Elias Karam, Fabian Kockelmann, Petru Bucur, Nicolas Michot, Ali Ouaissi, Sarah Barbay, Laila Ouguerri, Valentina Romdhane, Sébastien Roger, Urs Giger-Pabst, Mehdi Ouaissi
{"title":"在猪模型的体内研究中,加强奥沙利铂在加压腹腔内气溶胶化疗中的输送的喷嘴设计的比较评价。","authors":"Elias Karam, Fabian Kockelmann, Petru Bucur, Nicolas Michot, Ali Ouaissi, Sarah Barbay, Laila Ouguerri, Valentina Romdhane, Sébastien Roger, Urs Giger-Pabst, Mehdi Ouaissi","doi":"10.1245/s10434-025-17684-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Various nozzle designs are used in pressurized intraperitoneal aerosol chemotherapy (PIPAC), but comparative in vivo data on their pharmacologic effects are limited.</p><p><strong>Methods: </strong>Three groups of four pigs each received PIPAC with oxaliplatin (92 mg) using nebulizers with different designs: group 1 (full-spray-cone single directional), group 2 (hollow-spray-cone single directional), and group 3 (full-spray-cone multidirectional). Oxaliplatin concentrations (µg/g) were measured in blood, peritoneal tissue, and intra-abdominal fluid using inductively coupled plasma mass spectrometry.</p><p><strong>Results: </strong>No significant differences in mean oxaliplatin concentrations in peritoneal tissue were observed: group 1 (12.37 ± 10.81 µg/g), group 2 (5.83 ± 6.18 µg/g), group 3 (9.46 ± 6.10 µg/g) ( p = 0.1002). However, group 3 had a significantly higher mean total oxaliplatin concentration in visceral peritoneal tissue (3.97 ± 0.63 µg/g) than group 1 (2.6 ± 0.56 µg/g) or group 2 (2.15 ± 0.37 µg/g ( p = 0.028). The mean total tissue uptake was also higher in group 3 (41.98 mg) than in group 1 (28.14 mg) or group 2 (36.65 mg) (p = 0.05). Pairwise comparisons showed no significant differences (group 1 vs group 2 [p = 0.1000], group 2 vs group 3 [p = 0.700]). No significant differences in blood absorption were noted (p = 0.106).</p><p><strong>Conclusion: </strong>The full-spray-cone multidirectional nebulizer design in group 3 resulted in significantly higher oxaliplatin concentrations in the small bowel peritoneum with greater total oxaliplatin tissue uptake than with the two other designs.</p>","PeriodicalId":8229,"journal":{"name":"Annals of Surgical Oncology","volume":" ","pages":"7990-7998"},"PeriodicalIF":3.5000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative Evaluation of Nozzle Designs for Enhanced Oxaliplatin Delivery in Pressurized IntraPeritoneal Aerosol Chemotherapy: An In Vivo Study of a Porcine Model.\",\"authors\":\"Elias Karam, Fabian Kockelmann, Petru Bucur, Nicolas Michot, Ali Ouaissi, Sarah Barbay, Laila Ouguerri, Valentina Romdhane, Sébastien Roger, Urs Giger-Pabst, Mehdi Ouaissi\",\"doi\":\"10.1245/s10434-025-17684-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Various nozzle designs are used in pressurized intraperitoneal aerosol chemotherapy (PIPAC), but comparative in vivo data on their pharmacologic effects are limited.</p><p><strong>Methods: </strong>Three groups of four pigs each received PIPAC with oxaliplatin (92 mg) using nebulizers with different designs: group 1 (full-spray-cone single directional), group 2 (hollow-spray-cone single directional), and group 3 (full-spray-cone multidirectional). Oxaliplatin concentrations (µg/g) were measured in blood, peritoneal tissue, and intra-abdominal fluid using inductively coupled plasma mass spectrometry.</p><p><strong>Results: </strong>No significant differences in mean oxaliplatin concentrations in peritoneal tissue were observed: group 1 (12.37 ± 10.81 µg/g), group 2 (5.83 ± 6.18 µg/g), group 3 (9.46 ± 6.10 µg/g) ( p = 0.1002). However, group 3 had a significantly higher mean total oxaliplatin concentration in visceral peritoneal tissue (3.97 ± 0.63 µg/g) than group 1 (2.6 ± 0.56 µg/g) or group 2 (2.15 ± 0.37 µg/g ( p = 0.028). The mean total tissue uptake was also higher in group 3 (41.98 mg) than in group 1 (28.14 mg) or group 2 (36.65 mg) (p = 0.05). Pairwise comparisons showed no significant differences (group 1 vs group 2 [p = 0.1000], group 2 vs group 3 [p = 0.700]). No significant differences in blood absorption were noted (p = 0.106).</p><p><strong>Conclusion: </strong>The full-spray-cone multidirectional nebulizer design in group 3 resulted in significantly higher oxaliplatin concentrations in the small bowel peritoneum with greater total oxaliplatin tissue uptake than with the two other designs.</p>\",\"PeriodicalId\":8229,\"journal\":{\"name\":\"Annals of Surgical Oncology\",\"volume\":\" \",\"pages\":\"7990-7998\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2025-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Surgical Oncology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1245/s10434-025-17684-0\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/6/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ONCOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Surgical Oncology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1245/s10434-025-17684-0","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/6/30 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
Comparative Evaluation of Nozzle Designs for Enhanced Oxaliplatin Delivery in Pressurized IntraPeritoneal Aerosol Chemotherapy: An In Vivo Study of a Porcine Model.
Background: Various nozzle designs are used in pressurized intraperitoneal aerosol chemotherapy (PIPAC), but comparative in vivo data on their pharmacologic effects are limited.
Methods: Three groups of four pigs each received PIPAC with oxaliplatin (92 mg) using nebulizers with different designs: group 1 (full-spray-cone single directional), group 2 (hollow-spray-cone single directional), and group 3 (full-spray-cone multidirectional). Oxaliplatin concentrations (µg/g) were measured in blood, peritoneal tissue, and intra-abdominal fluid using inductively coupled plasma mass spectrometry.
Results: No significant differences in mean oxaliplatin concentrations in peritoneal tissue were observed: group 1 (12.37 ± 10.81 µg/g), group 2 (5.83 ± 6.18 µg/g), group 3 (9.46 ± 6.10 µg/g) ( p = 0.1002). However, group 3 had a significantly higher mean total oxaliplatin concentration in visceral peritoneal tissue (3.97 ± 0.63 µg/g) than group 1 (2.6 ± 0.56 µg/g) or group 2 (2.15 ± 0.37 µg/g ( p = 0.028). The mean total tissue uptake was also higher in group 3 (41.98 mg) than in group 1 (28.14 mg) or group 2 (36.65 mg) (p = 0.05). Pairwise comparisons showed no significant differences (group 1 vs group 2 [p = 0.1000], group 2 vs group 3 [p = 0.700]). No significant differences in blood absorption were noted (p = 0.106).
Conclusion: The full-spray-cone multidirectional nebulizer design in group 3 resulted in significantly higher oxaliplatin concentrations in the small bowel peritoneum with greater total oxaliplatin tissue uptake than with the two other designs.
期刊介绍:
The Annals of Surgical Oncology is the official journal of The Society of Surgical Oncology and is published for the Society by Springer. The Annals publishes original and educational manuscripts about oncology for surgeons from all specialities in academic and community settings.