热循环和漂白对整体CAD-CAM牙科陶瓷颜色稳定性和亮度的影响。

Mohammadjavad Shirani, Zahra Naghibeiranvand, Maryam Emami, Kamran Azadbakht
{"title":"热循环和漂白对整体CAD-CAM牙科陶瓷颜色稳定性和亮度的影响。","authors":"Mohammadjavad Shirani, Zahra Naghibeiranvand, Maryam Emami, Kamran Azadbakht","doi":"10.11607/ijp.9429","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this in vitro study was to evaluate the effect of coffee thermocycling and carbamide peroxide bleaching on the color stability and lightness of monolithic CAD-CAM ceramics, including zirconia, lithium disilicate (LDS), polymer infiltrated ceramic network (PICN), pre-sintered zirconium-reinforced lithium silicate (PS-ZLS), and PS ZLS with additional sintering (PS-ZLS+AS).</p><p><strong>Materials and methods: </strong>A total of 50 rectangular plate-shaped specimens with A2 shade in 1 mm thickness were investigated (n=10). Each specimen underwent coffee thermocycling for a total of 20 000 cycles and a 20% carbamide peroxide bleaching for 14 days The color changes were calculated using the ΔE00 formula between 3 steps: initially, after thermocycling, and after bleaching steps. A one-way ANOVA, followed by relevant post hoc tests, was used to analyze ΔE00, while a two-way repeated measures ANOVA, followed by Bonferroni-adjusted multiple comparisons for pairwise analyses of lightness, was performed (α = .05).</p><p><strong>Results: </strong>Zirconia and LDS demonstrated the highest stability in color and lightness. In contrast, PS-ZLS and PS-ZLS+AS exhibited significantly greater color changes and lightness reduction during thermocycling, with PS ZLS showing more pronounced alterations than PS-ZLS+AS (P<.001). Bleaching effectively restored the altered color and lost lightness from thermocycling, resulting in less than 1 color change and significantly higher post-bleaching lightness for PICN, PS-ZLS and PS-ZLS+AS.</p><p><strong>Conclusion: </strong>The PS-ZLS groups exhibited the lowest color stability and the greatest lightness reduction during coffee thermocycling. However, additional sintering effectively stabilized the optical properties of PS-ZLS. Bleaching successfully restored the lost lightness and the clinically acceptable original color.</p>","PeriodicalId":94232,"journal":{"name":"The International journal of prosthodontics","volume":"0 0","pages":"1-17"},"PeriodicalIF":0.0000,"publicationDate":"2025-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Effect of Thermocycling and Bleaching on the Color Stability and Lightness of Monolithic CAD-CAM Dental Ceramics.\",\"authors\":\"Mohammadjavad Shirani, Zahra Naghibeiranvand, Maryam Emami, Kamran Azadbakht\",\"doi\":\"10.11607/ijp.9429\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The purpose of this in vitro study was to evaluate the effect of coffee thermocycling and carbamide peroxide bleaching on the color stability and lightness of monolithic CAD-CAM ceramics, including zirconia, lithium disilicate (LDS), polymer infiltrated ceramic network (PICN), pre-sintered zirconium-reinforced lithium silicate (PS-ZLS), and PS ZLS with additional sintering (PS-ZLS+AS).</p><p><strong>Materials and methods: </strong>A total of 50 rectangular plate-shaped specimens with A2 shade in 1 mm thickness were investigated (n=10). Each specimen underwent coffee thermocycling for a total of 20 000 cycles and a 20% carbamide peroxide bleaching for 14 days The color changes were calculated using the ΔE00 formula between 3 steps: initially, after thermocycling, and after bleaching steps. A one-way ANOVA, followed by relevant post hoc tests, was used to analyze ΔE00, while a two-way repeated measures ANOVA, followed by Bonferroni-adjusted multiple comparisons for pairwise analyses of lightness, was performed (α = .05).</p><p><strong>Results: </strong>Zirconia and LDS demonstrated the highest stability in color and lightness. In contrast, PS-ZLS and PS-ZLS+AS exhibited significantly greater color changes and lightness reduction during thermocycling, with PS ZLS showing more pronounced alterations than PS-ZLS+AS (P<.001). Bleaching effectively restored the altered color and lost lightness from thermocycling, resulting in less than 1 color change and significantly higher post-bleaching lightness for PICN, PS-ZLS and PS-ZLS+AS.</p><p><strong>Conclusion: </strong>The PS-ZLS groups exhibited the lowest color stability and the greatest lightness reduction during coffee thermocycling. However, additional sintering effectively stabilized the optical properties of PS-ZLS. Bleaching successfully restored the lost lightness and the clinically acceptable original color.</p>\",\"PeriodicalId\":94232,\"journal\":{\"name\":\"The International journal of prosthodontics\",\"volume\":\"0 0\",\"pages\":\"1-17\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-07-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The International journal of prosthodontics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11607/ijp.9429\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of prosthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/ijp.9429","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:体外研究咖啡热循环和过氧化脲漂白对氧化锆、二硅酸锂(LDS)、聚合物渗透陶瓷网络(PICN)、预烧结锆增强硅酸锂(PS-ZLS)和PS-ZLS外加烧结(PS-ZLS+AS)单片CAD-CAM陶瓷的颜色稳定性和亮度的影响。材料与方法:选取厚度为1 mm的矩形板形标本50例(n=10)。每个样品进行咖啡热循环共20000次,20%过氧化脲漂白14天,使用ΔE00公式计算3个步骤之间的颜色变化:最初,热循环后和漂白步骤后。采用单因素方差分析,然后进行相关的事后检验,对ΔE00进行分析;采用双向重复测量方差分析,然后进行bonferroni校正多重比较,对亮度进行两两分析(α = 0.05)。结果:氧化锆和LDS在颜色和亮度方面表现出最高的稳定性。相比之下,PS-ZLS和PS-ZLS+AS在热循环过程中表现出更大的颜色变化和亮度降低,其中PS-ZLS比PS-ZLS+AS变化更明显(p)。结论:PS-ZLS组在咖啡热循环过程中表现出最低的颜色稳定性和最大的亮度降低。然而,额外烧结有效地稳定了PS-ZLS的光学性能。漂白成功地恢复了失去的亮度和临床可接受的原始颜色。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Effect of Thermocycling and Bleaching on the Color Stability and Lightness of Monolithic CAD-CAM Dental Ceramics.

Purpose: The purpose of this in vitro study was to evaluate the effect of coffee thermocycling and carbamide peroxide bleaching on the color stability and lightness of monolithic CAD-CAM ceramics, including zirconia, lithium disilicate (LDS), polymer infiltrated ceramic network (PICN), pre-sintered zirconium-reinforced lithium silicate (PS-ZLS), and PS ZLS with additional sintering (PS-ZLS+AS).

Materials and methods: A total of 50 rectangular plate-shaped specimens with A2 shade in 1 mm thickness were investigated (n=10). Each specimen underwent coffee thermocycling for a total of 20 000 cycles and a 20% carbamide peroxide bleaching for 14 days The color changes were calculated using the ΔE00 formula between 3 steps: initially, after thermocycling, and after bleaching steps. A one-way ANOVA, followed by relevant post hoc tests, was used to analyze ΔE00, while a two-way repeated measures ANOVA, followed by Bonferroni-adjusted multiple comparisons for pairwise analyses of lightness, was performed (α = .05).

Results: Zirconia and LDS demonstrated the highest stability in color and lightness. In contrast, PS-ZLS and PS-ZLS+AS exhibited significantly greater color changes and lightness reduction during thermocycling, with PS ZLS showing more pronounced alterations than PS-ZLS+AS (P<.001). Bleaching effectively restored the altered color and lost lightness from thermocycling, resulting in less than 1 color change and significantly higher post-bleaching lightness for PICN, PS-ZLS and PS-ZLS+AS.

Conclusion: The PS-ZLS groups exhibited the lowest color stability and the greatest lightness reduction during coffee thermocycling. However, additional sintering effectively stabilized the optical properties of PS-ZLS. Bleaching successfully restored the lost lightness and the clinically acceptable original color.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信