Hajime Akashi, Tomohiro Kobayashi, Toshio Yamanaka, Kana Sato
{"title":"自然通风控制建筑屋面外风速监测点","authors":"Hajime Akashi, Tomohiro Kobayashi, Toshio Yamanaka, Kana Sato","doi":"10.1002/2475-8876.70032","DOIUrl":null,"url":null,"abstract":"<p>In order to measure external approaching wind velocity and direction for controlling natural ventilation (NV), anemometers are often installed at the roof top of mid- to high-rise buildings. However, due to the complex flow field around roof top caused by separation flow, the accuracy of the measurement is not well-known. The final goal of this research is to propose an advanced method for controlling NV operation. By conducting PIV and CFD, the results of the accuracy of estimation of external wind direction and velocity at measuring points based on the data regarding horizontal distribution are shown in this paper.</p>","PeriodicalId":42793,"journal":{"name":"Japan Architectural Review","volume":"8 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2025-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/2475-8876.70032","citationCount":"0","resultStr":"{\"title\":\"Monitoring Point of External Wind Velocity Around Building Roof Top for Natural Ventilation Control\",\"authors\":\"Hajime Akashi, Tomohiro Kobayashi, Toshio Yamanaka, Kana Sato\",\"doi\":\"10.1002/2475-8876.70032\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>In order to measure external approaching wind velocity and direction for controlling natural ventilation (NV), anemometers are often installed at the roof top of mid- to high-rise buildings. However, due to the complex flow field around roof top caused by separation flow, the accuracy of the measurement is not well-known. The final goal of this research is to propose an advanced method for controlling NV operation. By conducting PIV and CFD, the results of the accuracy of estimation of external wind direction and velocity at measuring points based on the data regarding horizontal distribution are shown in this paper.</p>\",\"PeriodicalId\":42793,\"journal\":{\"name\":\"Japan Architectural Review\",\"volume\":\"8 1\",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2025-06-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/2475-8876.70032\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Japan Architectural Review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/2475-8876.70032\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"0\",\"JCRName\":\"ARCHITECTURE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japan Architectural Review","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/2475-8876.70032","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"ARCHITECTURE","Score":null,"Total":0}
Monitoring Point of External Wind Velocity Around Building Roof Top for Natural Ventilation Control
In order to measure external approaching wind velocity and direction for controlling natural ventilation (NV), anemometers are often installed at the roof top of mid- to high-rise buildings. However, due to the complex flow field around roof top caused by separation flow, the accuracy of the measurement is not well-known. The final goal of this research is to propose an advanced method for controlling NV operation. By conducting PIV and CFD, the results of the accuracy of estimation of external wind direction and velocity at measuring points based on the data regarding horizontal distribution are shown in this paper.