Oriana Cuman , Federico Toselli , Guido Viel , Paolo Fais , Maria Sech , Chiara Giraudo , Francesco Bertelli , Vladimiro Vida , Giovanni Cecchetto
{"title":"显微放射学分析和3d打印椎骨在刺伤杀人案中的法医应用","authors":"Oriana Cuman , Federico Toselli , Guido Viel , Paolo Fais , Maria Sech , Chiara Giraudo , Francesco Bertelli , Vladimiro Vida , Giovanni Cecchetto","doi":"10.1016/j.legalmed.2025.102661","DOIUrl":null,"url":null,"abstract":"<div><div>Stab injuries involving the vertebral region are rare and pose significant challenges during forensic autopsy due to the complexity of the surrounding anatomical structures. Radiological techniques, such as post-mortem computed tomography (PMCT) or micro-CT, have shown great potential for detecting and detailing sharp bone lesions. We herein present a fatal case of homicidal stab wound involving the left vertebral artery and the homolateral surface of the axis. PMCT identified a fracture of the left lateral mass of the axis (C2), and micro-CT revealed a cortical discontinuity of the left transverse process of C2, nearly separating the transverse process from the body of the axis. Based on micro-CT data, a 3D model of the first three cervical vertebrae was printed in a clear material on a Formlabs Form 3L printer, and a fit-matching analysis was conducted with two potential weapons. The billhook seized by the Police demonstrated a precise fit with the fracture pattern when its handle was positioned posteriorly, and the tip penetrated laterally in a left-to-right trajectory.</div><div>In conclusion, to the best of our knowledge, this is the first report of vertebral stab wound analysis using a combined micro-CT and 3D printing approach.</div><div>Although 3D printing is not yet a fully validated forensic method, and further research is needed for identifying any potential errors occurring during production, segmentation, stereolithography data generation, and post-processing, this report highlights the high potentiality of micro-radiology and 3D printing as promising tools for the morphometric analysis of vertebral injuries.</div></div>","PeriodicalId":49913,"journal":{"name":"Legal Medicine","volume":"76 ","pages":"Article 102661"},"PeriodicalIF":1.3000,"publicationDate":"2025-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Forensic application of micro-radiological analysis and 3D-printed vertebrae in a stab wound homicide case\",\"authors\":\"Oriana Cuman , Federico Toselli , Guido Viel , Paolo Fais , Maria Sech , Chiara Giraudo , Francesco Bertelli , Vladimiro Vida , Giovanni Cecchetto\",\"doi\":\"10.1016/j.legalmed.2025.102661\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Stab injuries involving the vertebral region are rare and pose significant challenges during forensic autopsy due to the complexity of the surrounding anatomical structures. Radiological techniques, such as post-mortem computed tomography (PMCT) or micro-CT, have shown great potential for detecting and detailing sharp bone lesions. We herein present a fatal case of homicidal stab wound involving the left vertebral artery and the homolateral surface of the axis. PMCT identified a fracture of the left lateral mass of the axis (C2), and micro-CT revealed a cortical discontinuity of the left transverse process of C2, nearly separating the transverse process from the body of the axis. Based on micro-CT data, a 3D model of the first three cervical vertebrae was printed in a clear material on a Formlabs Form 3L printer, and a fit-matching analysis was conducted with two potential weapons. The billhook seized by the Police demonstrated a precise fit with the fracture pattern when its handle was positioned posteriorly, and the tip penetrated laterally in a left-to-right trajectory.</div><div>In conclusion, to the best of our knowledge, this is the first report of vertebral stab wound analysis using a combined micro-CT and 3D printing approach.</div><div>Although 3D printing is not yet a fully validated forensic method, and further research is needed for identifying any potential errors occurring during production, segmentation, stereolithography data generation, and post-processing, this report highlights the high potentiality of micro-radiology and 3D printing as promising tools for the morphometric analysis of vertebral injuries.</div></div>\",\"PeriodicalId\":49913,\"journal\":{\"name\":\"Legal Medicine\",\"volume\":\"76 \",\"pages\":\"Article 102661\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2025-06-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Legal Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1344622325000951\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, LEGAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Legal Medicine","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1344622325000951","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, LEGAL","Score":null,"Total":0}
引用次数: 0
摘要
由于周围解剖结构的复杂性,涉及椎体区域的刺伤是罕见的,并且在法医尸检中构成了重大挑战。放射学技术,如死后计算机断层扫描(PMCT)或微ct,在检测和详细描述尖锐骨病变方面显示出巨大的潜力。我们在此提出一个致命的情况下,杀人刺伤涉及左椎动脉和轴的同外侧表面。PMCT发现左侧椎轴侧块(C2)骨折,micro-CT显示左侧C2横突皮质不连续,几乎将横突与椎体分离。基于micro-CT数据,在Formlabs Form 3L打印机上以透明材料打印出前三节颈椎的三维模型,并与两种潜在武器进行拟合匹配分析。警方检获的鹰嘴钩,其柄位在后,刀尖沿从左至右的轨迹横向插入,与骨折模式吻合。综上所述,据我们所知,这是首个使用显微ct和3D打印相结合的方法分析椎体刺伤的报告。虽然3D打印还不是一种完全有效的法医方法,并且需要进一步研究以确定在生产、分割、立体光刻数据生成和后处理过程中发生的任何潜在错误,但该报告强调了微放射学和3D打印作为椎体损伤形态测量分析的有前途的工具的巨大潜力。
Forensic application of micro-radiological analysis and 3D-printed vertebrae in a stab wound homicide case
Stab injuries involving the vertebral region are rare and pose significant challenges during forensic autopsy due to the complexity of the surrounding anatomical structures. Radiological techniques, such as post-mortem computed tomography (PMCT) or micro-CT, have shown great potential for detecting and detailing sharp bone lesions. We herein present a fatal case of homicidal stab wound involving the left vertebral artery and the homolateral surface of the axis. PMCT identified a fracture of the left lateral mass of the axis (C2), and micro-CT revealed a cortical discontinuity of the left transverse process of C2, nearly separating the transverse process from the body of the axis. Based on micro-CT data, a 3D model of the first three cervical vertebrae was printed in a clear material on a Formlabs Form 3L printer, and a fit-matching analysis was conducted with two potential weapons. The billhook seized by the Police demonstrated a precise fit with the fracture pattern when its handle was positioned posteriorly, and the tip penetrated laterally in a left-to-right trajectory.
In conclusion, to the best of our knowledge, this is the first report of vertebral stab wound analysis using a combined micro-CT and 3D printing approach.
Although 3D printing is not yet a fully validated forensic method, and further research is needed for identifying any potential errors occurring during production, segmentation, stereolithography data generation, and post-processing, this report highlights the high potentiality of micro-radiology and 3D printing as promising tools for the morphometric analysis of vertebral injuries.
期刊介绍:
Legal Medicine provides an international forum for the publication of original articles, reviews and correspondence on subjects that cover practical and theoretical areas of interest relating to the wide range of legal medicine.
Subjects covered include forensic pathology, toxicology, odontology, anthropology, criminalistics, immunochemistry, hemogenetics and forensic aspects of biological science with emphasis on DNA analysis and molecular biology. Submissions dealing with medicolegal problems such as malpractice, insurance, child abuse or ethics in medical practice are also acceptable.