空心加压螺钉置入猪股骨颈骨折保护主要骨内动脉

IF 0.8 4区 农林科学 Q4 ANATOMY & MORPHOLOGY
Dingsong Wang, Wen Ju, Linfeng Tang, Wei Deng, Jiaming Wan, Faxin Ju, Jihui Ju, Yingying Le, Lei Li, Ruixing Hou
{"title":"空心加压螺钉置入猪股骨颈骨折保护主要骨内动脉","authors":"Dingsong Wang,&nbsp;Wen Ju,&nbsp;Linfeng Tang,&nbsp;Wei Deng,&nbsp;Jiaming Wan,&nbsp;Faxin Ju,&nbsp;Jihui Ju,&nbsp;Yingying Le,&nbsp;Lei Li,&nbsp;Ruixing Hou","doi":"10.1111/ahe.70052","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>Femoral head necrosis is a common and serious complication of femoral neck fractures, primarily attributed to disrupted blood supply. This study introduces a novel method of placing cannulated compression screws in swine femoral neck fractures, designed to protect the blood supply to the femoral head while ensuring mechanical stability. Using microscopic perfusion techniques and 3D technology (via Materialise 3-Matic11.0 and Materialise Magics 21.0 software), we created perfusion and corrosion casting specimens of the intraosseous arteries from 21 fresh swine proximal femurs. The spatial distribution of the arteries was analyzed, and screw placement simulations were conducted on 3D scans to avoid damaging the main intraosseous arteries. Two screws were then placed on real casting specimens, resulting in minimal arterial damage. Biomechanical tests on 16 femoral neck fracture models showed no significant differences between the new method and the traditional two-screw method in terms of compression strength and maximal vertical loading. This study demonstrates an innovative screw placement technique that effectively protects the blood supply to the femoral head while maintaining mechanical stability comparable to traditional methods. The clinical implications are significant—this approach could reduce the incidence of femoral head necrosis, improve patient outcomes and decrease related complications. By balancing blood supply preservation with mechanical stability, this method offers a promising strategy for the management of femoral neck fractures.</p>\n </div>","PeriodicalId":49290,"journal":{"name":"Anatomia Histologia Embryologia","volume":"54 4","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2025-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cannulated Compression Screw Placement for Swine Femoral Neck Fracture to Protect the Main Intraosseous Arteries\",\"authors\":\"Dingsong Wang,&nbsp;Wen Ju,&nbsp;Linfeng Tang,&nbsp;Wei Deng,&nbsp;Jiaming Wan,&nbsp;Faxin Ju,&nbsp;Jihui Ju,&nbsp;Yingying Le,&nbsp;Lei Li,&nbsp;Ruixing Hou\",\"doi\":\"10.1111/ahe.70052\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <p>Femoral head necrosis is a common and serious complication of femoral neck fractures, primarily attributed to disrupted blood supply. This study introduces a novel method of placing cannulated compression screws in swine femoral neck fractures, designed to protect the blood supply to the femoral head while ensuring mechanical stability. Using microscopic perfusion techniques and 3D technology (via Materialise 3-Matic11.0 and Materialise Magics 21.0 software), we created perfusion and corrosion casting specimens of the intraosseous arteries from 21 fresh swine proximal femurs. The spatial distribution of the arteries was analyzed, and screw placement simulations were conducted on 3D scans to avoid damaging the main intraosseous arteries. Two screws were then placed on real casting specimens, resulting in minimal arterial damage. Biomechanical tests on 16 femoral neck fracture models showed no significant differences between the new method and the traditional two-screw method in terms of compression strength and maximal vertical loading. This study demonstrates an innovative screw placement technique that effectively protects the blood supply to the femoral head while maintaining mechanical stability comparable to traditional methods. The clinical implications are significant—this approach could reduce the incidence of femoral head necrosis, improve patient outcomes and decrease related complications. By balancing blood supply preservation with mechanical stability, this method offers a promising strategy for the management of femoral neck fractures.</p>\\n </div>\",\"PeriodicalId\":49290,\"journal\":{\"name\":\"Anatomia Histologia Embryologia\",\"volume\":\"54 4\",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2025-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Anatomia Histologia Embryologia\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/ahe.70052\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ANATOMY & MORPHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anatomia Histologia Embryologia","FirstCategoryId":"97","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/ahe.70052","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ANATOMY & MORPHOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

股骨头坏死是股骨颈骨折常见且严重的并发症,主要是由于血液供应中断。本研究介绍了一种放置空心加压螺钉治疗猪股骨颈骨折的新方法,旨在保护股骨头的血液供应,同时确保机械稳定性。使用显微灌注技术和3D技术(通过Materialise 3-Matic11.0和Materialise Magics 21.0软件),我们创建了21根新鲜猪股骨近端骨内动脉的灌注和腐蚀铸造标本。分析动脉的空间分布,并在3D扫描上进行螺钉放置模拟,以避免损伤骨内主要动脉。然后将两颗螺钉放在真实的铸造标本上,使动脉损伤最小。对16个股骨颈骨折模型的生物力学试验表明,新方法与传统双螺钉方法在抗压强度和最大垂直载荷方面无显著差异。本研究展示了一种创新的螺钉置入技术,该技术可以有效地保护股骨头的血液供应,同时保持与传统方法相当的机械稳定性。临床意义显著,该入路可减少股骨头坏死的发生率,改善患者预后,减少相关并发症。通过平衡血液供应和机械稳定性,这种方法为股骨颈骨折的治疗提供了一种很有前途的策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Cannulated Compression Screw Placement for Swine Femoral Neck Fracture to Protect the Main Intraosseous Arteries

Femoral head necrosis is a common and serious complication of femoral neck fractures, primarily attributed to disrupted blood supply. This study introduces a novel method of placing cannulated compression screws in swine femoral neck fractures, designed to protect the blood supply to the femoral head while ensuring mechanical stability. Using microscopic perfusion techniques and 3D technology (via Materialise 3-Matic11.0 and Materialise Magics 21.0 software), we created perfusion and corrosion casting specimens of the intraosseous arteries from 21 fresh swine proximal femurs. The spatial distribution of the arteries was analyzed, and screw placement simulations were conducted on 3D scans to avoid damaging the main intraosseous arteries. Two screws were then placed on real casting specimens, resulting in minimal arterial damage. Biomechanical tests on 16 femoral neck fracture models showed no significant differences between the new method and the traditional two-screw method in terms of compression strength and maximal vertical loading. This study demonstrates an innovative screw placement technique that effectively protects the blood supply to the femoral head while maintaining mechanical stability comparable to traditional methods. The clinical implications are significant—this approach could reduce the incidence of femoral head necrosis, improve patient outcomes and decrease related complications. By balancing blood supply preservation with mechanical stability, this method offers a promising strategy for the management of femoral neck fractures.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Anatomia Histologia Embryologia
Anatomia Histologia Embryologia ANATOMY & MORPHOLOGY-VETERINARY SCIENCES
CiteScore
1.90
自引率
11.10%
发文量
115
审稿时长
18-36 weeks
期刊介绍: Anatomia, Histologia, Embryologia is a premier international forum for the latest research on descriptive, applied and clinical anatomy, histology, embryology, and related fields. Special emphasis is placed on the links between animal morphology and veterinary and experimental medicine, consequently studies on clinically relevant species will be given priority. The editors welcome papers on medical imaging and anatomical techniques. The journal is of vital interest to clinicians, zoologists, obstetricians, and researchers working in biotechnology. Contributions include reviews, original research articles, short communications and book reviews.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信