经导管Triclip修复三尖瓣成功指南。

Craig Basman, Polydoros Kampkatsis, Sung-Han Yoon, Perry Wengrofsky, Jessica Willert, Ryan Kaple
{"title":"经导管Triclip修复三尖瓣成功指南。","authors":"Craig Basman, Polydoros Kampkatsis, Sung-Han Yoon, Perry Wengrofsky, Jessica Willert, Ryan Kaple","doi":"10.1002/ccd.31693","DOIUrl":null,"url":null,"abstract":"<p><p>The use of transcatheter edge-to-edge repair (t-TEER) for tricuspid regurgitation (TR) continues to grow due to its proven clinical results and high safety profile. Yet, because the tricuspid valve is a complex and heterogenous valve, the results of recent landmark t-TEER trials may be difficult to replicate in daily practice as the use of t-TEER expands. Hence, this review is design to review optimal steps and advanced maneuvers for the Triclip (Abbott, MN, Minneapolis), which is the first United States regulatory approved device for t-TEER.</p>","PeriodicalId":520583,"journal":{"name":"Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Guide for Successful Transcatheter Tricuspid Valve Repair With the Triclip.\",\"authors\":\"Craig Basman, Polydoros Kampkatsis, Sung-Han Yoon, Perry Wengrofsky, Jessica Willert, Ryan Kaple\",\"doi\":\"10.1002/ccd.31693\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The use of transcatheter edge-to-edge repair (t-TEER) for tricuspid regurgitation (TR) continues to grow due to its proven clinical results and high safety profile. Yet, because the tricuspid valve is a complex and heterogenous valve, the results of recent landmark t-TEER trials may be difficult to replicate in daily practice as the use of t-TEER expands. Hence, this review is design to review optimal steps and advanced maneuvers for the Triclip (Abbott, MN, Minneapolis), which is the first United States regulatory approved device for t-TEER.</p>\",\"PeriodicalId\":520583,\"journal\":{\"name\":\"Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/ccd.31693\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/ccd.31693","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于经证实的临床效果和高安全性,经导管边缘到边缘修复(t-TEER)治疗三尖瓣反流(TR)的应用持续增长。然而,由于三尖瓣是一个复杂的异质瓣膜,随着t-TEER应用的扩大,最近具有里程碑意义的t-TEER试验的结果可能难以在日常实践中复制。因此,本综述旨在回顾Triclip (Abbott, MN, Minneapolis)的最佳步骤和先进操作,这是美国监管部门批准的第一个t-TEER设备。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Guide for Successful Transcatheter Tricuspid Valve Repair With the Triclip.

The use of transcatheter edge-to-edge repair (t-TEER) for tricuspid regurgitation (TR) continues to grow due to its proven clinical results and high safety profile. Yet, because the tricuspid valve is a complex and heterogenous valve, the results of recent landmark t-TEER trials may be difficult to replicate in daily practice as the use of t-TEER expands. Hence, this review is design to review optimal steps and advanced maneuvers for the Triclip (Abbott, MN, Minneapolis), which is the first United States regulatory approved device for t-TEER.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信