增强氮化碳中单原子分散钴过氧化物酶样活性的非发光系统化学发光信号检测谷胱甘肽

IF 5.6 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Zhiqiang Wang , Suxing Jiao , Yingzi Liu, Xulin Liu, Jing Wu
{"title":"增强氮化碳中单原子分散钴过氧化物酶样活性的非发光系统化学发光信号检测谷胱甘肽","authors":"Zhiqiang Wang ,&nbsp;Suxing Jiao ,&nbsp;Yingzi Liu,&nbsp;Xulin Liu,&nbsp;Jing Wu","doi":"10.1016/j.talanta.2025.128580","DOIUrl":null,"url":null,"abstract":"<div><div>Chemiluminescence (CL) analysis is regarded as a significant analytical tool due to its advantages, including no background interference, high sensitivity, easy operation, and cost-effectiveness. However, low emission intensity hinders its wide application. Therefore, it is necessary to develop sensitizers to enhance CL performance. In this work, one kind of single-atom catalysts (SACs) was prepared by atomically dispersing Co atoms on carbon nitride (Co–C<sub>3</sub>N<sub>4</sub> SACs) and applied in enhancing the CL intensity of NaHSO<sub>3</sub>–H<sub>2</sub>O<sub>2</sub> system for 107 times. The mechanism for CL enhancement of Co–C<sub>3</sub>N<sub>4</sub> SACs was studied by systematic experiments and theoretic calculation. Co–C<sub>3</sub>N<sub>4</sub> SACs exhibited strong peroxidase-like activity in H<sub>2</sub>O<sub>2</sub> decomposition, generating reactive oxygen species (ROS) as the key step for CL signal enhancement. The constructed Co–C<sub>3</sub>N<sub>4</sub> SACs-NaHSO<sub>3</sub>-H<sub>2</sub>O<sub>2</sub> CL system was utilized for the detection of glutathione (GSH), demonstrating a linear range of 10 μM–500 μM and a good linear relationship (<em>R</em><sup>2</sup> = 0.9978). This approach was successfully applied in detecting GSH in human serum, demonstrating excellent recoveries and repeatability. Our work has extended the application of SACs in non-luminol CL system and explored their capability in developing CL sensors.</div></div>","PeriodicalId":435,"journal":{"name":"Talanta","volume":"297 ","pages":"Article 128580"},"PeriodicalIF":5.6000,"publicationDate":"2025-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Enhanced peroxidase-like activity of single-atom dispersed cobalt in carbon nitride for glutathione detection via chemiluminescence signals of non-luminol system\",\"authors\":\"Zhiqiang Wang ,&nbsp;Suxing Jiao ,&nbsp;Yingzi Liu,&nbsp;Xulin Liu,&nbsp;Jing Wu\",\"doi\":\"10.1016/j.talanta.2025.128580\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Chemiluminescence (CL) analysis is regarded as a significant analytical tool due to its advantages, including no background interference, high sensitivity, easy operation, and cost-effectiveness. However, low emission intensity hinders its wide application. Therefore, it is necessary to develop sensitizers to enhance CL performance. In this work, one kind of single-atom catalysts (SACs) was prepared by atomically dispersing Co atoms on carbon nitride (Co–C<sub>3</sub>N<sub>4</sub> SACs) and applied in enhancing the CL intensity of NaHSO<sub>3</sub>–H<sub>2</sub>O<sub>2</sub> system for 107 times. The mechanism for CL enhancement of Co–C<sub>3</sub>N<sub>4</sub> SACs was studied by systematic experiments and theoretic calculation. Co–C<sub>3</sub>N<sub>4</sub> SACs exhibited strong peroxidase-like activity in H<sub>2</sub>O<sub>2</sub> decomposition, generating reactive oxygen species (ROS) as the key step for CL signal enhancement. The constructed Co–C<sub>3</sub>N<sub>4</sub> SACs-NaHSO<sub>3</sub>-H<sub>2</sub>O<sub>2</sub> CL system was utilized for the detection of glutathione (GSH), demonstrating a linear range of 10 μM–500 μM and a good linear relationship (<em>R</em><sup>2</sup> = 0.9978). This approach was successfully applied in detecting GSH in human serum, demonstrating excellent recoveries and repeatability. Our work has extended the application of SACs in non-luminol CL system and explored their capability in developing CL sensors.</div></div>\",\"PeriodicalId\":435,\"journal\":{\"name\":\"Talanta\",\"volume\":\"297 \",\"pages\":\"Article 128580\"},\"PeriodicalIF\":5.6000,\"publicationDate\":\"2025-07-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Talanta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0039914025010707\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0039914025010707","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

化学发光分析以其无背景干扰、灵敏度高、操作简便、经济高效等优点被认为是一种重要的分析工具。然而,低排放强度阻碍了其广泛应用。因此,有必要开发增敏剂来提高CL性能。本文将Co原子原子分散在氮化碳(Co - c3n4 SACs)上,制备了一种单原子催化剂(SACs),并将其用于提高NaHSO3-H2O2体系CL强度107倍。通过系统的实验和理论计算,研究了Co-C3N4 SACs的CL增强机理。Co-C3N4 SACs在H2O2分解中表现出较强的过氧化物酶样活性,产生活性氧(ROS)是CL信号增强的关键步骤。构建的Co-C3N4 SACs-NaHSO3-H2O2 CL体系用于谷胱甘肽(GSH)的检测,线性范围为10 μM - 500 μM,线性关系良好(R2 = 0.9978)。该方法已成功应用于人血清中谷胱甘肽的检测,具有良好的回收率和重复性。我们的工作扩展了SACs在非鲁米诺CL系统中的应用,并探索了SACs在CL传感器中的应用能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Enhanced peroxidase-like activity of single-atom dispersed cobalt in carbon nitride for glutathione detection via chemiluminescence signals of non-luminol system

Enhanced peroxidase-like activity of single-atom dispersed cobalt in carbon nitride for glutathione detection via chemiluminescence signals of non-luminol system
Chemiluminescence (CL) analysis is regarded as a significant analytical tool due to its advantages, including no background interference, high sensitivity, easy operation, and cost-effectiveness. However, low emission intensity hinders its wide application. Therefore, it is necessary to develop sensitizers to enhance CL performance. In this work, one kind of single-atom catalysts (SACs) was prepared by atomically dispersing Co atoms on carbon nitride (Co–C3N4 SACs) and applied in enhancing the CL intensity of NaHSO3–H2O2 system for 107 times. The mechanism for CL enhancement of Co–C3N4 SACs was studied by systematic experiments and theoretic calculation. Co–C3N4 SACs exhibited strong peroxidase-like activity in H2O2 decomposition, generating reactive oxygen species (ROS) as the key step for CL signal enhancement. The constructed Co–C3N4 SACs-NaHSO3-H2O2 CL system was utilized for the detection of glutathione (GSH), demonstrating a linear range of 10 μM–500 μM and a good linear relationship (R2 = 0.9978). This approach was successfully applied in detecting GSH in human serum, demonstrating excellent recoveries and repeatability. Our work has extended the application of SACs in non-luminol CL system and explored their capability in developing CL sensors.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Talanta
Talanta 化学-分析化学
CiteScore
12.30
自引率
4.90%
发文量
861
审稿时长
29 days
期刊介绍: Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome. Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信