两级热回收与闪蒸工艺在高温热泵制汽系统中的应用与分析

IF 3.5 2区 工程技术 Q1 ENGINEERING, MECHANICAL
Zheng Huang , Yanting Zhang , Lin Wang , Yunlong Zheng , Guanxiang Qiao
{"title":"两级热回收与闪蒸工艺在高温热泵制汽系统中的应用与分析","authors":"Zheng Huang ,&nbsp;Yanting Zhang ,&nbsp;Lin Wang ,&nbsp;Yunlong Zheng ,&nbsp;Guanxiang Qiao","doi":"10.1016/j.ijrefrig.2025.07.001","DOIUrl":null,"url":null,"abstract":"<div><div>In conventional high-temperature heat pump systems for steam production, large temperature and pressure differences between the heat source and heat production cause significant energy losses in compression and expansion process. This research integrates two-stage heat recovery and flash vaporization processes into the two-stage compression heat pump system to enhance its thermodynamic performance. The thermodynamic model of the system was optimized using a simulated annealing algorithm, and experimental validation was conducted. Results indicate that when the evaporation temperature is 50 °C and the condensation temperature ranges from 110 °C to 135 °C, the proposed system’s COP is 3.6–5.2, and its thermodynamic perfection degree is 0.75–0.81, 32.5–62.4 % higher than the conventional cascade system.</div></div>","PeriodicalId":14274,"journal":{"name":"International Journal of Refrigeration-revue Internationale Du Froid","volume":"178 ","pages":"Pages 133-144"},"PeriodicalIF":3.5000,"publicationDate":"2025-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application and analysis of two-stage heat recovery and flash vaporization process in high-temperature heat pump systems for steam production\",\"authors\":\"Zheng Huang ,&nbsp;Yanting Zhang ,&nbsp;Lin Wang ,&nbsp;Yunlong Zheng ,&nbsp;Guanxiang Qiao\",\"doi\":\"10.1016/j.ijrefrig.2025.07.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>In conventional high-temperature heat pump systems for steam production, large temperature and pressure differences between the heat source and heat production cause significant energy losses in compression and expansion process. This research integrates two-stage heat recovery and flash vaporization processes into the two-stage compression heat pump system to enhance its thermodynamic performance. The thermodynamic model of the system was optimized using a simulated annealing algorithm, and experimental validation was conducted. Results indicate that when the evaporation temperature is 50 °C and the condensation temperature ranges from 110 °C to 135 °C, the proposed system’s COP is 3.6–5.2, and its thermodynamic perfection degree is 0.75–0.81, 32.5–62.4 % higher than the conventional cascade system.</div></div>\",\"PeriodicalId\":14274,\"journal\":{\"name\":\"International Journal of Refrigeration-revue Internationale Du Froid\",\"volume\":\"178 \",\"pages\":\"Pages 133-144\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2025-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Refrigeration-revue Internationale Du Froid\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0140700725002695\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Refrigeration-revue Internationale Du Froid","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0140700725002695","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

摘要

在传统的用于蒸汽生产的高温热泵系统中,热源和产热之间的温度和压力差很大,导致压缩和膨胀过程中的能量损失很大。本研究将两级热回收和闪蒸过程整合到两级压缩热泵系统中,以提高其热力学性能。采用模拟退火算法对系统热力学模型进行了优化,并进行了实验验证。结果表明,当蒸发温度为50℃,冷凝温度为110℃~ 135℃时,该系统的COP值为3.6 ~ 5.2,热力完美度为0.75 ~ 0.81,比常规叶栅系统提高32.5 ~ 62.4%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Application and analysis of two-stage heat recovery and flash vaporization process in high-temperature heat pump systems for steam production
In conventional high-temperature heat pump systems for steam production, large temperature and pressure differences between the heat source and heat production cause significant energy losses in compression and expansion process. This research integrates two-stage heat recovery and flash vaporization processes into the two-stage compression heat pump system to enhance its thermodynamic performance. The thermodynamic model of the system was optimized using a simulated annealing algorithm, and experimental validation was conducted. Results indicate that when the evaporation temperature is 50 °C and the condensation temperature ranges from 110 °C to 135 °C, the proposed system’s COP is 3.6–5.2, and its thermodynamic perfection degree is 0.75–0.81, 32.5–62.4 % higher than the conventional cascade system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.30
自引率
12.80%
发文量
363
审稿时长
3.7 months
期刊介绍: The International Journal of Refrigeration is published for the International Institute of Refrigeration (IIR) by Elsevier. It is essential reading for all those wishing to keep abreast of research and industrial news in refrigeration, air conditioning and associated fields. This is particularly important in these times of rapid introduction of alternative refrigerants and the emergence of new technology. The journal has published special issues on alternative refrigerants and novel topics in the field of boiling, condensation, heat pumps, food refrigeration, carbon dioxide, ammonia, hydrocarbons, magnetic refrigeration at room temperature, sorptive cooling, phase change materials and slurries, ejector technology, compressors, and solar cooling. As well as original research papers the International Journal of Refrigeration also includes review articles, papers presented at IIR conferences, short reports and letters describing preliminary results and experimental details, and letters to the Editor on recent areas of discussion and controversy. Other features include forthcoming events, conference reports and book reviews. Papers are published in either English or French with the IIR news section in both languages.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信