{"title":"基于非接触生命数据构建的昼夜节律模型的异常检测系统初步检测大叶性肺炎急性加重和心力衰竭。","authors":"Tsuyoshi Kobayashi, Kenichi Hashimoto, Takemi Matsui","doi":"10.4235/agmr.25.0059","DOIUrl":null,"url":null,"abstract":"<p><p>Many frail older person patients with multiple comorbidities are hospitalized in long-term care hospitals and nursing facilities. Due to pre-existing conditions and immunosuppressive states, there are significant individual differences, such as weakness, sluggishness, and asymptomatic status. These differences make it challenging to find a patient's exacerbation using a conventional threshold of vital signs. We developed a Circadian Rhythm Anomaly-Detection system designed for each patient, which compares each patient's past 2 weeks average respiratory rate circadian rhythm with that of last 24 hours. Respiratory rate was measured using a piezoelectric sensor located under the mattress. Prior to the doctor's diagnosis of acute exacerbation of lobar pneumonia and heart failure, a bedridden 88-year-old female patient with multiple chronic diseases showed abnormal Circadian Rhythm status. However, there were no significant changes in vital signs. Circadian Rhythm Anomaly-Detection system appears promising for a future system to promote medical inspection to elderlies.</p>","PeriodicalId":44729,"journal":{"name":"Annals of Geriatric Medicine and Research","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2025-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Preliminary Detection of Acute Exacerbation of Lobar Pneumonia and Heart Failure Using an Anomaly-detection System Based on a Circadian Rhythm Model Constructed from Non-contact Vital Data.\",\"authors\":\"Tsuyoshi Kobayashi, Kenichi Hashimoto, Takemi Matsui\",\"doi\":\"10.4235/agmr.25.0059\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Many frail older person patients with multiple comorbidities are hospitalized in long-term care hospitals and nursing facilities. Due to pre-existing conditions and immunosuppressive states, there are significant individual differences, such as weakness, sluggishness, and asymptomatic status. These differences make it challenging to find a patient's exacerbation using a conventional threshold of vital signs. We developed a Circadian Rhythm Anomaly-Detection system designed for each patient, which compares each patient's past 2 weeks average respiratory rate circadian rhythm with that of last 24 hours. Respiratory rate was measured using a piezoelectric sensor located under the mattress. Prior to the doctor's diagnosis of acute exacerbation of lobar pneumonia and heart failure, a bedridden 88-year-old female patient with multiple chronic diseases showed abnormal Circadian Rhythm status. However, there were no significant changes in vital signs. Circadian Rhythm Anomaly-Detection system appears promising for a future system to promote medical inspection to elderlies.</p>\",\"PeriodicalId\":44729,\"journal\":{\"name\":\"Annals of Geriatric Medicine and Research\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2025-07-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Geriatric Medicine and Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4235/agmr.25.0059\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"GERIATRICS & GERONTOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Geriatric Medicine and Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4235/agmr.25.0059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"GERIATRICS & GERONTOLOGY","Score":null,"Total":0}
Preliminary Detection of Acute Exacerbation of Lobar Pneumonia and Heart Failure Using an Anomaly-detection System Based on a Circadian Rhythm Model Constructed from Non-contact Vital Data.
Many frail older person patients with multiple comorbidities are hospitalized in long-term care hospitals and nursing facilities. Due to pre-existing conditions and immunosuppressive states, there are significant individual differences, such as weakness, sluggishness, and asymptomatic status. These differences make it challenging to find a patient's exacerbation using a conventional threshold of vital signs. We developed a Circadian Rhythm Anomaly-Detection system designed for each patient, which compares each patient's past 2 weeks average respiratory rate circadian rhythm with that of last 24 hours. Respiratory rate was measured using a piezoelectric sensor located under the mattress. Prior to the doctor's diagnosis of acute exacerbation of lobar pneumonia and heart failure, a bedridden 88-year-old female patient with multiple chronic diseases showed abnormal Circadian Rhythm status. However, there were no significant changes in vital signs. Circadian Rhythm Anomaly-Detection system appears promising for a future system to promote medical inspection to elderlies.