成功经皮冠状动脉介入治疗的目标病变与丢失的支架。

IF 0.7 4区 医学 Q3 MEDICINE, GENERAL & INTERNAL
Maro Dragičević, Ivica Premužić Meštrović, Matija Marković, Mario Stipinović, Ena Kurtić, Ivica Paulić, Tomislav Letilović
{"title":"成功经皮冠状动脉介入治疗的目标病变与丢失的支架。","authors":"Maro Dragičević, Ivica Premužić Meštrović, Matija Marković, Mario Stipinović, Ena Kurtić, Ivica Paulić, Tomislav Letilović","doi":"10.20471/acc.2024.63.s1.4","DOIUrl":null,"url":null,"abstract":"<p><p>The loss of a stent during percutaneous coronary intervention (PCI) is a rare complication of the procedure. Multiple manoeuvres for the stent extraction exist, using a small balloon being a common one (2). This case report demonstrates the loss of stent in the proximal segment of the RCA whose extraction attempt with a small size SCB failed. The SCB was unable to cross through the stent and kept pushing the stent distally up until the target location where it successfully crossed through the stent. Subsequent dilatation with larger size balloons achieved full stent expansion at the target location.</p>","PeriodicalId":7072,"journal":{"name":"Acta clinica Croatica","volume":"63 Suppl1","pages":"23-25"},"PeriodicalIF":0.7000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12207854/pdf/","citationCount":"0","resultStr":"{\"title\":\"SUCCESSFUL PERCUTANEOUS CORONARY INTERVENTION OF THE TARGET LESION WITH THE LOST STENT.\",\"authors\":\"Maro Dragičević, Ivica Premužić Meštrović, Matija Marković, Mario Stipinović, Ena Kurtić, Ivica Paulić, Tomislav Letilović\",\"doi\":\"10.20471/acc.2024.63.s1.4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The loss of a stent during percutaneous coronary intervention (PCI) is a rare complication of the procedure. Multiple manoeuvres for the stent extraction exist, using a small balloon being a common one (2). This case report demonstrates the loss of stent in the proximal segment of the RCA whose extraction attempt with a small size SCB failed. The SCB was unable to cross through the stent and kept pushing the stent distally up until the target location where it successfully crossed through the stent. Subsequent dilatation with larger size balloons achieved full stent expansion at the target location.</p>\",\"PeriodicalId\":7072,\"journal\":{\"name\":\"Acta clinica Croatica\",\"volume\":\"63 Suppl1\",\"pages\":\"23-25\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12207854/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta clinica Croatica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.20471/acc.2024.63.s1.4\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta clinica Croatica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.20471/acc.2024.63.s1.4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

经皮冠状动脉介入治疗(PCI)过程中支架丢失是一种罕见的并发症。支架取出有多种方法,常用的方法是使用小球囊。本病例报告展示了RCA近段支架的丢失,其小尺寸SCB的拔出尝试失败。SCB无法穿过支架,一直向上推动支架,直到它成功穿过支架的目标位置。随后使用更大尺寸的球囊进行扩张,使支架在目标位置完全扩张。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
SUCCESSFUL PERCUTANEOUS CORONARY INTERVENTION OF THE TARGET LESION WITH THE LOST STENT.

The loss of a stent during percutaneous coronary intervention (PCI) is a rare complication of the procedure. Multiple manoeuvres for the stent extraction exist, using a small balloon being a common one (2). This case report demonstrates the loss of stent in the proximal segment of the RCA whose extraction attempt with a small size SCB failed. The SCB was unable to cross through the stent and kept pushing the stent distally up until the target location where it successfully crossed through the stent. Subsequent dilatation with larger size balloons achieved full stent expansion at the target location.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta clinica Croatica
Acta clinica Croatica 医学-医学:内科
CiteScore
1.10
自引率
16.70%
发文量
38
审稿时长
6-12 weeks
期刊介绍: Acta Clinica Croatica is a peer reviewed general medical journal that publishes original articles that advance and improve medical science and practice and that serve the purpose of transfer of original and valuable information to journal readers. Acta Clinica Croatica is published in English four times a year.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信