Andrea Santamaría-Laorden, Alicia Martínez Marugán, Cristina Andreu-Vázquez, Jaime Orejas-Pérez
{"title":"使用摄影测量算法和智能手机应用程序的完整弓种植体捕获:一项体外研究","authors":"Andrea Santamaría-Laorden, Alicia Martínez Marugán, Cristina Andreu-Vázquez, Jaime Orejas-Pérez","doi":"10.1016/j.jdent.2025.105969","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>To compare the accuracy of complete arch implant capture using two extraoral photogrammetry (PG) systems (PIC system® and PIC app®).</div></div><div><h3>Methods</h3><div>An edentulous cast with six multiunit abutment (MUA) analogs was digitised and 30 complete arch implant captures were performed by each PG system. Euclidean linear and angular measurements were obtained on the digitised reference model with a coordinate measuring machine (CMM) and were used to compare the discrepancies with the same measurements obtained using the PG devices. The Mann–Withney U test was used to analyse the trueness data, and the Levene test was used to analyse the precision values (α=0.05).</div></div><div><h3>Results</h3><div>The mean ± standard deviation results for the distance and angulation measurements obtained using the PIC system and PIC app, respectively (18.21 ± 12.21 μm and 0.10 ± 0.07 degrees, and 30.92 ± 20.88 μm and 0.16 ± 0.09 degrees, respectively). The mean differences between the PIC app® and PIC system® were 12.70 μm (95 % confidence interval [CI]: 10.47, 14.94; <em>p</em> < 0.001) and 0.07 degrees (95 % CI: 0.05, 0.07; <em>p</em> < 0.001) for the Euclidean linear and angular measurements, respectively. The PIC system® demonstrated a greater precision (lower variance, <em>p</em> = 0.035) for linear measurements; however, both extraoral PG systems exhibited similar precision (equal variances) for angular measurements (<em>p</em> = 0.112).</div></div><div><h3>Conclusions</h3><div>PIC system® exhibited greater trueness for linear and angular measurements and linear precision. However, the impact of these statistically significant differences may not be clinically relevant.</div></div><div><h3>Statement of Clinical Relevance</h3><div>The PIC system® has been reported as an accurate PG method for recording the three-dimensional implant positions in complete arch prostheses; however, high equipment costs limit its widespread adoption. With the PIC app®, smartphones provide the democratisation of the PIC system® using an accurate and cost-effective approach.</div></div>","PeriodicalId":15585,"journal":{"name":"Journal of dentistry","volume":"161 ","pages":"Article 105969"},"PeriodicalIF":4.8000,"publicationDate":"2025-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Complete arch implant capture using a photogrammetry algorithm and smartphone app: An in vitro study\",\"authors\":\"Andrea Santamaría-Laorden, Alicia Martínez Marugán, Cristina Andreu-Vázquez, Jaime Orejas-Pérez\",\"doi\":\"10.1016/j.jdent.2025.105969\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><div>To compare the accuracy of complete arch implant capture using two extraoral photogrammetry (PG) systems (PIC system® and PIC app®).</div></div><div><h3>Methods</h3><div>An edentulous cast with six multiunit abutment (MUA) analogs was digitised and 30 complete arch implant captures were performed by each PG system. Euclidean linear and angular measurements were obtained on the digitised reference model with a coordinate measuring machine (CMM) and were used to compare the discrepancies with the same measurements obtained using the PG devices. The Mann–Withney U test was used to analyse the trueness data, and the Levene test was used to analyse the precision values (α=0.05).</div></div><div><h3>Results</h3><div>The mean ± standard deviation results for the distance and angulation measurements obtained using the PIC system and PIC app, respectively (18.21 ± 12.21 μm and 0.10 ± 0.07 degrees, and 30.92 ± 20.88 μm and 0.16 ± 0.09 degrees, respectively). The mean differences between the PIC app® and PIC system® were 12.70 μm (95 % confidence interval [CI]: 10.47, 14.94; <em>p</em> < 0.001) and 0.07 degrees (95 % CI: 0.05, 0.07; <em>p</em> < 0.001) for the Euclidean linear and angular measurements, respectively. The PIC system® demonstrated a greater precision (lower variance, <em>p</em> = 0.035) for linear measurements; however, both extraoral PG systems exhibited similar precision (equal variances) for angular measurements (<em>p</em> = 0.112).</div></div><div><h3>Conclusions</h3><div>PIC system® exhibited greater trueness for linear and angular measurements and linear precision. However, the impact of these statistically significant differences may not be clinically relevant.</div></div><div><h3>Statement of Clinical Relevance</h3><div>The PIC system® has been reported as an accurate PG method for recording the three-dimensional implant positions in complete arch prostheses; however, high equipment costs limit its widespread adoption. With the PIC app®, smartphones provide the democratisation of the PIC system® using an accurate and cost-effective approach.</div></div>\",\"PeriodicalId\":15585,\"journal\":{\"name\":\"Journal of dentistry\",\"volume\":\"161 \",\"pages\":\"Article 105969\"},\"PeriodicalIF\":4.8000,\"publicationDate\":\"2025-07-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0300571225004130\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0300571225004130","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Complete arch implant capture using a photogrammetry algorithm and smartphone app: An in vitro study
Objective
To compare the accuracy of complete arch implant capture using two extraoral photogrammetry (PG) systems (PIC system® and PIC app®).
Methods
An edentulous cast with six multiunit abutment (MUA) analogs was digitised and 30 complete arch implant captures were performed by each PG system. Euclidean linear and angular measurements were obtained on the digitised reference model with a coordinate measuring machine (CMM) and were used to compare the discrepancies with the same measurements obtained using the PG devices. The Mann–Withney U test was used to analyse the trueness data, and the Levene test was used to analyse the precision values (α=0.05).
Results
The mean ± standard deviation results for the distance and angulation measurements obtained using the PIC system and PIC app, respectively (18.21 ± 12.21 μm and 0.10 ± 0.07 degrees, and 30.92 ± 20.88 μm and 0.16 ± 0.09 degrees, respectively). The mean differences between the PIC app® and PIC system® were 12.70 μm (95 % confidence interval [CI]: 10.47, 14.94; p < 0.001) and 0.07 degrees (95 % CI: 0.05, 0.07; p < 0.001) for the Euclidean linear and angular measurements, respectively. The PIC system® demonstrated a greater precision (lower variance, p = 0.035) for linear measurements; however, both extraoral PG systems exhibited similar precision (equal variances) for angular measurements (p = 0.112).
Conclusions
PIC system® exhibited greater trueness for linear and angular measurements and linear precision. However, the impact of these statistically significant differences may not be clinically relevant.
Statement of Clinical Relevance
The PIC system® has been reported as an accurate PG method for recording the three-dimensional implant positions in complete arch prostheses; however, high equipment costs limit its widespread adoption. With the PIC app®, smartphones provide the democratisation of the PIC system® using an accurate and cost-effective approach.
期刊介绍:
The Journal of Dentistry has an open access mirror journal The Journal of Dentistry: X, sharing the same aims and scope, editorial team, submission system and rigorous peer review.
The Journal of Dentistry is the leading international dental journal within the field of Restorative Dentistry. Placing an emphasis on publishing novel and high-quality research papers, the Journal aims to influence the practice of dentistry at clinician, research, industry and policy-maker level on an international basis.
Topics covered include the management of dental disease, periodontology, endodontology, operative dentistry, fixed and removable prosthodontics, dental biomaterials science, long-term clinical trials including epidemiology and oral health, technology transfer of new scientific instrumentation or procedures, as well as clinically relevant oral biology and translational research.
The Journal of Dentistry will publish original scientific research papers including short communications. It is also interested in publishing review articles and leaders in themed areas which will be linked to new scientific research. Conference proceedings are also welcome and expressions of interest should be communicated to the Editor.