超声波换能器、电缆和连接器损坏。预防、检测和管理的图片指南。

IF 1.4 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Journal of Ultrasound Pub Date : 2025-09-01 Epub Date: 2025-06-26 DOI:10.1007/s40477-025-01041-8
Orlando Catalano, Gianluca Gagliardi, Antonio Corvino, Luigi Basile, Carlo Varelli
{"title":"超声波换能器、电缆和连接器损坏。预防、检测和管理的图片指南。","authors":"Orlando Catalano, Gianluca Gagliardi, Antonio Corvino, Luigi Basile, Carlo Varelli","doi":"10.1007/s40477-025-01041-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>All ultrasound scanner components, including transducer arrays, cables, and connectors, may undergo a number of damages, due to injuries, overuse, and aging. Damages impact on image quality, patient safety and healthcare budgets. Probes, particularly represent very important, sophisticated, and expensive components. This review aims to illustrate common forms of damage and educate ultrasound operators on how to recognize, manage, and prevent them.</p><p><strong>Methods: </strong>Through the years we have collected a number of images related to damages to ultrasound equipment, including their appearance on the ultrasound screen, such artifact in B-mode image, color artifact, and noise in image. Based on our experience and a literature review, we provide information and recommendations for recognizing and managing such damage.</p><p><strong>Results: </strong>Common causes of probe damage include improper handling, transport, cleaning, storage, and reprocessing. Main damages are defective cable conditions, acoustic lens issues, crystal damage, transducer house assembly cracks, multiplexer scanning image issue, strain relief condition, connector issues, gel issue/matching layer swelling, and leakage of probe oil.</p><p><strong>Conclusion: </strong>Ultrasound operators must be aware of probe damage and respond promptly to signs of malfunction. This vigilance may prevent irreversible harm and enable repair rather than replacement. Proactive care and regular inspections are essential. Periodic inspection and quality control tests must be scheduled. Remote control of the scanners by the manufacturer may also be helpful.</p>","PeriodicalId":51528,"journal":{"name":"Journal of Ultrasound","volume":" ","pages":"543-549"},"PeriodicalIF":1.4000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12496363/pdf/","citationCount":"0","resultStr":"{\"title\":\"Damage to ultrasound transducers, cables, and connectors. A pictorial guide to prevention, detection, and management.\",\"authors\":\"Orlando Catalano, Gianluca Gagliardi, Antonio Corvino, Luigi Basile, Carlo Varelli\",\"doi\":\"10.1007/s40477-025-01041-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>All ultrasound scanner components, including transducer arrays, cables, and connectors, may undergo a number of damages, due to injuries, overuse, and aging. Damages impact on image quality, patient safety and healthcare budgets. Probes, particularly represent very important, sophisticated, and expensive components. This review aims to illustrate common forms of damage and educate ultrasound operators on how to recognize, manage, and prevent them.</p><p><strong>Methods: </strong>Through the years we have collected a number of images related to damages to ultrasound equipment, including their appearance on the ultrasound screen, such artifact in B-mode image, color artifact, and noise in image. Based on our experience and a literature review, we provide information and recommendations for recognizing and managing such damage.</p><p><strong>Results: </strong>Common causes of probe damage include improper handling, transport, cleaning, storage, and reprocessing. Main damages are defective cable conditions, acoustic lens issues, crystal damage, transducer house assembly cracks, multiplexer scanning image issue, strain relief condition, connector issues, gel issue/matching layer swelling, and leakage of probe oil.</p><p><strong>Conclusion: </strong>Ultrasound operators must be aware of probe damage and respond promptly to signs of malfunction. This vigilance may prevent irreversible harm and enable repair rather than replacement. Proactive care and regular inspections are essential. Periodic inspection and quality control tests must be scheduled. Remote control of the scanners by the manufacturer may also be helpful.</p>\",\"PeriodicalId\":51528,\"journal\":{\"name\":\"Journal of Ultrasound\",\"volume\":\" \",\"pages\":\"543-549\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12496363/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ultrasound\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s40477-025-01041-8\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/6/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s40477-025-01041-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/6/26 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

用途:所有超声扫描仪组件,包括传感器阵列、电缆和连接器,可能会由于损伤、过度使用和老化而遭受许多损坏。损害对图像质量、患者安全和医疗保健预算的影响。探针特别代表非常重要、复杂和昂贵的组件。这篇综述旨在说明常见的损伤形式,并教育超声操作员如何识别、管理和预防它们。方法:多年来,我们收集了大量与超声设备损伤相关的图像,包括超声屏幕上的外观、b模图像中的伪影、彩色伪影和图像中的噪声。根据我们的经验和文献综述,我们提供了识别和管理此类损害的信息和建议。结果:探针损坏的常见原因包括处理、运输、清洁、储存和再加工不当。主要损坏有电缆缺陷、声学透镜问题、晶体损坏、换能器组件裂纹、多路复用器扫描图像问题、应变缓解问题、连接器问题、凝胶问题/匹配层膨胀以及探头油泄漏。结论:超声操作人员必须意识到探头损坏,并及时响应故障迹象。这种警惕可以防止不可逆转的伤害,并使之能够修复而不是替换。主动护理和定期检查至关重要。必须安排定期检验和质量控制试验。制造商对扫描仪的远程控制也可能有所帮助。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Damage to ultrasound transducers, cables, and connectors. A pictorial guide to prevention, detection, and management.

Purpose: All ultrasound scanner components, including transducer arrays, cables, and connectors, may undergo a number of damages, due to injuries, overuse, and aging. Damages impact on image quality, patient safety and healthcare budgets. Probes, particularly represent very important, sophisticated, and expensive components. This review aims to illustrate common forms of damage and educate ultrasound operators on how to recognize, manage, and prevent them.

Methods: Through the years we have collected a number of images related to damages to ultrasound equipment, including their appearance on the ultrasound screen, such artifact in B-mode image, color artifact, and noise in image. Based on our experience and a literature review, we provide information and recommendations for recognizing and managing such damage.

Results: Common causes of probe damage include improper handling, transport, cleaning, storage, and reprocessing. Main damages are defective cable conditions, acoustic lens issues, crystal damage, transducer house assembly cracks, multiplexer scanning image issue, strain relief condition, connector issues, gel issue/matching layer swelling, and leakage of probe oil.

Conclusion: Ultrasound operators must be aware of probe damage and respond promptly to signs of malfunction. This vigilance may prevent irreversible harm and enable repair rather than replacement. Proactive care and regular inspections are essential. Periodic inspection and quality control tests must be scheduled. Remote control of the scanners by the manufacturer may also be helpful.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Ultrasound
Journal of Ultrasound RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.10
自引率
15.00%
发文量
133
期刊介绍: The Journal of Ultrasound is the official journal of the Italian Society for Ultrasound in Medicine and Biology (SIUMB). The journal publishes original contributions (research and review articles, case reports, technical reports and letters to the editor) on significant advances in clinical diagnostic, interventional and therapeutic applications, clinical techniques, the physics, engineering and technology of ultrasound in medicine and biology, and in cross-sectional diagnostic imaging. The official language of Journal of Ultrasound is English.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信