丝状真菌的鉴定:三种MALDI-TOF质谱系统的评价。

IF 3.1 2区 医学 Q1 DERMATOLOGY
Mycoses Pub Date : 2025-06-01 DOI:10.1111/myc.70078
Isabel Klugherz, Bettina Kölli, Moritz Reinmüller, Birgit Willinger, Eva Leitner, Ivo Steinmetz, Karl Dichtl
{"title":"丝状真菌的鉴定:三种MALDI-TOF质谱系统的评价。","authors":"Isabel Klugherz, Bettina Kölli, Moritz Reinmüller, Birgit Willinger, Eva Leitner, Ivo Steinmetz, Karl Dichtl","doi":"10.1111/myc.70078","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Identification of filamentous fungi still poses a major challenge to laboratories. Matrix assisted laser desorption/ionisation time of flight mass spectrometry (MALDI-TOF MS) is a promising tool, since it offers low-cost and fast results. Different MALDI-TOF MS systems are available for routine laboratories. This is a comprehensive head-to-head comparison of three devices and the respective reference spectrum databases.</p><p><strong>Materials and methods: </strong>A set of 77 pre-characterised isolates of filamentous fungi was measured (in duplicates) parallelly with three MALDI-TOF MS systems after 24 h, 48 h and 72 h of incubation: (1) Biotyper smart ('BT', Bruker Daltonics),(2) EXS2600 ('EXS', Zybio) and (3) VITEK MS PRIME ('VITEK', bioMérieux).</p><p><strong>Results: </strong>After three measurements, no valid results at the species level ('green category') were obtained for 18%, 21% and 14% of isolates by BT, EXS and VITEK. Depending on the MALDI-TOF MS system, validity rates ranged from 58%-82% for the different time points. Correct and valid results were obtained for 82%, 73% and 81% of isolates by BT, EXS and VITEK. BT was the system that required the most duplicate measurements. EXS displayed the highest rate of misidentification events. VITEK had the highest rate of unidentified isolates, which were featured within its database.</p><p><strong>Conclusion: </strong>Based on our experience, all three devices proved to be suitable for routine diagnostics. The timepoint of measurement had a major impact on the quality of analysis and should be considered by the user. Lowering the validity cut-off levels might increase the performance of the EXS system.</p>","PeriodicalId":18797,"journal":{"name":"Mycoses","volume":"68 6","pages":"e70078"},"PeriodicalIF":3.1000,"publicationDate":"2025-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12203145/pdf/","citationCount":"0","resultStr":"{\"title\":\"Identification of Filamentous Fungi: An Evaluation of Three MALDI-TOF Mass Spectrometry Systems.\",\"authors\":\"Isabel Klugherz, Bettina Kölli, Moritz Reinmüller, Birgit Willinger, Eva Leitner, Ivo Steinmetz, Karl Dichtl\",\"doi\":\"10.1111/myc.70078\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Identification of filamentous fungi still poses a major challenge to laboratories. Matrix assisted laser desorption/ionisation time of flight mass spectrometry (MALDI-TOF MS) is a promising tool, since it offers low-cost and fast results. Different MALDI-TOF MS systems are available for routine laboratories. This is a comprehensive head-to-head comparison of three devices and the respective reference spectrum databases.</p><p><strong>Materials and methods: </strong>A set of 77 pre-characterised isolates of filamentous fungi was measured (in duplicates) parallelly with three MALDI-TOF MS systems after 24 h, 48 h and 72 h of incubation: (1) Biotyper smart ('BT', Bruker Daltonics),(2) EXS2600 ('EXS', Zybio) and (3) VITEK MS PRIME ('VITEK', bioMérieux).</p><p><strong>Results: </strong>After three measurements, no valid results at the species level ('green category') were obtained for 18%, 21% and 14% of isolates by BT, EXS and VITEK. Depending on the MALDI-TOF MS system, validity rates ranged from 58%-82% for the different time points. Correct and valid results were obtained for 82%, 73% and 81% of isolates by BT, EXS and VITEK. BT was the system that required the most duplicate measurements. EXS displayed the highest rate of misidentification events. VITEK had the highest rate of unidentified isolates, which were featured within its database.</p><p><strong>Conclusion: </strong>Based on our experience, all three devices proved to be suitable for routine diagnostics. The timepoint of measurement had a major impact on the quality of analysis and should be considered by the user. Lowering the validity cut-off levels might increase the performance of the EXS system.</p>\",\"PeriodicalId\":18797,\"journal\":{\"name\":\"Mycoses\",\"volume\":\"68 6\",\"pages\":\"e70078\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2025-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12203145/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Mycoses\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/myc.70078\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DERMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mycoses","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/myc.70078","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DERMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:丝状真菌的鉴定仍然是实验室面临的主要挑战。基质辅助激光解吸/电离飞行时间质谱(MALDI-TOF MS)是一种很有前途的工具,因为它提供了低成本和快速的结果。不同的MALDI-TOF质谱系统可用于常规实验室。这是一个全面的头对头比较三个设备和各自的参考频谱数据库。材料和方法:在孵育24小时、48小时和72小时后,用3个MALDI-TOF质谱系统平行测量77个预表征的丝状真菌分离物:(1)Biotyper smart ('BT', Bruker Daltonics),(2) EXS2600 ('EXS', Zybio)和(3)VITEK MS PRIME ('VITEK', biom rieux)。结果:经三次检测,BT、EXS和VITEK法分别检测18%、21%和14%的分离株均未获得物种水平(“绿色类别”)的有效结果。根据MALDI-TOF MS系统,不同时间点的效度在58%-82%之间。BT法、EXS法和VITEK法对分离株的正确率分别为82%、73%和81%。BT是需要重复测量最多的系统。EXS的误认率最高。VITEK具有最高的未识别分离株率,这些分离株在其数据库中具有特色。结论:根据我们的经验,这三种设备都适用于常规诊断。测量的时间点对分析的质量有很大的影响,应该被用户考虑。降低有效性截止水平可能会提高EXS系统的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Identification of Filamentous Fungi: An Evaluation of Three MALDI-TOF Mass Spectrometry Systems.

Identification of Filamentous Fungi: An Evaluation of Three MALDI-TOF Mass Spectrometry Systems.

Identification of Filamentous Fungi: An Evaluation of Three MALDI-TOF Mass Spectrometry Systems.

Identification of Filamentous Fungi: An Evaluation of Three MALDI-TOF Mass Spectrometry Systems.

Background: Identification of filamentous fungi still poses a major challenge to laboratories. Matrix assisted laser desorption/ionisation time of flight mass spectrometry (MALDI-TOF MS) is a promising tool, since it offers low-cost and fast results. Different MALDI-TOF MS systems are available for routine laboratories. This is a comprehensive head-to-head comparison of three devices and the respective reference spectrum databases.

Materials and methods: A set of 77 pre-characterised isolates of filamentous fungi was measured (in duplicates) parallelly with three MALDI-TOF MS systems after 24 h, 48 h and 72 h of incubation: (1) Biotyper smart ('BT', Bruker Daltonics),(2) EXS2600 ('EXS', Zybio) and (3) VITEK MS PRIME ('VITEK', bioMérieux).

Results: After three measurements, no valid results at the species level ('green category') were obtained for 18%, 21% and 14% of isolates by BT, EXS and VITEK. Depending on the MALDI-TOF MS system, validity rates ranged from 58%-82% for the different time points. Correct and valid results were obtained for 82%, 73% and 81% of isolates by BT, EXS and VITEK. BT was the system that required the most duplicate measurements. EXS displayed the highest rate of misidentification events. VITEK had the highest rate of unidentified isolates, which were featured within its database.

Conclusion: Based on our experience, all three devices proved to be suitable for routine diagnostics. The timepoint of measurement had a major impact on the quality of analysis and should be considered by the user. Lowering the validity cut-off levels might increase the performance of the EXS system.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Mycoses
Mycoses 医学-皮肤病学
CiteScore
10.00
自引率
8.20%
发文量
143
审稿时长
6-12 weeks
期刊介绍: The journal Mycoses provides an international forum for original papers in English on the pathogenesis, diagnosis, therapy, prophylaxis, and epidemiology of fungal infectious diseases in humans as well as on the biology of pathogenic fungi. Medical mycology as part of medical microbiology is advancing rapidly. Effective therapeutic strategies are already available in chemotherapy and are being further developed. Their application requires reliable laboratory diagnostic techniques, which, in turn, result from mycological basic research. Opportunistic mycoses vary greatly in their clinical and pathological symptoms, because the underlying disease of a patient at risk decisively determines their symptomatology and progress. The journal Mycoses is therefore of interest to scientists in fundamental mycological research, mycological laboratory diagnosticians and clinicians interested in fungal infections.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信