光学相干断层扫描青光眼相关参数的年龄相关变化:一项系统综述。

IF 5.1 2区 医学 Q1 OPHTHALMOLOGY
Rodrigo Vilares-Morgado, Kamiel Verbruggen, Ingeborg Stalmans, João Barbosa-Breda
{"title":"光学相干断层扫描青光眼相关参数的年龄相关变化:一项系统综述。","authors":"Rodrigo Vilares-Morgado, Kamiel Verbruggen, Ingeborg Stalmans, João Barbosa-Breda","doi":"10.1016/j.survophthal.2025.06.008","DOIUrl":null,"url":null,"abstract":"<p><p>The specificity of optical coherence tomography (OCT) to detect glaucoma progression can be compromised by the non-adjustment to the healthy aging of OCT glaucoma-related parameters. We summarize the age-related changes of glaucoma-related parameters on OCT in the healthy population. Fifty-one longitudinal studies met our inclusion criteria. Retinal nerve fiber layer (RNFL) thickness change was -0.47 ± 0.27 μm/year for Spectralis® OCT, -0.44 ± 0.17 μm/year for Cirrus® OCT and -0.25 ± 0.21 μm/year for Optovue® OCT. Ganglion cell-inner plexiform layer change was -0.24 ± 0.08 μm/year on Cirrus® OCT. Ganglion cell complex change was -0.40 ± 0.26 μm/year on Optovue® OCT. Bruch membrane opening-minimum rim width change was -1.61 ± 0.14 μm/year on Spectralis® OCT. Vessel density change was -0.33 ± 0.50 %/year on OCTA, measured with Optovue® OCT. Aging in the healthy population leads to a progressive decrease of glaucoma-related parameters. This needs to be considered when assessing glaucoma patients for possible progression measured through OCT or OCT-angiography.</p>","PeriodicalId":22102,"journal":{"name":"Survey of ophthalmology","volume":" ","pages":""},"PeriodicalIF":5.1000,"publicationDate":"2025-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Age-related changes in optical coherence tomography glaucoma-related parameters: A systematic review.\",\"authors\":\"Rodrigo Vilares-Morgado, Kamiel Verbruggen, Ingeborg Stalmans, João Barbosa-Breda\",\"doi\":\"10.1016/j.survophthal.2025.06.008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The specificity of optical coherence tomography (OCT) to detect glaucoma progression can be compromised by the non-adjustment to the healthy aging of OCT glaucoma-related parameters. We summarize the age-related changes of glaucoma-related parameters on OCT in the healthy population. Fifty-one longitudinal studies met our inclusion criteria. Retinal nerve fiber layer (RNFL) thickness change was -0.47 ± 0.27 μm/year for Spectralis® OCT, -0.44 ± 0.17 μm/year for Cirrus® OCT and -0.25 ± 0.21 μm/year for Optovue® OCT. Ganglion cell-inner plexiform layer change was -0.24 ± 0.08 μm/year on Cirrus® OCT. Ganglion cell complex change was -0.40 ± 0.26 μm/year on Optovue® OCT. Bruch membrane opening-minimum rim width change was -1.61 ± 0.14 μm/year on Spectralis® OCT. Vessel density change was -0.33 ± 0.50 %/year on OCTA, measured with Optovue® OCT. Aging in the healthy population leads to a progressive decrease of glaucoma-related parameters. This needs to be considered when assessing glaucoma patients for possible progression measured through OCT or OCT-angiography.</p>\",\"PeriodicalId\":22102,\"journal\":{\"name\":\"Survey of ophthalmology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":5.1000,\"publicationDate\":\"2025-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Survey of ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.survophthal.2025.06.008\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Survey of ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.survophthal.2025.06.008","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

光学相干断层扫描(OCT)检测青光眼进展的特异性可能会因未调整OCT青光眼相关参数的健康老化而受到损害。我们总结了健康人群青光眼相关OCT参数的年龄变化。51项纵向研究符合我们的纳入标准。Spectralis®OCT视网膜神经纤维层(RNFL)厚度变化为-0.47±0.27 μm/年;Cirrus®OCT为-0.44±0.17 μm/年,Optovue®OCT为-0.25±0.21 μm/年。Cirrus®OCT的神经节细胞-内丛状层(GCIPL)变化为-0.24±0.08 μm/年。Optovue®OCT的神经节细胞复合物(GCC)变化为-0.40±0.26 μm/年。健康人群的老龄化导致青光眼相关参数的逐渐下降。在通过OCT或OCT血管造影评估青光眼患者可能的进展时,需要考虑到这一点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Age-related changes in optical coherence tomography glaucoma-related parameters: A systematic review.

The specificity of optical coherence tomography (OCT) to detect glaucoma progression can be compromised by the non-adjustment to the healthy aging of OCT glaucoma-related parameters. We summarize the age-related changes of glaucoma-related parameters on OCT in the healthy population. Fifty-one longitudinal studies met our inclusion criteria. Retinal nerve fiber layer (RNFL) thickness change was -0.47 ± 0.27 μm/year for Spectralis® OCT, -0.44 ± 0.17 μm/year for Cirrus® OCT and -0.25 ± 0.21 μm/year for Optovue® OCT. Ganglion cell-inner plexiform layer change was -0.24 ± 0.08 μm/year on Cirrus® OCT. Ganglion cell complex change was -0.40 ± 0.26 μm/year on Optovue® OCT. Bruch membrane opening-minimum rim width change was -1.61 ± 0.14 μm/year on Spectralis® OCT. Vessel density change was -0.33 ± 0.50 %/year on OCTA, measured with Optovue® OCT. Aging in the healthy population leads to a progressive decrease of glaucoma-related parameters. This needs to be considered when assessing glaucoma patients for possible progression measured through OCT or OCT-angiography.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Survey of ophthalmology
Survey of ophthalmology 医学-眼科学
CiteScore
10.30
自引率
2.00%
发文量
138
审稿时长
14.8 weeks
期刊介绍: Survey of Ophthalmology is a clinically oriented review journal designed to keep ophthalmologists up to date. Comprehensive major review articles, written by experts and stringently refereed, integrate the literature on subjects selected for their clinical importance. Survey also includes feature articles, section reviews, book reviews, and abstracts.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信