{"title":"血浆成纤维细胞生长因子21酶联免疫吸附测定试剂盒在脂肪肝疾病中的分析和临床验证","authors":"Makito Tanaka, Shingo Tanaka, Ryo Kobayashi, Ryosei Murai, Satoshi Takahashi","doi":"10.3390/biom15060877","DOIUrl":null,"url":null,"abstract":"<p><p>Steatotic liver disease is a global health challenge that requires reliable and noninvasive diagnostic biomarkers. This research aimed to validate the analytical and clinical performance of a fibroblast growth factor 21 (FGF21) enzyme-linked immunosorbent assay (ELISA) kit using an automated immunoassay analyzer. Plasma FGF21 levels were measured using a commercial ELISA kit on an automated immunoassay analyzer. Validation included intra- and inter-assay precision, dilution linearity, spike recovery, lower limit of quantification (LLOQ), interference testing, and sample stability analysis. Clinical evaluation involved 97 patients who underwent abdominal ultrasound-based attenuation imaging for the diagnosis of hepatic steatosis. The assay demonstrated high analytical precision, with intra- and inter-assay coefficients of variation <15% and an LLOQ of 3.260 pg/mL. Dilution linearity, spike recovery, and interference tests confirmed the reliability of the assay, whereas stability tests highlighted the minimal effect of freeze-thaw cycles and storage conditions. Clinically, FGF21 levels correlated with attenuation coefficient (<i>r</i> = 0.44). Diagnostic performance indicated 84% sensitivity and 81% specificity at defined FGF21 thresholds for the diagnosis of hepatic steatosis. This research confirmed the reliable analytical and clinical performance of the FGF21 ELISA kit, reinforcing its potential as a diagnostic biomarker of hepatic steatosis.</p>","PeriodicalId":8943,"journal":{"name":"Biomolecules","volume":"15 6","pages":""},"PeriodicalIF":4.8000,"publicationDate":"2025-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12190780/pdf/","citationCount":"0","resultStr":"{\"title\":\"Analytical and Clinical Validation of a Plasma Fibroblast Growth Factor 21 ELISA Kit Using an Automated Platform in Steatotic Liver Disease.\",\"authors\":\"Makito Tanaka, Shingo Tanaka, Ryo Kobayashi, Ryosei Murai, Satoshi Takahashi\",\"doi\":\"10.3390/biom15060877\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Steatotic liver disease is a global health challenge that requires reliable and noninvasive diagnostic biomarkers. This research aimed to validate the analytical and clinical performance of a fibroblast growth factor 21 (FGF21) enzyme-linked immunosorbent assay (ELISA) kit using an automated immunoassay analyzer. Plasma FGF21 levels were measured using a commercial ELISA kit on an automated immunoassay analyzer. Validation included intra- and inter-assay precision, dilution linearity, spike recovery, lower limit of quantification (LLOQ), interference testing, and sample stability analysis. Clinical evaluation involved 97 patients who underwent abdominal ultrasound-based attenuation imaging for the diagnosis of hepatic steatosis. The assay demonstrated high analytical precision, with intra- and inter-assay coefficients of variation <15% and an LLOQ of 3.260 pg/mL. Dilution linearity, spike recovery, and interference tests confirmed the reliability of the assay, whereas stability tests highlighted the minimal effect of freeze-thaw cycles and storage conditions. Clinically, FGF21 levels correlated with attenuation coefficient (<i>r</i> = 0.44). Diagnostic performance indicated 84% sensitivity and 81% specificity at defined FGF21 thresholds for the diagnosis of hepatic steatosis. This research confirmed the reliable analytical and clinical performance of the FGF21 ELISA kit, reinforcing its potential as a diagnostic biomarker of hepatic steatosis.</p>\",\"PeriodicalId\":8943,\"journal\":{\"name\":\"Biomolecules\",\"volume\":\"15 6\",\"pages\":\"\"},\"PeriodicalIF\":4.8000,\"publicationDate\":\"2025-06-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12190780/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomolecules\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.3390/biom15060877\",\"RegionNum\":2,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMISTRY & MOLECULAR BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomolecules","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.3390/biom15060877","RegionNum":2,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
Analytical and Clinical Validation of a Plasma Fibroblast Growth Factor 21 ELISA Kit Using an Automated Platform in Steatotic Liver Disease.
Steatotic liver disease is a global health challenge that requires reliable and noninvasive diagnostic biomarkers. This research aimed to validate the analytical and clinical performance of a fibroblast growth factor 21 (FGF21) enzyme-linked immunosorbent assay (ELISA) kit using an automated immunoassay analyzer. Plasma FGF21 levels were measured using a commercial ELISA kit on an automated immunoassay analyzer. Validation included intra- and inter-assay precision, dilution linearity, spike recovery, lower limit of quantification (LLOQ), interference testing, and sample stability analysis. Clinical evaluation involved 97 patients who underwent abdominal ultrasound-based attenuation imaging for the diagnosis of hepatic steatosis. The assay demonstrated high analytical precision, with intra- and inter-assay coefficients of variation <15% and an LLOQ of 3.260 pg/mL. Dilution linearity, spike recovery, and interference tests confirmed the reliability of the assay, whereas stability tests highlighted the minimal effect of freeze-thaw cycles and storage conditions. Clinically, FGF21 levels correlated with attenuation coefficient (r = 0.44). Diagnostic performance indicated 84% sensitivity and 81% specificity at defined FGF21 thresholds for the diagnosis of hepatic steatosis. This research confirmed the reliable analytical and clinical performance of the FGF21 ELISA kit, reinforcing its potential as a diagnostic biomarker of hepatic steatosis.
BiomoleculesBiochemistry, Genetics and Molecular Biology-Molecular Biology
CiteScore
9.40
自引率
3.60%
发文量
1640
审稿时长
18.28 days
期刊介绍:
Biomolecules (ISSN 2218-273X) is an international, peer-reviewed open access journal focusing on biogenic substances and their biological functions, structures, interactions with other molecules, and their microenvironment as well as biological systems. Biomolecules publishes reviews, regular research papers and short communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.