{"title":"可穿戴式光容积脉搏波连续无创血压监测:非心脏手术后高危患者康复的方法比较研究。","authors":"Moritz Flick, Leon Gebhardt, Alina Bergholz, Kristen K Thomsen, Max Bossemeyer, Alexander Hapfelmeier, Julia Auinger, Bernd Saugel","doi":"10.1097/EJA.0000000000002222","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The Biobeat wrist monitor (BB-613W; Biobeat Technologies, Petah-Tikva, Israel) and the Biobeat chest monitor (BB-613P; Biobeat Technologies) are wearable solutions for continuous noninvasive blood pressure monitoring.</p><p><strong>Objectives: </strong>We aimed to investigate the blood pressure measurement performance of the Biobeat wrist monitor and chest monitor after external calibration.</p><p><strong>Design: </strong>A prospective method comparison study.</p><p><strong>Setting: </strong>University Medical Center Hamburg-Eppendorf, Hamburg, Germany.</p><p><strong>Patients: </strong>Fifty high-risk patients recovering from noncardiac surgery in an advanced postanaesthesia care unit.</p><p><strong>Main outcome measures: </strong>We compared blood pressure measurements from the Biobeat wrist monitor (BPWRIST-ART) and the Biobeat chest monitor (BPCHEST-ART) with intra-arterial blood pressure measurements (BPART). In addition, we aimed to compare blood pressure measurements from the Biobeat wrist monitor (BPWRIST-OSCI) with those from an oscillometric upper-arm cuff (BPOSCI). We used Bland-Altman analysis, four-quadrant plot and error grid analysis for statistical analysis.</p><p><strong>Results: </strong>The mean of the differences ± standard deviation (95%-limits of agreement) between BPWRIST-ART and BPART was 3 ± 11 mmHg (-19 to 25 mmHg) for mean blood pressure with a concordance rate to track 15-min blood pressure changes of 51%. The mean of the differences between BPCHEST-ART and BPART was 3 ± 11 mmHg (-17 to 24 mmHg) for mean blood pressure with a concordance rate to track 15-min blood pressure changes of 61%. The mean of the differences between BPWRIST-OSCI and BPOSCI was 6 ± 11 mmHg (-16 to 27 mmHg) for mean blood pressure with a concordance rate to track 15-min blood pressure changes of 49%.</p><p><strong>Conclusions: </strong>Blood pressure measurements from the Biobeat wrist monitor and the Biobeat chest monitor did not show clinically acceptable agreement either with intra-arterial blood pressure measurements or with blood pressure measurements from an oscillometric upper-arm cuff in high-risk patients recovering from noncardiac surgery in an advanced postanaesthesia care unit.</p>","PeriodicalId":11920,"journal":{"name":"European Journal of Anaesthesiology","volume":" ","pages":""},"PeriodicalIF":4.2000,"publicationDate":"2025-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Continuous noninvasive blood pressure monitoring with wearable photoplethysmography: A method comparison study in high-risk patients recovering from noncardiac surgery.\",\"authors\":\"Moritz Flick, Leon Gebhardt, Alina Bergholz, Kristen K Thomsen, Max Bossemeyer, Alexander Hapfelmeier, Julia Auinger, Bernd Saugel\",\"doi\":\"10.1097/EJA.0000000000002222\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The Biobeat wrist monitor (BB-613W; Biobeat Technologies, Petah-Tikva, Israel) and the Biobeat chest monitor (BB-613P; Biobeat Technologies) are wearable solutions for continuous noninvasive blood pressure monitoring.</p><p><strong>Objectives: </strong>We aimed to investigate the blood pressure measurement performance of the Biobeat wrist monitor and chest monitor after external calibration.</p><p><strong>Design: </strong>A prospective method comparison study.</p><p><strong>Setting: </strong>University Medical Center Hamburg-Eppendorf, Hamburg, Germany.</p><p><strong>Patients: </strong>Fifty high-risk patients recovering from noncardiac surgery in an advanced postanaesthesia care unit.</p><p><strong>Main outcome measures: </strong>We compared blood pressure measurements from the Biobeat wrist monitor (BPWRIST-ART) and the Biobeat chest monitor (BPCHEST-ART) with intra-arterial blood pressure measurements (BPART). In addition, we aimed to compare blood pressure measurements from the Biobeat wrist monitor (BPWRIST-OSCI) with those from an oscillometric upper-arm cuff (BPOSCI). We used Bland-Altman analysis, four-quadrant plot and error grid analysis for statistical analysis.</p><p><strong>Results: </strong>The mean of the differences ± standard deviation (95%-limits of agreement) between BPWRIST-ART and BPART was 3 ± 11 mmHg (-19 to 25 mmHg) for mean blood pressure with a concordance rate to track 15-min blood pressure changes of 51%. The mean of the differences between BPCHEST-ART and BPART was 3 ± 11 mmHg (-17 to 24 mmHg) for mean blood pressure with a concordance rate to track 15-min blood pressure changes of 61%. The mean of the differences between BPWRIST-OSCI and BPOSCI was 6 ± 11 mmHg (-16 to 27 mmHg) for mean blood pressure with a concordance rate to track 15-min blood pressure changes of 49%.</p><p><strong>Conclusions: </strong>Blood pressure measurements from the Biobeat wrist monitor and the Biobeat chest monitor did not show clinically acceptable agreement either with intra-arterial blood pressure measurements or with blood pressure measurements from an oscillometric upper-arm cuff in high-risk patients recovering from noncardiac surgery in an advanced postanaesthesia care unit.</p>\",\"PeriodicalId\":11920,\"journal\":{\"name\":\"European Journal of Anaesthesiology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":4.2000,\"publicationDate\":\"2025-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Anaesthesiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/EJA.0000000000002222\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Anaesthesiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/EJA.0000000000002222","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:Biobeat手腕监测器(BB-613W;Biobeat Technologies, Petah-Tikva, Israel)和Biobeat胸部监护仪(BB-613P;Biobeat Technologies)是一种可穿戴的无创连续血压监测解决方案。目的:研究生物搏击腕带监护仪和胸带监护仪外标后的血压测量性能。设计:前瞻性方法比较研究。地点:德国汉堡埃彭多夫大学医学中心。患者:50例高危非心脏手术患者在高级麻醉后护理病房康复。主要结果测量:我们比较了Biobeat手腕监测仪(bprist -art)和Biobeat胸部监测仪(BPCHEST-ART)的血压测量值与动脉内血压测量值(BPART)。此外,我们的目的是比较Biobeat手腕监测仪(BPWRIST-OSCI)和上臂袖带(BPOSCI)的血压测量值。采用Bland-Altman分析、四象限图和误差网格分析进行统计分析。结果:BPWRIST-ART与BPART的平均血压差异±标准偏差(95%一致限)为3±11 mmHg (19 ~ 25 mmHg),追踪15分钟血压变化的一致性率为51%。bp胸- art与BPART的平均血压差异为3±11 mmHg (-17 ~ 24 mmHg),追踪15分钟血压变化的符合率为61%。BPWRIST-OSCI和BPOSCI的平均血压差异为6±11 mmHg (-16 ~ 27 mmHg),追踪15分钟血压变化的一致性率为49%。结论:在高级麻醉后护理病房中,在非心脏手术后恢复的高危患者中,Biobeat手腕监测仪和Biobeat胸部监测仪测量的血压与动脉内血压或上臂袖带测量的血压没有显示出临床可接受的一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Continuous noninvasive blood pressure monitoring with wearable photoplethysmography: A method comparison study in high-risk patients recovering from noncardiac surgery.

Background: The Biobeat wrist monitor (BB-613W; Biobeat Technologies, Petah-Tikva, Israel) and the Biobeat chest monitor (BB-613P; Biobeat Technologies) are wearable solutions for continuous noninvasive blood pressure monitoring.

Objectives: We aimed to investigate the blood pressure measurement performance of the Biobeat wrist monitor and chest monitor after external calibration.

Design: A prospective method comparison study.

Setting: University Medical Center Hamburg-Eppendorf, Hamburg, Germany.

Patients: Fifty high-risk patients recovering from noncardiac surgery in an advanced postanaesthesia care unit.

Main outcome measures: We compared blood pressure measurements from the Biobeat wrist monitor (BPWRIST-ART) and the Biobeat chest monitor (BPCHEST-ART) with intra-arterial blood pressure measurements (BPART). In addition, we aimed to compare blood pressure measurements from the Biobeat wrist monitor (BPWRIST-OSCI) with those from an oscillometric upper-arm cuff (BPOSCI). We used Bland-Altman analysis, four-quadrant plot and error grid analysis for statistical analysis.

Results: The mean of the differences ± standard deviation (95%-limits of agreement) between BPWRIST-ART and BPART was 3 ± 11 mmHg (-19 to 25 mmHg) for mean blood pressure with a concordance rate to track 15-min blood pressure changes of 51%. The mean of the differences between BPCHEST-ART and BPART was 3 ± 11 mmHg (-17 to 24 mmHg) for mean blood pressure with a concordance rate to track 15-min blood pressure changes of 61%. The mean of the differences between BPWRIST-OSCI and BPOSCI was 6 ± 11 mmHg (-16 to 27 mmHg) for mean blood pressure with a concordance rate to track 15-min blood pressure changes of 49%.

Conclusions: Blood pressure measurements from the Biobeat wrist monitor and the Biobeat chest monitor did not show clinically acceptable agreement either with intra-arterial blood pressure measurements or with blood pressure measurements from an oscillometric upper-arm cuff in high-risk patients recovering from noncardiac surgery in an advanced postanaesthesia care unit.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.90
自引率
11.10%
发文量
351
审稿时长
6-12 weeks
期刊介绍: The European Journal of Anaesthesiology (EJA) publishes original work of high scientific quality in the field of anaesthesiology, pain, emergency medicine and intensive care. Preference is given to experimental work or clinical observation in man, and to laboratory work of clinical relevance. The journal also publishes commissioned reviews by an authority, editorials, invited commentaries, special articles, pro and con debates, and short reports (correspondences, case reports, short reports of clinical studies).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信