印尼望加锡市典型建筑与高中建筑能耗模式

IF 0.8 0 ARCHITECTURE
Yuniar Afifa Nur, Gyuyoung Yoon
{"title":"印尼望加锡市典型建筑与高中建筑能耗模式","authors":"Yuniar Afifa Nur,&nbsp;Gyuyoung Yoon","doi":"10.1002/2475-8876.70038","DOIUrl":null,"url":null,"abstract":"<p>As a country that implements sustainable development, Indonesia sets goals for energy efficiency, especially in the building sector. School buildings as representative building stock are the target of this study. The surveys and data collection were done from 28 high schools in Makassar. In the early stage of energy efficiency design, it is important to investigate the actual condition of school buildings as a foundation for further studies in energy consumption and energy efficiency planning. This paper comprehensively analyzes a typical school building, energy consumption patterns, and constant usage. Besides that, the effect of building conditions on school energy consumption is discussed. The findings of this study indicate that typical school buildings are usually in the south direction where site plan adjacent to the buildings around could lead to some challenges in energy efficiency. The energy consumption pattern reveals two categories, Category 1 has high fluctuation for monthly energy consumption and Category 2 has relatively flat consumption. Thus, two categories may have different site conditions. The study also found that the constant energy use, which assumes as a lighting energy consumption, is 5.87–7.78 W/m<sup>2</sup> or 15.22–20.17 kWh/m<sup>2</sup> per year.</p>","PeriodicalId":42793,"journal":{"name":"Japan Architectural Review","volume":"8 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2025-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/2475-8876.70038","citationCount":"0","resultStr":"{\"title\":\"Typical Building and Energy Consumption Pattern of High School Buildings in Makassar, Indonesia\",\"authors\":\"Yuniar Afifa Nur,&nbsp;Gyuyoung Yoon\",\"doi\":\"10.1002/2475-8876.70038\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>As a country that implements sustainable development, Indonesia sets goals for energy efficiency, especially in the building sector. School buildings as representative building stock are the target of this study. The surveys and data collection were done from 28 high schools in Makassar. In the early stage of energy efficiency design, it is important to investigate the actual condition of school buildings as a foundation for further studies in energy consumption and energy efficiency planning. This paper comprehensively analyzes a typical school building, energy consumption patterns, and constant usage. Besides that, the effect of building conditions on school energy consumption is discussed. The findings of this study indicate that typical school buildings are usually in the south direction where site plan adjacent to the buildings around could lead to some challenges in energy efficiency. The energy consumption pattern reveals two categories, Category 1 has high fluctuation for monthly energy consumption and Category 2 has relatively flat consumption. Thus, two categories may have different site conditions. The study also found that the constant energy use, which assumes as a lighting energy consumption, is 5.87–7.78 W/m<sup>2</sup> or 15.22–20.17 kWh/m<sup>2</sup> per year.</p>\",\"PeriodicalId\":42793,\"journal\":{\"name\":\"Japan Architectural Review\",\"volume\":\"8 1\",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2025-07-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/2475-8876.70038\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Japan Architectural Review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/2475-8876.70038\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"0\",\"JCRName\":\"ARCHITECTURE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japan Architectural Review","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/2475-8876.70038","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"ARCHITECTURE","Score":null,"Total":0}
引用次数: 0

摘要

作为一个实施可持续发展的国家,印度尼西亚制定了能源效率目标,特别是在建筑领域。作为代表性建筑存量的学校建筑是本研究的对象。调查和数据收集来自望加锡的28所高中。在节能设计的前期,对学校建筑的实际情况进行调查,是进一步开展能耗和节能规划研究的基础。本文综合分析了某典型学校建筑的能耗模式和恒常使用情况。此外,还讨论了建筑条件对学校能耗的影响。本研究的结果表明,典型的学校建筑通常在南方向,场地规划毗邻周围的建筑可能会导致一些能源效率的挑战。能源消费格局呈现两类,第一类月能源消费波动较大,第二类月能源消费相对平稳。因此,两个类别可能具有不同的现场条件。该研究还发现,以照明能耗为例,每年的恒定能源使用量为5.87-7.78 W/m2或15.22-20.17 kWh/m2。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Typical Building and Energy Consumption Pattern of High School Buildings in Makassar, Indonesia

Typical Building and Energy Consumption Pattern of High School Buildings in Makassar, Indonesia

As a country that implements sustainable development, Indonesia sets goals for energy efficiency, especially in the building sector. School buildings as representative building stock are the target of this study. The surveys and data collection were done from 28 high schools in Makassar. In the early stage of energy efficiency design, it is important to investigate the actual condition of school buildings as a foundation for further studies in energy consumption and energy efficiency planning. This paper comprehensively analyzes a typical school building, energy consumption patterns, and constant usage. Besides that, the effect of building conditions on school energy consumption is discussed. The findings of this study indicate that typical school buildings are usually in the south direction where site plan adjacent to the buildings around could lead to some challenges in energy efficiency. The energy consumption pattern reveals two categories, Category 1 has high fluctuation for monthly energy consumption and Category 2 has relatively flat consumption. Thus, two categories may have different site conditions. The study also found that the constant energy use, which assumes as a lighting energy consumption, is 5.87–7.78 W/m2 or 15.22–20.17 kWh/m2 per year.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.20
自引率
11.10%
发文量
58
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信