{"title":"一种基于并联板可变电容的风压传感器:封闭解和数值设计与标定。","authors":"Xiao-Ting He, Jun-Song Ran, Jing-Miao Yin, Jun-Yi Sun, Ying Guo","doi":"10.3390/s25123760","DOIUrl":null,"url":null,"abstract":"<p><p>In this paper, a parallel plate variable capacitor-based wind pressure sensor is proposed, which uses a wind-driven peripherally fixed circular membrane as its pressure-sensitive element and a spring-reset parallel plate variable capacitor as its sensing element. The circular membrane is first driven by the wind, and then it pushes the spring-reset movable electrode plate of the parallel plate variable capacitor to move, resulting in a change in the capacitance of the capacitor. The wind pressure, i.e., the direct action force per unit area exerted by the wind on the circular membrane, is thus detected by measuring the capacitance change of the capacitor. The elastic contact problem between the circular membrane and the spring-reset movable electrode plate is analytically solved, and its closed-form solution is presented, where the usually adopted small rotation angle assumption of the membrane is given up. The analytical relationship between the input pressure and output capacitance of the capacitive wind pressure sensor proposed here is derived. The validity of the closed-form solution is proved, and how to use the closed-form solution and input/output analytical relationship for the numerical design and calibration of the capacitive wind pressure sensor proposed here is illustrated. Finally, the qualitative and quantitative effects of changing design parameters on the capacitance-pressure analytical relationship of the wind pressure measurement system are investigated comprehensively.</p>","PeriodicalId":21698,"journal":{"name":"Sensors","volume":"25 12","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2025-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Parallel Plate Variable Capacitor-Based Wind Pressure Sensor: Closed-Form Solution and Numerical Design and Calibration.\",\"authors\":\"Xiao-Ting He, Jun-Song Ran, Jing-Miao Yin, Jun-Yi Sun, Ying Guo\",\"doi\":\"10.3390/s25123760\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In this paper, a parallel plate variable capacitor-based wind pressure sensor is proposed, which uses a wind-driven peripherally fixed circular membrane as its pressure-sensitive element and a spring-reset parallel plate variable capacitor as its sensing element. The circular membrane is first driven by the wind, and then it pushes the spring-reset movable electrode plate of the parallel plate variable capacitor to move, resulting in a change in the capacitance of the capacitor. The wind pressure, i.e., the direct action force per unit area exerted by the wind on the circular membrane, is thus detected by measuring the capacitance change of the capacitor. The elastic contact problem between the circular membrane and the spring-reset movable electrode plate is analytically solved, and its closed-form solution is presented, where the usually adopted small rotation angle assumption of the membrane is given up. The analytical relationship between the input pressure and output capacitance of the capacitive wind pressure sensor proposed here is derived. The validity of the closed-form solution is proved, and how to use the closed-form solution and input/output analytical relationship for the numerical design and calibration of the capacitive wind pressure sensor proposed here is illustrated. Finally, the qualitative and quantitative effects of changing design parameters on the capacitance-pressure analytical relationship of the wind pressure measurement system are investigated comprehensively.</p>\",\"PeriodicalId\":21698,\"journal\":{\"name\":\"Sensors\",\"volume\":\"25 12\",\"pages\":\"\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2025-06-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://doi.org/10.3390/s25123760\",\"RegionNum\":3,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.3390/s25123760","RegionNum":3,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
A Parallel Plate Variable Capacitor-Based Wind Pressure Sensor: Closed-Form Solution and Numerical Design and Calibration.
In this paper, a parallel plate variable capacitor-based wind pressure sensor is proposed, which uses a wind-driven peripherally fixed circular membrane as its pressure-sensitive element and a spring-reset parallel plate variable capacitor as its sensing element. The circular membrane is first driven by the wind, and then it pushes the spring-reset movable electrode plate of the parallel plate variable capacitor to move, resulting in a change in the capacitance of the capacitor. The wind pressure, i.e., the direct action force per unit area exerted by the wind on the circular membrane, is thus detected by measuring the capacitance change of the capacitor. The elastic contact problem between the circular membrane and the spring-reset movable electrode plate is analytically solved, and its closed-form solution is presented, where the usually adopted small rotation angle assumption of the membrane is given up. The analytical relationship between the input pressure and output capacitance of the capacitive wind pressure sensor proposed here is derived. The validity of the closed-form solution is proved, and how to use the closed-form solution and input/output analytical relationship for the numerical design and calibration of the capacitive wind pressure sensor proposed here is illustrated. Finally, the qualitative and quantitative effects of changing design parameters on the capacitance-pressure analytical relationship of the wind pressure measurement system are investigated comprehensively.
期刊介绍:
Sensors (ISSN 1424-8220) provides an advanced forum for the science and technology of sensors and biosensors. It publishes reviews (including comprehensive reviews on the complete sensors products), regular research papers and short notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.