基于三维几何信息的听骨链自动测量方法探索。

IF 18.1 Q1 ENGINEERING, BIOMEDICAL
Cyborg and bionic systems (Washington, D.C.) Pub Date : 2025-07-02 eCollection Date: 2025-01-01 DOI:10.34133/cbsystems.0305
Mengshi Zhang, Yufan Zhang, Sihui Guo, Xiaoguang Li, Li Zhuo, Yuxue Ren, Wei Chen, Yili Feng, Ruowei Tang, Han Lv, Pengfei Zhao, Zhenchang Wang, Hongxia Yin
{"title":"基于三维几何信息的听骨链自动测量方法探索。","authors":"Mengshi Zhang, Yufan Zhang, Sihui Guo, Xiaoguang Li, Li Zhuo, Yuxue Ren, Wei Chen, Yili Feng, Ruowei Tang, Han Lv, Pengfei Zhao, Zhenchang Wang, Hongxia Yin","doi":"10.34133/cbsystems.0305","DOIUrl":null,"url":null,"abstract":"<p><p>Abnormalities in the ossicular chain, a key middle-ear component that is crucial for sound transmission, can lead to conductive hearing loss; reconstruction offers an effective treatment. Accurate preoperative ossicular-chain measurements are essential for creating prostheses; however, current methods rely on cadaver studies or manual measurements from 2-dimensional images, which are time-intensive and laborious and depend heavily on radiologist expertise. To improve efficiency, we aimed to develop a systematic approach for automated ossicular-chain segmentation and measurement using ultra-high-resolution computed tomography (U-HRCT). One hundred forty patients (226 ears) with normal ear anatomy underwent U-HRCT. Twelve parameters were defined to measure ossicular-chain components. Automated measurements based on automated segmentation of 226 ear images were verified through manual measurements. We analyzed variations by ear side, sex, and age group. Stapes analysis was limited by segmentation accuracy. Complete segmentation of the malleus, incus, and stapes was achieved in 47 ears. Automated measurements of 8 parameters showed no significant differences compared to manual measurements in 47 cases. Significant sex-based differences emerged in all parameters except stapes footplate length, incudostapedial joint angle, and stapes volume (<i>P</i> = 0.205, <i>P</i> = 0.560, and <i>P</i> = 0.170, respectively). Notable side-specific differences were observed in female incus height and male malleus volume (<i>P</i> = 0.017 and <i>P</i> = 0.037, respectively). No statistically significant differences were found in other parameters across different age groups, except for malleus and incus volumes (<i>P</i> = 0.015 and <i>P</i> = 0.031). The proposed algorithm effectively automated ossicular-chain segmentation and measurement, establishing a normative range for ossicular parameters and providing a valuable reference for detecting abnormalities.</p>","PeriodicalId":72764,"journal":{"name":"Cyborg and bionic systems (Washington, D.C.)","volume":"6 ","pages":"0305"},"PeriodicalIF":18.1000,"publicationDate":"2025-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12214297/pdf/","citationCount":"0","resultStr":"{\"title\":\"Exploration of Automated Measurement for Ossicular Chains Based on 3-Dimensional Geometric Information.\",\"authors\":\"Mengshi Zhang, Yufan Zhang, Sihui Guo, Xiaoguang Li, Li Zhuo, Yuxue Ren, Wei Chen, Yili Feng, Ruowei Tang, Han Lv, Pengfei Zhao, Zhenchang Wang, Hongxia Yin\",\"doi\":\"10.34133/cbsystems.0305\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Abnormalities in the ossicular chain, a key middle-ear component that is crucial for sound transmission, can lead to conductive hearing loss; reconstruction offers an effective treatment. Accurate preoperative ossicular-chain measurements are essential for creating prostheses; however, current methods rely on cadaver studies or manual measurements from 2-dimensional images, which are time-intensive and laborious and depend heavily on radiologist expertise. To improve efficiency, we aimed to develop a systematic approach for automated ossicular-chain segmentation and measurement using ultra-high-resolution computed tomography (U-HRCT). One hundred forty patients (226 ears) with normal ear anatomy underwent U-HRCT. Twelve parameters were defined to measure ossicular-chain components. Automated measurements based on automated segmentation of 226 ear images were verified through manual measurements. We analyzed variations by ear side, sex, and age group. Stapes analysis was limited by segmentation accuracy. Complete segmentation of the malleus, incus, and stapes was achieved in 47 ears. Automated measurements of 8 parameters showed no significant differences compared to manual measurements in 47 cases. Significant sex-based differences emerged in all parameters except stapes footplate length, incudostapedial joint angle, and stapes volume (<i>P</i> = 0.205, <i>P</i> = 0.560, and <i>P</i> = 0.170, respectively). Notable side-specific differences were observed in female incus height and male malleus volume (<i>P</i> = 0.017 and <i>P</i> = 0.037, respectively). No statistically significant differences were found in other parameters across different age groups, except for malleus and incus volumes (<i>P</i> = 0.015 and <i>P</i> = 0.031). The proposed algorithm effectively automated ossicular-chain segmentation and measurement, establishing a normative range for ossicular parameters and providing a valuable reference for detecting abnormalities.</p>\",\"PeriodicalId\":72764,\"journal\":{\"name\":\"Cyborg and bionic systems (Washington, D.C.)\",\"volume\":\"6 \",\"pages\":\"0305\"},\"PeriodicalIF\":18.1000,\"publicationDate\":\"2025-07-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12214297/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cyborg and bionic systems (Washington, D.C.)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.34133/cbsystems.0305\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cyborg and bionic systems (Washington, D.C.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34133/cbsystems.0305","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

听骨链是中耳的一个重要组成部分,对声音的传递至关重要,它的异常可导致传导性听力损失;重建提供了有效的治疗方法。准确的术前听骨链测量对于制作假体至关重要;然而,目前的方法依赖于尸体研究或从二维图像中手动测量,这既费时又费力,而且严重依赖于放射科医生的专业知识。为了提高效率,我们的目标是利用超高分辨率计算机断层扫描(U-HRCT)开发一种系统的自动听骨链分割和测量方法。140例(226耳)正常耳部患者行U-HRCT检查。定义了十二个参数来测量听链成分。通过人工测量验证了基于226张耳图像自动分割的自动测量结果。我们分析了耳侧、性别和年龄组的变化。镫骨分析受分割精度的限制。在47耳中实现了锤骨、砧骨和镫骨的完全分割。在47例中,8个参数的自动测量与人工测量相比无显著差异。除镫骨足板长度、包括镫骨关节角和镫骨体积外,其余参数均存在显著的性别差异(P = 0.205、P = 0.560和P = 0.170)。雌性砧骨高度和雄性砧骨体积的侧特异性差异显著(P = 0.017和P = 0.037)。除锤骨和砧骨体积外,其他参数在不同年龄组间差异均无统计学意义(P = 0.015和P = 0.031)。该算法有效地实现了听骨链的自动分割和测量,建立了听骨参数的规范范围,为异常检测提供了有价值的参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Exploration of Automated Measurement for Ossicular Chains Based on 3-Dimensional Geometric Information.

Abnormalities in the ossicular chain, a key middle-ear component that is crucial for sound transmission, can lead to conductive hearing loss; reconstruction offers an effective treatment. Accurate preoperative ossicular-chain measurements are essential for creating prostheses; however, current methods rely on cadaver studies or manual measurements from 2-dimensional images, which are time-intensive and laborious and depend heavily on radiologist expertise. To improve efficiency, we aimed to develop a systematic approach for automated ossicular-chain segmentation and measurement using ultra-high-resolution computed tomography (U-HRCT). One hundred forty patients (226 ears) with normal ear anatomy underwent U-HRCT. Twelve parameters were defined to measure ossicular-chain components. Automated measurements based on automated segmentation of 226 ear images were verified through manual measurements. We analyzed variations by ear side, sex, and age group. Stapes analysis was limited by segmentation accuracy. Complete segmentation of the malleus, incus, and stapes was achieved in 47 ears. Automated measurements of 8 parameters showed no significant differences compared to manual measurements in 47 cases. Significant sex-based differences emerged in all parameters except stapes footplate length, incudostapedial joint angle, and stapes volume (P = 0.205, P = 0.560, and P = 0.170, respectively). Notable side-specific differences were observed in female incus height and male malleus volume (P = 0.017 and P = 0.037, respectively). No statistically significant differences were found in other parameters across different age groups, except for malleus and incus volumes (P = 0.015 and P = 0.031). The proposed algorithm effectively automated ossicular-chain segmentation and measurement, establishing a normative range for ossicular parameters and providing a valuable reference for detecting abnormalities.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.70
自引率
0.00%
发文量
0
审稿时长
21 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信