidic treatment procedure. Additionally, the suggested biosensor successfully detected the p53 antigen in human serum samples, and good recycling rates (98.41%-109.32%) were found. In summary, the proposed immunosensor may be a powerful tool for the analysis of the p53 protein for early detection of cancer biomarkers.</p>\",\"PeriodicalId\":23367,\"journal\":{\"name\":\"Turkish Journal of Chemistry\",\"volume\":\"49 3\",\"pages\":\"371-381\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-04-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12253966/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Turkish Journal of Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.55730/1300-0527.3736\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.55730/1300-0527.3736","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Determination of p53 biomarker with a smart electrochemical biosensor based on brush polymer-functionalized disposable electrode.
A label-less impedimetric biosensor modified with poly(thiophene)-graft-poly(glycidyl methacrylate) polymer (PThi-g-PGM) was manufactured for p53 protein quantification in human serum samples. In this study, PThi-g-PGM polymer was synthesized, and this polymer matrix was coated using the spin-coating technique on the single-use indium tin oxide (ITO) substrate for anti-p53 antibody immobilization. The anti-p53 antibodies with high affinity for p53 proteins were covalently attached onto the PThi-g-PGM-coated electrode surface. In addition, the affinity of anti-p53 for the p53 protein was monitored at a constant frequency. Under optimized conditions, the impedimetric changes were linearly related to the p53 concentrations, ranging from 0.05 to 15 pg/mL with a low detection limit of 15.9 fg/mL. This biosensor had desirable storage stability, acceptable repeatability, and high reproducibility. Moreover, this impedimetric biosensor could be regenerated through an acidic treatment procedure. Additionally, the suggested biosensor successfully detected the p53 antigen in human serum samples, and good recycling rates (98.41%-109.32%) were found. In summary, the proposed immunosensor may be a powerful tool for the analysis of the p53 protein for early detection of cancer biomarkers.
期刊介绍:
The Turkish Journal of Chemistry is a bimonthly multidisciplinary journal published by the Scientific and Technological Research Council of Turkey (TÜBİTAK).
The journal is dedicated to dissemination of knowledge in all disciplines of chemistry (organic, inorganic, physical, polymeric, technical, theoretical and analytical chemistry) as well as research at the interface with other sciences especially in chemical engineering where molecular aspects are key to the findings.
The journal accepts English-language original manuscripts and contribution is open to researchers of all nationalities.
The journal publishes refereed original papers, reviews, letters to editor and issues devoted to special fields.
All manuscripts are peer-reviewed and electronic processing ensures accurate reproduction of text and data, plus publication times as short as possible.