磁共振成像用于快速、无创、准确评估活鳢卵巢成熟(Cantor, 1842)

IF 3.9 1区 农林科学 Q1 FISHERIES
Wenqian Sun , Weiyin Vivian Liu , Xingyu Chen , Guangcan Lin , Hao Li , Yanting Song , Chengdong Peng , Wen Xiong , Yu Peng , Shangong Wu , Shouqi Xie , Sovan Lek , Mette Sørensen , Haokun Liu , Dong Liu , Lei Pan
{"title":"磁共振成像用于快速、无创、准确评估活鳢卵巢成熟(Cantor, 1842)","authors":"Wenqian Sun ,&nbsp;Weiyin Vivian Liu ,&nbsp;Xingyu Chen ,&nbsp;Guangcan Lin ,&nbsp;Hao Li ,&nbsp;Yanting Song ,&nbsp;Chengdong Peng ,&nbsp;Wen Xiong ,&nbsp;Yu Peng ,&nbsp;Shangong Wu ,&nbsp;Shouqi Xie ,&nbsp;Sovan Lek ,&nbsp;Mette Sørensen ,&nbsp;Haokun Liu ,&nbsp;Dong Liu ,&nbsp;Lei Pan","doi":"10.1016/j.aquaculture.2025.742872","DOIUrl":null,"url":null,"abstract":"<div><div>Current methods for the determination of ovarian maturation in fish have shortcomings. They are often time-consuming, inaccurate, and fish are sacrificed during the procedure. A novel noninvasive and accurate method to assess ovarian maturation can be to use magnetic resonance imaging (MRI). Long scanning time is a limitation for use in fish. A clinical MRI with a new sequence employing a shorter scanning time may be more feasible for the assessment of ovarian maturation in female fish. The aim of this study was to investigate ovarian maturation in <em>Channa argus</em> by clinical MRI with the three-dimensional fast spin echo Cube-flex (3D-FSE-Cube-Flex) T<sub>2</sub>WI sequence, compared with two traditional sequences. The results demonstrated that compared with two traditional sequences, the 3D-FSE-Cube-Flex T<sub>2</sub>WI sequence greatly reduced scanning time (only requiring 140 s per fish) without reducing the scanning quality. A significant correlation (R<sup>2</sup> = 0.985, <em>p</em> &lt; 0.001, <em>N</em> = 112) was found between the percentage volume of the ovary measured by MRI and the gonadosomatic index (GSI). Besides, ovarian maturation MRI images at different development stages were captured. These findings suggest that clinical MRI with the 3D-FSE-Cube-Flex T<sub>2</sub>WI sequence is a rapid, accurate, and noninvasive method for assessing ovarian maturation, with great potential applications in sustainable aquaculture.</div></div>","PeriodicalId":8375,"journal":{"name":"Aquaculture","volume":"610 ","pages":"Article 742872"},"PeriodicalIF":3.9000,"publicationDate":"2025-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Magnetic resonance imaging for rapid, noninvasive and accurate assessment of ovarian maturation in live Channa argus (Cantor, 1842)\",\"authors\":\"Wenqian Sun ,&nbsp;Weiyin Vivian Liu ,&nbsp;Xingyu Chen ,&nbsp;Guangcan Lin ,&nbsp;Hao Li ,&nbsp;Yanting Song ,&nbsp;Chengdong Peng ,&nbsp;Wen Xiong ,&nbsp;Yu Peng ,&nbsp;Shangong Wu ,&nbsp;Shouqi Xie ,&nbsp;Sovan Lek ,&nbsp;Mette Sørensen ,&nbsp;Haokun Liu ,&nbsp;Dong Liu ,&nbsp;Lei Pan\",\"doi\":\"10.1016/j.aquaculture.2025.742872\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Current methods for the determination of ovarian maturation in fish have shortcomings. They are often time-consuming, inaccurate, and fish are sacrificed during the procedure. A novel noninvasive and accurate method to assess ovarian maturation can be to use magnetic resonance imaging (MRI). Long scanning time is a limitation for use in fish. A clinical MRI with a new sequence employing a shorter scanning time may be more feasible for the assessment of ovarian maturation in female fish. The aim of this study was to investigate ovarian maturation in <em>Channa argus</em> by clinical MRI with the three-dimensional fast spin echo Cube-flex (3D-FSE-Cube-Flex) T<sub>2</sub>WI sequence, compared with two traditional sequences. The results demonstrated that compared with two traditional sequences, the 3D-FSE-Cube-Flex T<sub>2</sub>WI sequence greatly reduced scanning time (only requiring 140 s per fish) without reducing the scanning quality. A significant correlation (R<sup>2</sup> = 0.985, <em>p</em> &lt; 0.001, <em>N</em> = 112) was found between the percentage volume of the ovary measured by MRI and the gonadosomatic index (GSI). Besides, ovarian maturation MRI images at different development stages were captured. These findings suggest that clinical MRI with the 3D-FSE-Cube-Flex T<sub>2</sub>WI sequence is a rapid, accurate, and noninvasive method for assessing ovarian maturation, with great potential applications in sustainable aquaculture.</div></div>\",\"PeriodicalId\":8375,\"journal\":{\"name\":\"Aquaculture\",\"volume\":\"610 \",\"pages\":\"Article 742872\"},\"PeriodicalIF\":3.9000,\"publicationDate\":\"2025-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Aquaculture\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0044848625007586\",\"RegionNum\":1,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"FISHERIES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Aquaculture","FirstCategoryId":"97","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0044848625007586","RegionNum":1,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"FISHERIES","Score":null,"Total":0}
引用次数: 0

摘要

目前测定鱼类卵巢成熟的方法存在不足。它们通常是耗时的,不准确的,并且在过程中会牺牲鱼。磁共振成像(MRI)是一种新的、无创的、准确的评估卵巢成熟的方法。扫描时间长是在鱼类中使用的一个限制。临床MRI采用新的序列,采用较短的扫描时间,可能更可行的评估卵巢成熟雌鱼。本研究的目的是通过三维快速自旋回声立方体-flex (3D-FSE-Cube-Flex) T2WI序列的临床MRI与两种传统序列的比较,研究鳢卵巢成熟情况。结果表明,与两种传统序列相比,3D-FSE-Cube-Flex T2WI序列在不降低扫描质量的前提下,大大缩短了扫描时间(每条鱼只需要140 s)。相关性显著(R2 = 0.985, p <;MRI测量的卵巢体积百分比与促性腺指数(GSI)之间的差异为0.001,N = 112)。同时采集不同发育阶段的卵巢成熟MRI图像。这些结果表明,临床MRI 3D-FSE-Cube-Flex T2WI序列是一种快速、准确、无创的评估卵巢成熟的方法,在可持续水产养殖中具有很大的应用潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Magnetic resonance imaging for rapid, noninvasive and accurate assessment of ovarian maturation in live Channa argus (Cantor, 1842)
Current methods for the determination of ovarian maturation in fish have shortcomings. They are often time-consuming, inaccurate, and fish are sacrificed during the procedure. A novel noninvasive and accurate method to assess ovarian maturation can be to use magnetic resonance imaging (MRI). Long scanning time is a limitation for use in fish. A clinical MRI with a new sequence employing a shorter scanning time may be more feasible for the assessment of ovarian maturation in female fish. The aim of this study was to investigate ovarian maturation in Channa argus by clinical MRI with the three-dimensional fast spin echo Cube-flex (3D-FSE-Cube-Flex) T2WI sequence, compared with two traditional sequences. The results demonstrated that compared with two traditional sequences, the 3D-FSE-Cube-Flex T2WI sequence greatly reduced scanning time (only requiring 140 s per fish) without reducing the scanning quality. A significant correlation (R2 = 0.985, p < 0.001, N = 112) was found between the percentage volume of the ovary measured by MRI and the gonadosomatic index (GSI). Besides, ovarian maturation MRI images at different development stages were captured. These findings suggest that clinical MRI with the 3D-FSE-Cube-Flex T2WI sequence is a rapid, accurate, and noninvasive method for assessing ovarian maturation, with great potential applications in sustainable aquaculture.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Aquaculture
Aquaculture 农林科学-海洋与淡水生物学
CiteScore
8.60
自引率
17.80%
发文量
1246
审稿时长
56 days
期刊介绍: Aquaculture is an international journal for the exploration, improvement and management of all freshwater and marine food resources. It publishes novel and innovative research of world-wide interest on farming of aquatic organisms, which includes finfish, mollusks, crustaceans and aquatic plants for human consumption. Research on ornamentals is not a focus of the Journal. Aquaculture only publishes papers with a clear relevance to improving aquaculture practices or a potential application.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信