人工耳蜗受者术中及术后的耳蜗电造影术:回顾性图表回顾。

IF 1.4 Q2 OTORHINOLARYNGOLOGY
Leonardo Elías Ordóñez Ordóñez, Esther Sofia Angulo Martinez, Silvia Carolina Vanegas, Estefany Catherine Hernández, Eduardo Peroza Fuentes, Robert T Dwyer, Ana Claudia Martinho-Carvalho
{"title":"人工耳蜗受者术中及术后的耳蜗电造影术:回顾性图表回顾。","authors":"Leonardo Elías Ordóñez Ordóñez, Esther Sofia Angulo Martinez, Silvia Carolina Vanegas, Estefany Catherine Hernández, Eduardo Peroza Fuentes, Robert T Dwyer, Ana Claudia Martinho-Carvalho","doi":"10.1080/14670100.2025.2515703","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The purpose of the study was (1) to retrospectively analyze ECochG data and compare it with the current literature. (2) to explore the relationship between ECochG and post-op audiological assessments.</p><p><strong>Methods: </strong>This retrospective study included all patients with intraoperative and postoperative ECochG measurements and postoperative audiologic testing. ECochG were performed during CI insertion regardless of the preoperative hearing status. Preoperative and postoperative assessments were extracted from the medical records.</p><p><strong>Results: </strong>A total of 35 patients (42 ears) met the inclusion criteria. Intra-op ECochG response was measurable in 17 of 42 ears (40.5%). The mean peak amplitude found was 103.3 µvolts. The type of electrode array was not associated with the ECochG amplitude (<i>p</i> = .630). Post-op ECochG thresholds were significantly correlated with behavioral thresholds after a month of CI implantation (<i>p</i> < 0.05).</p><p><strong>Conclusions: </strong>ECochG responses were measurable in individuals with mean preop pure tone thresholds of 66 dB HL at 250 Hz, 77 dB HL at 500 Hz, 84 dB HL at 1 kHz and 92 dB HL at 2kHz. The type of electrode was not associated with the ECochG peak nor with greater preservation of residual hearing. Post-op ECochG thresholds were significantly correlated with post-op thresholds.</p>","PeriodicalId":53553,"journal":{"name":"COCHLEAR IMPLANTS INTERNATIONAL","volume":" ","pages":"1-11"},"PeriodicalIF":1.4000,"publicationDate":"2025-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Intra and postoperative electrocochleography in cochlear implant recipients: retrospective chart review.\",\"authors\":\"Leonardo Elías Ordóñez Ordóñez, Esther Sofia Angulo Martinez, Silvia Carolina Vanegas, Estefany Catherine Hernández, Eduardo Peroza Fuentes, Robert T Dwyer, Ana Claudia Martinho-Carvalho\",\"doi\":\"10.1080/14670100.2025.2515703\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The purpose of the study was (1) to retrospectively analyze ECochG data and compare it with the current literature. (2) to explore the relationship between ECochG and post-op audiological assessments.</p><p><strong>Methods: </strong>This retrospective study included all patients with intraoperative and postoperative ECochG measurements and postoperative audiologic testing. ECochG were performed during CI insertion regardless of the preoperative hearing status. Preoperative and postoperative assessments were extracted from the medical records.</p><p><strong>Results: </strong>A total of 35 patients (42 ears) met the inclusion criteria. Intra-op ECochG response was measurable in 17 of 42 ears (40.5%). The mean peak amplitude found was 103.3 µvolts. The type of electrode array was not associated with the ECochG amplitude (<i>p</i> = .630). Post-op ECochG thresholds were significantly correlated with behavioral thresholds after a month of CI implantation (<i>p</i> < 0.05).</p><p><strong>Conclusions: </strong>ECochG responses were measurable in individuals with mean preop pure tone thresholds of 66 dB HL at 250 Hz, 77 dB HL at 500 Hz, 84 dB HL at 1 kHz and 92 dB HL at 2kHz. The type of electrode was not associated with the ECochG peak nor with greater preservation of residual hearing. Post-op ECochG thresholds were significantly correlated with post-op thresholds.</p>\",\"PeriodicalId\":53553,\"journal\":{\"name\":\"COCHLEAR IMPLANTS INTERNATIONAL\",\"volume\":\" \",\"pages\":\"1-11\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-06-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"COCHLEAR IMPLANTS INTERNATIONAL\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/14670100.2025.2515703\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OTORHINOLARYNGOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"COCHLEAR IMPLANTS INTERNATIONAL","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/14670100.2025.2515703","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究的目的是:(1)回顾性分析ECochG数据,并与现有文献进行比较。(2)探讨ECochG与术后听力学评估的关系。方法:回顾性研究包括术中和术后ECochG测量和术后听力学测试的所有患者。无论术前听力状况如何,在CI插入期间进行ECochG。术前和术后评估从医疗记录中提取。结果:35例患者(42耳)符合纳入标准。42只耳中有17只(40.5%)可测量术中ECochG反应。平均峰值振幅为103.3µv。电极排列类型与ECochG振幅无关(p = 0.630)。术后ECochG阈值与CI植入1个月后的行为阈值显著相关(p < 0.05)。结论:ECochG反应在平均术前纯音阈值为250 Hz时66 dB HL, 500 Hz时77 dB HL, 1 kHz时84 dB HL和2kHz时92 dB HL的个体中是可测量的。电极的类型与ECochG峰值无关,也与残余听力的保存无关。术后ECochG阈值与术后阈值显著相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Intra and postoperative electrocochleography in cochlear implant recipients: retrospective chart review.

Objectives: The purpose of the study was (1) to retrospectively analyze ECochG data and compare it with the current literature. (2) to explore the relationship between ECochG and post-op audiological assessments.

Methods: This retrospective study included all patients with intraoperative and postoperative ECochG measurements and postoperative audiologic testing. ECochG were performed during CI insertion regardless of the preoperative hearing status. Preoperative and postoperative assessments were extracted from the medical records.

Results: A total of 35 patients (42 ears) met the inclusion criteria. Intra-op ECochG response was measurable in 17 of 42 ears (40.5%). The mean peak amplitude found was 103.3 µvolts. The type of electrode array was not associated with the ECochG amplitude (p = .630). Post-op ECochG thresholds were significantly correlated with behavioral thresholds after a month of CI implantation (p < 0.05).

Conclusions: ECochG responses were measurable in individuals with mean preop pure tone thresholds of 66 dB HL at 250 Hz, 77 dB HL at 500 Hz, 84 dB HL at 1 kHz and 92 dB HL at 2kHz. The type of electrode was not associated with the ECochG peak nor with greater preservation of residual hearing. Post-op ECochG thresholds were significantly correlated with post-op thresholds.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
COCHLEAR IMPLANTS INTERNATIONAL
COCHLEAR IMPLANTS INTERNATIONAL Medicine-Otorhinolaryngology
CiteScore
3.10
自引率
0.00%
发文量
29
期刊介绍: Cochlear Implants International was founded as an interdisciplinary, peer-reviewed journal in response to the growing number of publications in the field of cochlear implants. It was designed to meet a need to include scientific contributions from all the disciplines that are represented in cochlear implant teams: audiology, medicine and surgery, speech therapy and speech pathology, psychology, hearing therapy, radiology, pathology, engineering and acoustics, teaching, and communication. The aim was to found a truly interdisciplinary journal, representing the full breadth of the field of cochlear implantation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信