STARGUS:一种新型扫描源生物计与b超诊断致密性白内障的比较研究。

Héloïse Torres-Villaros, Maté Streho, Didier Hoa, Audrey Giocanti-Aurégan
{"title":"STARGUS:一种新型扫描源生物计与b超诊断致密性白内障的比较研究。","authors":"Héloïse Torres-Villaros, Maté Streho, Didier Hoa, Audrey Giocanti-Aurégan","doi":"10.1007/s00417-025-06863-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to compare a new swept-source biometer to the gold standard B-mode ultrasound biometer for measuring the axial length (AL) when standard optical biometers failed due to cataract density.</p><p><strong>Methods: </strong>Patients with advanced cataracts whose AL could not be measured using optical biometers available in our clinics, including the Lenstar LS-900 and IOLMaster 500 and 700, were included. The AL, anterior chamber depth (ACD), and lens thickness (LT) were measured using a new swept-source biometer (SSB) (Argos<sup>®</sup>, Alcon) and B-mode ultrasound. The Enhanced Retinal Visualization (ERV) mode of the new SSB was used when the standard mode did not provide reliable AL measurements.</p><p><strong>Results: </strong>AL measurements failed in 183 eyes due to cataract density using available biometers. The new SSB allowed successfully measuring the AL in 89.6% of cases, and the ERV mode was needed in 15.8% of eyes. The ALs measured with the new SSB and B-mode ultrasound were comparable, with an excellent intraclass correlation coefficient (ICC) of 0.99. No significant differences in ACD measurements were observed between new SSB and ultrasound or conventional biometers, with ICC of 0.81 and 0.87, respectively. However, the LT tended to be thinner with the new SSB compared to ultrasound, suggesting a potential source of error, but no significant difference was observed with conventional biometers (ICC of 0.88).</p><p><strong>Conclusions: </strong>The new SSB Argos<sup>®</sup>, in particular when the ERV mode is used, could be a reliable alternative to B-mode ultrasound for measuring AL in eyes with dense cataracts. It is as effective as ultrasound in measuring the AL, and it could help to improve cataract surgery planning and outcomes.</p>","PeriodicalId":520634,"journal":{"name":"Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"STARGUS: a comparative study of a new swept-source biometer and B-mode ultrasound in dense cataracts.\",\"authors\":\"Héloïse Torres-Villaros, Maté Streho, Didier Hoa, Audrey Giocanti-Aurégan\",\"doi\":\"10.1007/s00417-025-06863-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study aimed to compare a new swept-source biometer to the gold standard B-mode ultrasound biometer for measuring the axial length (AL) when standard optical biometers failed due to cataract density.</p><p><strong>Methods: </strong>Patients with advanced cataracts whose AL could not be measured using optical biometers available in our clinics, including the Lenstar LS-900 and IOLMaster 500 and 700, were included. The AL, anterior chamber depth (ACD), and lens thickness (LT) were measured using a new swept-source biometer (SSB) (Argos<sup>®</sup>, Alcon) and B-mode ultrasound. The Enhanced Retinal Visualization (ERV) mode of the new SSB was used when the standard mode did not provide reliable AL measurements.</p><p><strong>Results: </strong>AL measurements failed in 183 eyes due to cataract density using available biometers. The new SSB allowed successfully measuring the AL in 89.6% of cases, and the ERV mode was needed in 15.8% of eyes. The ALs measured with the new SSB and B-mode ultrasound were comparable, with an excellent intraclass correlation coefficient (ICC) of 0.99. No significant differences in ACD measurements were observed between new SSB and ultrasound or conventional biometers, with ICC of 0.81 and 0.87, respectively. However, the LT tended to be thinner with the new SSB compared to ultrasound, suggesting a potential source of error, but no significant difference was observed with conventional biometers (ICC of 0.88).</p><p><strong>Conclusions: </strong>The new SSB Argos<sup>®</sup>, in particular when the ERV mode is used, could be a reliable alternative to B-mode ultrasound for measuring AL in eyes with dense cataracts. It is as effective as ultrasound in measuring the AL, and it could help to improve cataract surgery planning and outcomes.</p>\",\"PeriodicalId\":520634,\"journal\":{\"name\":\"Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s00417-025-06863-0\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s00417-025-06863-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在比较一种新的扫描源生物计与金标准b超生物计在标准光学生物计因白内障密度而失效时测量轴长(AL)的效果。方法:纳入我院现有光学生物计(包括Lenstar LS-900和IOLMaster 500和700)无法测量AL的晚期白内障患者。采用新型扫描源生物计(SSB) (Argos®,Alcon)和b超测量AL、前房深度(ACD)和晶状体厚度(LT)。当标准模式不能提供可靠的AL测量时,采用新SSB的增强视网膜可视化(Enhanced Retinal Visualization, ERV)模式。结果:使用现有生物计对183只眼进行白内障密度测量失败。新的SSB可以在89.6%的病例中成功测量AL, 15.8%的眼睛需要ERV模式。新型SSB与b超测量的ALs具有可比性,类内相关系数(ICC)为0.99。新SSB与超声或传统生物计的ACD测量值无显著差异,ICC分别为0.81和0.87。然而,与超声相比,新SSB的LT倾向于更薄,这可能是误差的潜在来源,但与传统生物计没有显著差异(ICC为0.88)。结论:新的SSB Argos®,特别是当使用ERV模式时,可能是b超测量致密性白内障眼睛AL的可靠替代方案。在测量人工晶状体方面,它和超声波一样有效,它可以帮助改善白内障手术的计划和结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
STARGUS: a comparative study of a new swept-source biometer and B-mode ultrasound in dense cataracts.

Purpose: This study aimed to compare a new swept-source biometer to the gold standard B-mode ultrasound biometer for measuring the axial length (AL) when standard optical biometers failed due to cataract density.

Methods: Patients with advanced cataracts whose AL could not be measured using optical biometers available in our clinics, including the Lenstar LS-900 and IOLMaster 500 and 700, were included. The AL, anterior chamber depth (ACD), and lens thickness (LT) were measured using a new swept-source biometer (SSB) (Argos®, Alcon) and B-mode ultrasound. The Enhanced Retinal Visualization (ERV) mode of the new SSB was used when the standard mode did not provide reliable AL measurements.

Results: AL measurements failed in 183 eyes due to cataract density using available biometers. The new SSB allowed successfully measuring the AL in 89.6% of cases, and the ERV mode was needed in 15.8% of eyes. The ALs measured with the new SSB and B-mode ultrasound were comparable, with an excellent intraclass correlation coefficient (ICC) of 0.99. No significant differences in ACD measurements were observed between new SSB and ultrasound or conventional biometers, with ICC of 0.81 and 0.87, respectively. However, the LT tended to be thinner with the new SSB compared to ultrasound, suggesting a potential source of error, but no significant difference was observed with conventional biometers (ICC of 0.88).

Conclusions: The new SSB Argos®, in particular when the ERV mode is used, could be a reliable alternative to B-mode ultrasound for measuring AL in eyes with dense cataracts. It is as effective as ultrasound in measuring the AL, and it could help to improve cataract surgery planning and outcomes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信