Beltrán-Murcia J, Álvarez-Rementería Capelo L, Blázquez-Sánchez V
{"title":"EVO ICL晶状体植入术中生物特征参数与内皮距离的相关性研究。","authors":"Beltrán-Murcia J, Álvarez-Rementería Capelo L, Blázquez-Sánchez V","doi":"10.1155/joph/6959314","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose:</b> The correlations between different parameters and the positioning of the EVO ICL were analyzed. Significant correlations were observed, highlighting the relationship between the endothelium and the anterior surface of the phakic ICL lens. However, it is important to note that GAP is only a postoperative measure and cannot be used to directly define the correct positioning of the EVO ICL. The study emphasizes these correlations, without drawing conclusions regarding the causal relationships between the parameters. <b>Methods:</b> In this retrospective, observational, transversal analytic study, patients who underwent refractive surgery with implanted EVO ICL pIOL were analyzed. The distance between corneal endothelium and anterior surface of ICL (GAP) was measured postoperatively at 1 week and 1 month using ANTERION AS-OCT. <b>Results:</b> 35 eyes of 35 patients were analyzed. The mean GAP values at 1 week and 1 month were 2.5 ± 0.2 mm and 2.6 ± 0.2 mm, respectively (<i>p</i> = 0.002), increasing its value. The GAP value correlated positively with preoperative anterior chamber volume, white-to-white, lens vault, spur-spur distance, anterior chamber angle distance, and anterior chamber angles values. <b>Conclusions:</b> The correlations between GAP and pre- and postoperative variables highlight its relationship with anterior segment anatomy after EVO ICL implantation. However, as a postoperative measurement, GAP does not determine the correct positioning of the lens.</p>","PeriodicalId":16674,"journal":{"name":"Journal of Ophthalmology","volume":"2025 ","pages":"6959314"},"PeriodicalIF":1.9000,"publicationDate":"2025-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12178738/pdf/","citationCount":"0","resultStr":"{\"title\":\"Correlation of Biometric Parameters With Endothelial Distance in EVO ICL Phakic Lens Implantation.\",\"authors\":\"Beltrán-Murcia J, Álvarez-Rementería Capelo L, Blázquez-Sánchez V\",\"doi\":\"10.1155/joph/6959314\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Purpose:</b> The correlations between different parameters and the positioning of the EVO ICL were analyzed. Significant correlations were observed, highlighting the relationship between the endothelium and the anterior surface of the phakic ICL lens. However, it is important to note that GAP is only a postoperative measure and cannot be used to directly define the correct positioning of the EVO ICL. The study emphasizes these correlations, without drawing conclusions regarding the causal relationships between the parameters. <b>Methods:</b> In this retrospective, observational, transversal analytic study, patients who underwent refractive surgery with implanted EVO ICL pIOL were analyzed. The distance between corneal endothelium and anterior surface of ICL (GAP) was measured postoperatively at 1 week and 1 month using ANTERION AS-OCT. <b>Results:</b> 35 eyes of 35 patients were analyzed. The mean GAP values at 1 week and 1 month were 2.5 ± 0.2 mm and 2.6 ± 0.2 mm, respectively (<i>p</i> = 0.002), increasing its value. The GAP value correlated positively with preoperative anterior chamber volume, white-to-white, lens vault, spur-spur distance, anterior chamber angle distance, and anterior chamber angles values. <b>Conclusions:</b> The correlations between GAP and pre- and postoperative variables highlight its relationship with anterior segment anatomy after EVO ICL implantation. However, as a postoperative measurement, GAP does not determine the correct positioning of the lens.</p>\",\"PeriodicalId\":16674,\"journal\":{\"name\":\"Journal of Ophthalmology\",\"volume\":\"2025 \",\"pages\":\"6959314\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2025-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12178738/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1155/joph/6959314\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/joph/6959314","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Correlation of Biometric Parameters With Endothelial Distance in EVO ICL Phakic Lens Implantation.
Purpose: The correlations between different parameters and the positioning of the EVO ICL were analyzed. Significant correlations were observed, highlighting the relationship between the endothelium and the anterior surface of the phakic ICL lens. However, it is important to note that GAP is only a postoperative measure and cannot be used to directly define the correct positioning of the EVO ICL. The study emphasizes these correlations, without drawing conclusions regarding the causal relationships between the parameters. Methods: In this retrospective, observational, transversal analytic study, patients who underwent refractive surgery with implanted EVO ICL pIOL were analyzed. The distance between corneal endothelium and anterior surface of ICL (GAP) was measured postoperatively at 1 week and 1 month using ANTERION AS-OCT. Results: 35 eyes of 35 patients were analyzed. The mean GAP values at 1 week and 1 month were 2.5 ± 0.2 mm and 2.6 ± 0.2 mm, respectively (p = 0.002), increasing its value. The GAP value correlated positively with preoperative anterior chamber volume, white-to-white, lens vault, spur-spur distance, anterior chamber angle distance, and anterior chamber angles values. Conclusions: The correlations between GAP and pre- and postoperative variables highlight its relationship with anterior segment anatomy after EVO ICL implantation. However, as a postoperative measurement, GAP does not determine the correct positioning of the lens.
期刊介绍:
Journal of Ophthalmology is a peer-reviewed, Open Access journal that publishes original research articles, review articles, and clinical studies related to the anatomy, physiology and diseases of the eye. Submissions should focus on new diagnostic and surgical techniques, instrument and therapy updates, as well as clinical trials and research findings.