在印度西部的一家三级肿瘤医院,储存前白细胞诱导对红细胞浓缩物和新一代白细胞过滤器性能的影响。

IF 1 Q4 MEDICINE, RESEARCH & EXPERIMENTAL
African Journal of Laboratory Medicine Pub Date : 2025-06-25 eCollection Date: 2025-01-01 DOI:10.4102/ajlm.v14i1.2723
Deep Madkaiker, Shashank Ojha, Arunkumar N, Kalpesh Chawan
{"title":"在印度西部的一家三级肿瘤医院,储存前白细胞诱导对红细胞浓缩物和新一代白细胞过滤器性能的影响。","authors":"Deep Madkaiker, Shashank Ojha, Arunkumar N, Kalpesh Chawan","doi":"10.4102/ajlm.v14i1.2723","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Leukoreduction is a post-processing technique that reduces residual leukocytes in cellular blood components. Previous studies have evaluated these parameters mainly among older generation leuko-filters.</p><p><strong>Objective: </strong>This study evaluated the immediate effects of pre-storage leukoreduction on red cell indices and the performance efficacy of two newer generation leuko-filters.</p><p><strong>Methods: </strong>This retrospective analysis collected quality control data before and after leukoreduction for erythrocyte concentrates (ECs) from laboratory registers from the Blood Transfusion Laboratory at the Advanced Centre for Treatment, Research and Education in Cancer in Mumbai, India, for the period January 2015 to December 2019. Data related to red cell indices and performance characteristics for Fresenius and Macopharma filters were included.</p><p><strong>Results: </strong>A total of 500 records was included in the study. All EC units demonstrated a 99.99% leukocyte log reduction, with both filters showing equal efficacy. Post-leukoreduction haemoglobin concentrations were lower than the pre-leukoreduction for all units (<i>p</i> < 0.001). Of those prepared from 350 mL units, 11.6% (28/240) had haemoglobin levels under 40 g/bag as compared to 1.1% (3/260) among those prepared from 450 mL units. All indices exhibited statistically significant changes after leukoreduction (<i>p</i> < 0.001) except for mean corpuscular haemoglobin (<i>p</i> = 0.215). The Fresenius filter required less time for leukoreduction compared to the Macopharma filter (<i>p</i> < 0.001).</p><p><strong>Conclusion: </strong>Red cell indices show several changes following leukoreduction. Further studies are needed to assess the microscopic and functional impact of leukoreduction. Leuko-filters vary in their performance characteristics, which may influence vendor selection.</p><p><strong>What this study adds: </strong>This study found changes among several red cell indices after leukoreduction of ECs, which have not been extensively studied in previous literature. Further, we found that the newer generation leuko-filters differ in specific performance characteristics, which may influence vendor selection.</p>","PeriodicalId":45412,"journal":{"name":"African Journal of Laboratory Medicine","volume":"14 1","pages":"2723"},"PeriodicalIF":1.0000,"publicationDate":"2025-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12223950/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effects of pre-storage leukoreduction on erythrocyte concentrates and performance of newer generation leuko-filters at a tertiary care oncology hospital in Western India.\",\"authors\":\"Deep Madkaiker, Shashank Ojha, Arunkumar N, Kalpesh Chawan\",\"doi\":\"10.4102/ajlm.v14i1.2723\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Leukoreduction is a post-processing technique that reduces residual leukocytes in cellular blood components. Previous studies have evaluated these parameters mainly among older generation leuko-filters.</p><p><strong>Objective: </strong>This study evaluated the immediate effects of pre-storage leukoreduction on red cell indices and the performance efficacy of two newer generation leuko-filters.</p><p><strong>Methods: </strong>This retrospective analysis collected quality control data before and after leukoreduction for erythrocyte concentrates (ECs) from laboratory registers from the Blood Transfusion Laboratory at the Advanced Centre for Treatment, Research and Education in Cancer in Mumbai, India, for the period January 2015 to December 2019. Data related to red cell indices and performance characteristics for Fresenius and Macopharma filters were included.</p><p><strong>Results: </strong>A total of 500 records was included in the study. All EC units demonstrated a 99.99% leukocyte log reduction, with both filters showing equal efficacy. Post-leukoreduction haemoglobin concentrations were lower than the pre-leukoreduction for all units (<i>p</i> < 0.001). Of those prepared from 350 mL units, 11.6% (28/240) had haemoglobin levels under 40 g/bag as compared to 1.1% (3/260) among those prepared from 450 mL units. All indices exhibited statistically significant changes after leukoreduction (<i>p</i> < 0.001) except for mean corpuscular haemoglobin (<i>p</i> = 0.215). The Fresenius filter required less time for leukoreduction compared to the Macopharma filter (<i>p</i> < 0.001).</p><p><strong>Conclusion: </strong>Red cell indices show several changes following leukoreduction. Further studies are needed to assess the microscopic and functional impact of leukoreduction. Leuko-filters vary in their performance characteristics, which may influence vendor selection.</p><p><strong>What this study adds: </strong>This study found changes among several red cell indices after leukoreduction of ECs, which have not been extensively studied in previous literature. Further, we found that the newer generation leuko-filters differ in specific performance characteristics, which may influence vendor selection.</p>\",\"PeriodicalId\":45412,\"journal\":{\"name\":\"African Journal of Laboratory Medicine\",\"volume\":\"14 1\",\"pages\":\"2723\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2025-06-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12223950/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"African Journal of Laboratory Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4102/ajlm.v14i1.2723\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"African Journal of Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4102/ajlm.v14i1.2723","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:白细胞诱导是一种后处理技术,可以减少细胞血液成分中残留的白细胞。以前的研究主要是在较老一代的白细胞过滤器中评估这些参数。目的:评价贮存前白细胞诱导对红细胞指标的直接影响及两种新一代白细胞过滤器的性能效果。方法:本回顾性分析收集了2015年1月至2019年12月期间印度孟买癌症高级治疗、研究和教育中心输血实验室登记的红细胞浓缩物(ECs)白细胞诱导前后的质量控制数据。包括费森尤斯和马药厂滤器的红细胞指标和性能特征。结果:本研究共纳入病历500例。所有EC单元显示白细胞计数减少99.99%,两种过滤器显示相同的效果。所有单位白细胞还原后血红蛋白浓度均低于白细胞还原前(p < 0.001)。在350毫升单位中,11.6%(28/240)的血红蛋白水平低于40克/袋,而在450毫升单位中,这一比例为1.1%(3/260)。除平均红细胞血红蛋白(p = 0.215)外,白细胞减少后所有指标均有统计学意义的变化(p < 0.001)。与Macopharma滤器相比,费森尤斯滤器所需的白细胞诱导时间更短(p < 0.001)。结论:白细胞诱导后红细胞指标发生了一些变化。需要进一步的研究来评估白细胞减少的微观和功能影响。白过滤器的性能特性各不相同,这可能会影响供应商的选择。本研究补充:本研究发现了内皮细胞白细胞诱导后几种红细胞指标的变化,这在以前的文献中没有得到广泛的研究。此外,我们发现新一代的白过滤器在特定的性能特征上有所不同,这可能会影响供应商的选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effects of pre-storage leukoreduction on erythrocyte concentrates and performance of newer generation leuko-filters at a tertiary care oncology hospital in Western India.

Background: Leukoreduction is a post-processing technique that reduces residual leukocytes in cellular blood components. Previous studies have evaluated these parameters mainly among older generation leuko-filters.

Objective: This study evaluated the immediate effects of pre-storage leukoreduction on red cell indices and the performance efficacy of two newer generation leuko-filters.

Methods: This retrospective analysis collected quality control data before and after leukoreduction for erythrocyte concentrates (ECs) from laboratory registers from the Blood Transfusion Laboratory at the Advanced Centre for Treatment, Research and Education in Cancer in Mumbai, India, for the period January 2015 to December 2019. Data related to red cell indices and performance characteristics for Fresenius and Macopharma filters were included.

Results: A total of 500 records was included in the study. All EC units demonstrated a 99.99% leukocyte log reduction, with both filters showing equal efficacy. Post-leukoreduction haemoglobin concentrations were lower than the pre-leukoreduction for all units (p < 0.001). Of those prepared from 350 mL units, 11.6% (28/240) had haemoglobin levels under 40 g/bag as compared to 1.1% (3/260) among those prepared from 450 mL units. All indices exhibited statistically significant changes after leukoreduction (p < 0.001) except for mean corpuscular haemoglobin (p = 0.215). The Fresenius filter required less time for leukoreduction compared to the Macopharma filter (p < 0.001).

Conclusion: Red cell indices show several changes following leukoreduction. Further studies are needed to assess the microscopic and functional impact of leukoreduction. Leuko-filters vary in their performance characteristics, which may influence vendor selection.

What this study adds: This study found changes among several red cell indices after leukoreduction of ECs, which have not been extensively studied in previous literature. Further, we found that the newer generation leuko-filters differ in specific performance characteristics, which may influence vendor selection.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
African Journal of Laboratory Medicine
African Journal of Laboratory Medicine MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
1.70
自引率
9.10%
发文量
53
审稿时长
12 weeks
期刊介绍: The African Journal of Laboratory Medicine, the official journal of ASLM, focuses on the role of the laboratory and its professionals in the clinical and public healthcare sectors,and is specifically based on an African frame of reference. Emphasis is on all aspects that promote and contribute to the laboratory medicine practices of Africa. This includes, amongst others: laboratories, biomedical scientists and clinicians, medical community, public health officials and policy makers, laboratory systems and policies (translation of laboratory knowledge, practices and technologies in clinical care), interfaces of laboratory with medical science, laboratory-based epidemiology, laboratory investigations, evidence-based effectiveness in real world (actual) settings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信