Shonit Punwani, Peder E. Z. Larson, Christoffer Laustsen, Jan VanderMeulen, Jan Henrik Ardenkjær-Larsen, Adam W. Autry, James A. Bankson, Jenna Bernard, Robert Bok, Lotte Bonde Bertelsen, Jenny Che, Albert P. Chen, Rafat Chowdhury, Arnaud Comment, Charles H. Cunningham, Duy Dang, Ferdia A. Gallagher, Adam Gaunt, Yangcan Gong, Jeremy W. Gordon, Ashley Grimmer, James Grist, Esben Søvsø Szocska Hansen, Mathilde Hauge Lerche, Richard L. Hesketh, Jan-Bernd Hoevener, Ching-Yi Hsieh, Kayvan R. Keshari, Sebastian Kozerke, Titus Lanz, Dirk Mayer, Mary McLean, Jae Mo Park, Jim Slater, Damian Tyler, Jean-Luc Vanderheyden, Cornelius von Morze, Fulvio Zaccagna, Vlad Zaha, Duan Xu, Daniel Vigneron, The HP 13C MRI Consensus Group
{"title":"超极化[1-13C]丙酮酸MRI多中心人体研究的共识建议。","authors":"Shonit Punwani, Peder E. Z. Larson, Christoffer Laustsen, Jan VanderMeulen, Jan Henrik Ardenkjær-Larsen, Adam W. Autry, James A. Bankson, Jenna Bernard, Robert Bok, Lotte Bonde Bertelsen, Jenny Che, Albert P. Chen, Rafat Chowdhury, Arnaud Comment, Charles H. Cunningham, Duy Dang, Ferdia A. Gallagher, Adam Gaunt, Yangcan Gong, Jeremy W. Gordon, Ashley Grimmer, James Grist, Esben Søvsø Szocska Hansen, Mathilde Hauge Lerche, Richard L. Hesketh, Jan-Bernd Hoevener, Ching-Yi Hsieh, Kayvan R. Keshari, Sebastian Kozerke, Titus Lanz, Dirk Mayer, Mary McLean, Jae Mo Park, Jim Slater, Damian Tyler, Jean-Luc Vanderheyden, Cornelius von Morze, Fulvio Zaccagna, Vlad Zaha, Duan Xu, Daniel Vigneron, The HP 13C MRI Consensus Group","doi":"10.1002/mrm.30570","DOIUrl":null,"url":null,"abstract":"<p>MRI of hyperpolarized (HP) [1-<sup>13</sup>C]pyruvate allows in vivo assessment of metabolism and has translated into human studies across diseases at 15 centers worldwide. To determine consensus on best practice for multi-center studies for development of clinical applications. This paper presents the results of a two-round formal consensus building exercise carried out by experts with HP [1-<sup>13</sup>C]pyruvate human study experience. Twenty-nine participants from 13 sites brought together expertise in pharmacy methods, MR physics, translational imaging, and data analysis with the goal of providing recommendations and best practice statements on conduct of multi-center human studies of HP [1-<sup>13</sup>C]pyruvate MRI. Overall, the group reached consensus on approximately two-thirds of 246 statements in the questionnaire, covering HP <sup>13</sup>C-pyruvate preparation; MRI system setup, calibration, and phantoms; acquisition and reconstruction; and data analysis and quantification. Consensus was present across categories. Examples include: (i) Different HP pyruvate preparation methods could be used in human studies, but the same release criteria have to be followed; (ii) site qualification and quality assurance must be performed with phantoms and the same field strength must be used, but the rest of the system setup and calibration methods could be determined by individual sites; (iii) the same pulse sequence and reconstruction methods were preferable, but the exact choice should be governed by the anatomical target; (iv) normalized metabolite area-under-curve values and metabolite area under curve were the preferred metabolism metrics. The consensus proces revealed that HP[1-<sup>13</sup>C] pyruvate MRI as a technology has progressed sufficiently to plan multi-center studies. The work confirmed areas of consensus for multi-center study conduct and identified where further research is required to ascertain best practice.</p>","PeriodicalId":18065,"journal":{"name":"Magnetic Resonance in Medicine","volume":"94 4","pages":"1386-1400"},"PeriodicalIF":3.0000,"publicationDate":"2025-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12236423/pdf/","citationCount":"0","resultStr":"{\"title\":\"Consensus recommendations for hyperpolarized [1-13C]pyruvate MRI multi-center human studies\",\"authors\":\"Shonit Punwani, Peder E. Z. Larson, Christoffer Laustsen, Jan VanderMeulen, Jan Henrik Ardenkjær-Larsen, Adam W. Autry, James A. Bankson, Jenna Bernard, Robert Bok, Lotte Bonde Bertelsen, Jenny Che, Albert P. Chen, Rafat Chowdhury, Arnaud Comment, Charles H. Cunningham, Duy Dang, Ferdia A. Gallagher, Adam Gaunt, Yangcan Gong, Jeremy W. Gordon, Ashley Grimmer, James Grist, Esben Søvsø Szocska Hansen, Mathilde Hauge Lerche, Richard L. Hesketh, Jan-Bernd Hoevener, Ching-Yi Hsieh, Kayvan R. Keshari, Sebastian Kozerke, Titus Lanz, Dirk Mayer, Mary McLean, Jae Mo Park, Jim Slater, Damian Tyler, Jean-Luc Vanderheyden, Cornelius von Morze, Fulvio Zaccagna, Vlad Zaha, Duan Xu, Daniel Vigneron, The HP 13C MRI Consensus Group\",\"doi\":\"10.1002/mrm.30570\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>MRI of hyperpolarized (HP) [1-<sup>13</sup>C]pyruvate allows in vivo assessment of metabolism and has translated into human studies across diseases at 15 centers worldwide. To determine consensus on best practice for multi-center studies for development of clinical applications. This paper presents the results of a two-round formal consensus building exercise carried out by experts with HP [1-<sup>13</sup>C]pyruvate human study experience. Twenty-nine participants from 13 sites brought together expertise in pharmacy methods, MR physics, translational imaging, and data analysis with the goal of providing recommendations and best practice statements on conduct of multi-center human studies of HP [1-<sup>13</sup>C]pyruvate MRI. Overall, the group reached consensus on approximately two-thirds of 246 statements in the questionnaire, covering HP <sup>13</sup>C-pyruvate preparation; MRI system setup, calibration, and phantoms; acquisition and reconstruction; and data analysis and quantification. Consensus was present across categories. Examples include: (i) Different HP pyruvate preparation methods could be used in human studies, but the same release criteria have to be followed; (ii) site qualification and quality assurance must be performed with phantoms and the same field strength must be used, but the rest of the system setup and calibration methods could be determined by individual sites; (iii) the same pulse sequence and reconstruction methods were preferable, but the exact choice should be governed by the anatomical target; (iv) normalized metabolite area-under-curve values and metabolite area under curve were the preferred metabolism metrics. The consensus proces revealed that HP[1-<sup>13</sup>C] pyruvate MRI as a technology has progressed sufficiently to plan multi-center studies. The work confirmed areas of consensus for multi-center study conduct and identified where further research is required to ascertain best practice.</p>\",\"PeriodicalId\":18065,\"journal\":{\"name\":\"Magnetic Resonance in Medicine\",\"volume\":\"94 4\",\"pages\":\"1386-1400\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-06-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12236423/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic Resonance in Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/mrm.30570\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medicine","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/mrm.30570","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Consensus recommendations for hyperpolarized [1-13C]pyruvate MRI multi-center human studies
MRI of hyperpolarized (HP) [1-13C]pyruvate allows in vivo assessment of metabolism and has translated into human studies across diseases at 15 centers worldwide. To determine consensus on best practice for multi-center studies for development of clinical applications. This paper presents the results of a two-round formal consensus building exercise carried out by experts with HP [1-13C]pyruvate human study experience. Twenty-nine participants from 13 sites brought together expertise in pharmacy methods, MR physics, translational imaging, and data analysis with the goal of providing recommendations and best practice statements on conduct of multi-center human studies of HP [1-13C]pyruvate MRI. Overall, the group reached consensus on approximately two-thirds of 246 statements in the questionnaire, covering HP 13C-pyruvate preparation; MRI system setup, calibration, and phantoms; acquisition and reconstruction; and data analysis and quantification. Consensus was present across categories. Examples include: (i) Different HP pyruvate preparation methods could be used in human studies, but the same release criteria have to be followed; (ii) site qualification and quality assurance must be performed with phantoms and the same field strength must be used, but the rest of the system setup and calibration methods could be determined by individual sites; (iii) the same pulse sequence and reconstruction methods were preferable, but the exact choice should be governed by the anatomical target; (iv) normalized metabolite area-under-curve values and metabolite area under curve were the preferred metabolism metrics. The consensus proces revealed that HP[1-13C] pyruvate MRI as a technology has progressed sufficiently to plan multi-center studies. The work confirmed areas of consensus for multi-center study conduct and identified where further research is required to ascertain best practice.
期刊介绍:
Magnetic Resonance in Medicine (Magn Reson Med) is an international journal devoted to the publication of original investigations concerned with all aspects of the development and use of nuclear magnetic resonance and electron paramagnetic resonance techniques for medical applications. Reports of original investigations in the areas of mathematics, computing, engineering, physics, biophysics, chemistry, biochemistry, and physiology directly relevant to magnetic resonance will be accepted, as well as methodology-oriented clinical studies.