{"title":"加热后预应力钢纤维混凝土短柱压缩性能:新混凝土压缩技术的影响","authors":"Manouchehr Nemati , Arman Aminian , Sepideh Rahimi , Mahdi Nematzadeh , Mobin Jafarzadeh-Taleshi , Huu-Tai Thai","doi":"10.1016/j.cscm.2025.e04968","DOIUrl":null,"url":null,"abstract":"<div><div>One innovative and effective technique to enhance the compression response of concrete-filled steel tube (CFST) columns is the compression of the fresh concrete, which actively confines the concrete core by prestressed steel tubes. To utilize active confinement in structural design, the behavior of prestressed CFST columns under different conditions should be investigated. In this research, the compression response of steel fiber-reinforced concrete-filled steel tube (SFRCFST) stub columns prestressed by the fresh concrete compression (FCC) technique was assessed before and after experiencing heat. Toward this goal, 60 cylindrical SFRCFST specimens were fabricated, with key variables of the prestressing ratio, volume percentage of steel fibers, applied temperature, external diameter-to-wall thickness ratio (D/t) of steel tube, and water/cement ratio. Post-heating axial compression tests examined the loading capacity, ductility, peak strain, toughness, and load-strain response. It was revealed that due to prestressing and the temperature rise to 600 °C, the heat-induced reduction in load capacity was negligible, while this drop was notable in the specimens without prestressing. At a temperature of 600°C, the load-bearing capacity of the specimens with a prestressing ratio of 0.5 <em>f</em><sub><em>y</em></sub> increased by 40 % compared to the non-confined specimens, while the axial and lateral strain capacities decreased by 40 and 49 %, respectively. With an increase in the prestressing ratio to 0.7 <em>f</em><sub><em>y</em></sub>, the load-bearing capacity increased by 50 %, and the axial and lateral strain capacities decreased by 26 and 25 %, respectively. In prestressed and non-prestressed SFRCFST columns, with or without thermal exposure, a steel fiber content of up to 1.5 % improved toughness and increased peak strain and ductility in most specimens. Finally, the nonlinear regression analysis was employed to present a proper prediction model for the loading capacity of SFRCFST columns.</div></div>","PeriodicalId":9641,"journal":{"name":"Case Studies in Construction Materials","volume":"23 ","pages":"Article e04968"},"PeriodicalIF":6.5000,"publicationDate":"2025-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Compressive behavior of prestressed SFRCFST stub columns after heating: Effect of fresh concrete compression technique\",\"authors\":\"Manouchehr Nemati , Arman Aminian , Sepideh Rahimi , Mahdi Nematzadeh , Mobin Jafarzadeh-Taleshi , Huu-Tai Thai\",\"doi\":\"10.1016/j.cscm.2025.e04968\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>One innovative and effective technique to enhance the compression response of concrete-filled steel tube (CFST) columns is the compression of the fresh concrete, which actively confines the concrete core by prestressed steel tubes. To utilize active confinement in structural design, the behavior of prestressed CFST columns under different conditions should be investigated. In this research, the compression response of steel fiber-reinforced concrete-filled steel tube (SFRCFST) stub columns prestressed by the fresh concrete compression (FCC) technique was assessed before and after experiencing heat. Toward this goal, 60 cylindrical SFRCFST specimens were fabricated, with key variables of the prestressing ratio, volume percentage of steel fibers, applied temperature, external diameter-to-wall thickness ratio (D/t) of steel tube, and water/cement ratio. Post-heating axial compression tests examined the loading capacity, ductility, peak strain, toughness, and load-strain response. It was revealed that due to prestressing and the temperature rise to 600 °C, the heat-induced reduction in load capacity was negligible, while this drop was notable in the specimens without prestressing. At a temperature of 600°C, the load-bearing capacity of the specimens with a prestressing ratio of 0.5 <em>f</em><sub><em>y</em></sub> increased by 40 % compared to the non-confined specimens, while the axial and lateral strain capacities decreased by 40 and 49 %, respectively. With an increase in the prestressing ratio to 0.7 <em>f</em><sub><em>y</em></sub>, the load-bearing capacity increased by 50 %, and the axial and lateral strain capacities decreased by 26 and 25 %, respectively. In prestressed and non-prestressed SFRCFST columns, with or without thermal exposure, a steel fiber content of up to 1.5 % improved toughness and increased peak strain and ductility in most specimens. Finally, the nonlinear regression analysis was employed to present a proper prediction model for the loading capacity of SFRCFST columns.</div></div>\",\"PeriodicalId\":9641,\"journal\":{\"name\":\"Case Studies in Construction Materials\",\"volume\":\"23 \",\"pages\":\"Article e04968\"},\"PeriodicalIF\":6.5000,\"publicationDate\":\"2025-06-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Case Studies in Construction Materials\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2214509525007661\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Studies in Construction Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214509525007661","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
Compressive behavior of prestressed SFRCFST stub columns after heating: Effect of fresh concrete compression technique
One innovative and effective technique to enhance the compression response of concrete-filled steel tube (CFST) columns is the compression of the fresh concrete, which actively confines the concrete core by prestressed steel tubes. To utilize active confinement in structural design, the behavior of prestressed CFST columns under different conditions should be investigated. In this research, the compression response of steel fiber-reinforced concrete-filled steel tube (SFRCFST) stub columns prestressed by the fresh concrete compression (FCC) technique was assessed before and after experiencing heat. Toward this goal, 60 cylindrical SFRCFST specimens were fabricated, with key variables of the prestressing ratio, volume percentage of steel fibers, applied temperature, external diameter-to-wall thickness ratio (D/t) of steel tube, and water/cement ratio. Post-heating axial compression tests examined the loading capacity, ductility, peak strain, toughness, and load-strain response. It was revealed that due to prestressing and the temperature rise to 600 °C, the heat-induced reduction in load capacity was negligible, while this drop was notable in the specimens without prestressing. At a temperature of 600°C, the load-bearing capacity of the specimens with a prestressing ratio of 0.5 fy increased by 40 % compared to the non-confined specimens, while the axial and lateral strain capacities decreased by 40 and 49 %, respectively. With an increase in the prestressing ratio to 0.7 fy, the load-bearing capacity increased by 50 %, and the axial and lateral strain capacities decreased by 26 and 25 %, respectively. In prestressed and non-prestressed SFRCFST columns, with or without thermal exposure, a steel fiber content of up to 1.5 % improved toughness and increased peak strain and ductility in most specimens. Finally, the nonlinear regression analysis was employed to present a proper prediction model for the loading capacity of SFRCFST columns.
期刊介绍:
Case Studies in Construction Materials provides a forum for the rapid publication of short, structured Case Studies on construction materials. In addition, the journal also publishes related Short Communications, Full length research article and Comprehensive review papers (by invitation).
The journal will provide an essential compendium of case studies for practicing engineers, designers, researchers and other practitioners who are interested in all aspects construction materials. The journal will publish new and novel case studies, but will also provide a forum for the publication of high quality descriptions of classic construction material problems and solutions.