Robert Bernat, Volker Windmüller, Vasileios Leivaditis, Manfred Dahm, Burghard Schumacher
{"title":"瓣膜内植入失败一例报告。","authors":"Robert Bernat, Volker Windmüller, Vasileios Leivaditis, Manfred Dahm, Burghard Schumacher","doi":"10.20471/acc.2024.63.s1.16","DOIUrl":null,"url":null,"abstract":"<p><p>Valve-in-Valve (ViV) procedures for failed surgical bioprostheses are becoming increasingly common. We present a case of a 73-year-old male patient with significant comorbidities who underwent a primary transcatheter aortic valve implantation (TAVI) with an Evolut 29 mm (Medtronic, Minneapolis, MN, USA) valve. This TAVI-prosthesis implantation failed due to the inability to fix the valve at the appropriate height to achieve an optimal hemodynamic result. The valve had to be snared and pulled into an adequate position and was then fixed by an implantation of another TAVI-prosthesis (29 mm Sapien S3, Edwards Lifesciences, Irvine, CA, USA) with optimal final result. The patient was discharged after significant clinical improvement and without further complications.</p>","PeriodicalId":7072,"journal":{"name":"Acta clinica Croatica","volume":"63 Suppl1","pages":"86-89"},"PeriodicalIF":0.7000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12207850/pdf/","citationCount":"0","resultStr":"{\"title\":\"VALVE-IN-VALVE IMPLANTATION GONE SOUTH: A CASE REPORT.\",\"authors\":\"Robert Bernat, Volker Windmüller, Vasileios Leivaditis, Manfred Dahm, Burghard Schumacher\",\"doi\":\"10.20471/acc.2024.63.s1.16\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Valve-in-Valve (ViV) procedures for failed surgical bioprostheses are becoming increasingly common. We present a case of a 73-year-old male patient with significant comorbidities who underwent a primary transcatheter aortic valve implantation (TAVI) with an Evolut 29 mm (Medtronic, Minneapolis, MN, USA) valve. This TAVI-prosthesis implantation failed due to the inability to fix the valve at the appropriate height to achieve an optimal hemodynamic result. The valve had to be snared and pulled into an adequate position and was then fixed by an implantation of another TAVI-prosthesis (29 mm Sapien S3, Edwards Lifesciences, Irvine, CA, USA) with optimal final result. The patient was discharged after significant clinical improvement and without further complications.</p>\",\"PeriodicalId\":7072,\"journal\":{\"name\":\"Acta clinica Croatica\",\"volume\":\"63 Suppl1\",\"pages\":\"86-89\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12207850/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta clinica Croatica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.20471/acc.2024.63.s1.16\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta clinica Croatica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.20471/acc.2024.63.s1.16","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
VALVE-IN-VALVE IMPLANTATION GONE SOUTH: A CASE REPORT.
Valve-in-Valve (ViV) procedures for failed surgical bioprostheses are becoming increasingly common. We present a case of a 73-year-old male patient with significant comorbidities who underwent a primary transcatheter aortic valve implantation (TAVI) with an Evolut 29 mm (Medtronic, Minneapolis, MN, USA) valve. This TAVI-prosthesis implantation failed due to the inability to fix the valve at the appropriate height to achieve an optimal hemodynamic result. The valve had to be snared and pulled into an adequate position and was then fixed by an implantation of another TAVI-prosthesis (29 mm Sapien S3, Edwards Lifesciences, Irvine, CA, USA) with optimal final result. The patient was discharged after significant clinical improvement and without further complications.
期刊介绍:
Acta Clinica Croatica is a peer reviewed general medical journal that publishes original articles that advance and improve medical science and practice and that serve the purpose of transfer of original and valuable information to journal readers. Acta Clinica Croatica is published in English four times a year.