Zhongzheng Wang, Han Shao, Alan O Riordan, Javier Higes-Marquez, Ivan O Connell, Daniel O Hare
{"title":"基于阻抗的生物医学应用中以方波为激励信号的快速电化学阻抗谱。","authors":"Zhongzheng Wang, Han Shao, Alan O Riordan, Javier Higes-Marquez, Ivan O Connell, Daniel O Hare","doi":"10.1109/TBCAS.2025.3579698","DOIUrl":null,"url":null,"abstract":"<p><p>This paper introduces a fast, high-accuracy methodology for conducting Electrochemical Impedance Spectroscopy (EIS) based on Fast Fourier Transform (FFT), to meet the requirements of portable, real-time biomedical impedance-based detections with Ultra-Microband (UMB) sensor. Instead of using white noise-like wideband signals as in conventional FFT-based EIS, the proposed method uses a square wave as the excitation signal, which achieves a fast, accurate EIS measurement, but no longer requires complex circuits like high-resolution DACs or frequency mixers for the signal generation. This work starts with the theoretical justification for treating the sensor as a Linear Time-Invariant (LTI), then the practical linear region for operating the sensor as an LTI system is experimentally verified and determined, which enables the capacity of employing the harmonics of a square wave for EIS measurements. A dynamic model of the charge-transfer resistance together with an approximated of the Constant Phase Element (CPE) are implemented with Verilog-A for simulations, and a circuit consisting of a control amplifier and a Trans-Impedance Amplifier (TIA) is designed and fabricated with 65 nm CMOS for validating its on-chip feasibility. This work shortens the EIS measurement time by 91.7% in a frequency sweep range from 0.5 Hz to 500 Hz, with only 2.73% average Mean Absolute Percentage Error (MAPE), compared to a commercial electrochemical instrument AutoLab, with five pre-modified electrodes across four different concentrations of Ferrocene Carboxylic Acid (FcCOOH), demonstrating this method is suitable for portable, real-time label-free EIS biomedical detections and applications.</p>","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":"PP ","pages":""},"PeriodicalIF":4.9000,"publicationDate":"2025-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Fast Electrochemical Impedance Spectroscopy with A Square Wave as Excitation Signal for Impedance-based Biomedical Applications.\",\"authors\":\"Zhongzheng Wang, Han Shao, Alan O Riordan, Javier Higes-Marquez, Ivan O Connell, Daniel O Hare\",\"doi\":\"10.1109/TBCAS.2025.3579698\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This paper introduces a fast, high-accuracy methodology for conducting Electrochemical Impedance Spectroscopy (EIS) based on Fast Fourier Transform (FFT), to meet the requirements of portable, real-time biomedical impedance-based detections with Ultra-Microband (UMB) sensor. Instead of using white noise-like wideband signals as in conventional FFT-based EIS, the proposed method uses a square wave as the excitation signal, which achieves a fast, accurate EIS measurement, but no longer requires complex circuits like high-resolution DACs or frequency mixers for the signal generation. This work starts with the theoretical justification for treating the sensor as a Linear Time-Invariant (LTI), then the practical linear region for operating the sensor as an LTI system is experimentally verified and determined, which enables the capacity of employing the harmonics of a square wave for EIS measurements. A dynamic model of the charge-transfer resistance together with an approximated of the Constant Phase Element (CPE) are implemented with Verilog-A for simulations, and a circuit consisting of a control amplifier and a Trans-Impedance Amplifier (TIA) is designed and fabricated with 65 nm CMOS for validating its on-chip feasibility. This work shortens the EIS measurement time by 91.7% in a frequency sweep range from 0.5 Hz to 500 Hz, with only 2.73% average Mean Absolute Percentage Error (MAPE), compared to a commercial electrochemical instrument AutoLab, with five pre-modified electrodes across four different concentrations of Ferrocene Carboxylic Acid (FcCOOH), demonstrating this method is suitable for portable, real-time label-free EIS biomedical detections and applications.</p>\",\"PeriodicalId\":94031,\"journal\":{\"name\":\"IEEE transactions on biomedical circuits and systems\",\"volume\":\"PP \",\"pages\":\"\"},\"PeriodicalIF\":4.9000,\"publicationDate\":\"2025-06-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE transactions on biomedical circuits and systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TBCAS.2025.3579698\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on biomedical circuits and systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TBCAS.2025.3579698","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Fast Electrochemical Impedance Spectroscopy with A Square Wave as Excitation Signal for Impedance-based Biomedical Applications.
This paper introduces a fast, high-accuracy methodology for conducting Electrochemical Impedance Spectroscopy (EIS) based on Fast Fourier Transform (FFT), to meet the requirements of portable, real-time biomedical impedance-based detections with Ultra-Microband (UMB) sensor. Instead of using white noise-like wideband signals as in conventional FFT-based EIS, the proposed method uses a square wave as the excitation signal, which achieves a fast, accurate EIS measurement, but no longer requires complex circuits like high-resolution DACs or frequency mixers for the signal generation. This work starts with the theoretical justification for treating the sensor as a Linear Time-Invariant (LTI), then the practical linear region for operating the sensor as an LTI system is experimentally verified and determined, which enables the capacity of employing the harmonics of a square wave for EIS measurements. A dynamic model of the charge-transfer resistance together with an approximated of the Constant Phase Element (CPE) are implemented with Verilog-A for simulations, and a circuit consisting of a control amplifier and a Trans-Impedance Amplifier (TIA) is designed and fabricated with 65 nm CMOS for validating its on-chip feasibility. This work shortens the EIS measurement time by 91.7% in a frequency sweep range from 0.5 Hz to 500 Hz, with only 2.73% average Mean Absolute Percentage Error (MAPE), compared to a commercial electrochemical instrument AutoLab, with five pre-modified electrodes across four different concentrations of Ferrocene Carboxylic Acid (FcCOOH), demonstrating this method is suitable for portable, real-time label-free EIS biomedical detections and applications.