用于心脏健康监测的光电可穿戴传感器。

IF 3 3区 医学 Q2 BIOCHEMICAL RESEARCH METHODS
Journal of Biomedical Optics Pub Date : 2025-06-01 Epub Date: 2025-06-11 DOI:10.1117/1.JBO.30.6.067002
Michal Katan, Rui M R Pinto, Shiran Arol-Wiegand, Bar Atuar, Alon Tzroya, Hamootal Duadi, K B Vinayakumar, Dror Fixler
{"title":"用于心脏健康监测的光电可穿戴传感器。","authors":"Michal Katan, Rui M R Pinto, Shiran Arol-Wiegand, Bar Atuar, Alon Tzroya, Hamootal Duadi, K B Vinayakumar, Dror Fixler","doi":"10.1117/1.JBO.30.6.067002","DOIUrl":null,"url":null,"abstract":"<p><strong>Significance: </strong>Integrating multiple biosensors improves the sensitivity and precision of physiological measurements in healthcare monitoring. By combining sensors that target different physiological parameters, a more comprehensive assessment of a subject's health can be achieved.</p><p><strong>Aim: </strong>We evaluate the performance of two biosensors for extracting cardiac parameters: a textile-based strain sensor for measuring respiratory rate and an optical sensor for measuring heart rate, <math> <mrow> <msub><mrow><mi>SpO</mi></mrow> <mrow><mn>2</mn></mrow> </msub> </mrow> </math> , and respiratory rate. The objective is to determine optimal placement conditions for each sensor and assess their feasibility for integration into a single wearable system.</p><p><strong>Approach: </strong>Two experimental setups were tested. In the first, the strain sensor was placed on the subject's shirt, while the optical sensor was positioned on the external wrist. In the second, both sensors were placed on the chest, under the shirt. The accuracy and performance of each sensor were analyzed in both configurations.</p><p><strong>Results: </strong>The optical sensor demonstrated improved accuracy when placed on the chest compared to the wrist, whereas the strain sensor provided similar results for both configurations.</p><p><strong>Conclusions: </strong>We demonstrate that sensor placement significantly affects measurement quality, emphasizing the importance of optimizing placement when integrating multiple biosensors. Future work will focus on developing a unified wearable system that leverages the strengths of both sensors for comprehensive physiological monitoring.</p>","PeriodicalId":15264,"journal":{"name":"Journal of Biomedical Optics","volume":"30 6","pages":"067002"},"PeriodicalIF":3.0000,"publicationDate":"2025-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12152588/pdf/","citationCount":"0","resultStr":"{\"title\":\"Combined optical-electromechanical wearable sensors for cardiac health monitoring.\",\"authors\":\"Michal Katan, Rui M R Pinto, Shiran Arol-Wiegand, Bar Atuar, Alon Tzroya, Hamootal Duadi, K B Vinayakumar, Dror Fixler\",\"doi\":\"10.1117/1.JBO.30.6.067002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Significance: </strong>Integrating multiple biosensors improves the sensitivity and precision of physiological measurements in healthcare monitoring. By combining sensors that target different physiological parameters, a more comprehensive assessment of a subject's health can be achieved.</p><p><strong>Aim: </strong>We evaluate the performance of two biosensors for extracting cardiac parameters: a textile-based strain sensor for measuring respiratory rate and an optical sensor for measuring heart rate, <math> <mrow> <msub><mrow><mi>SpO</mi></mrow> <mrow><mn>2</mn></mrow> </msub> </mrow> </math> , and respiratory rate. The objective is to determine optimal placement conditions for each sensor and assess their feasibility for integration into a single wearable system.</p><p><strong>Approach: </strong>Two experimental setups were tested. In the first, the strain sensor was placed on the subject's shirt, while the optical sensor was positioned on the external wrist. In the second, both sensors were placed on the chest, under the shirt. The accuracy and performance of each sensor were analyzed in both configurations.</p><p><strong>Results: </strong>The optical sensor demonstrated improved accuracy when placed on the chest compared to the wrist, whereas the strain sensor provided similar results for both configurations.</p><p><strong>Conclusions: </strong>We demonstrate that sensor placement significantly affects measurement quality, emphasizing the importance of optimizing placement when integrating multiple biosensors. Future work will focus on developing a unified wearable system that leverages the strengths of both sensors for comprehensive physiological monitoring.</p>\",\"PeriodicalId\":15264,\"journal\":{\"name\":\"Journal of Biomedical Optics\",\"volume\":\"30 6\",\"pages\":\"067002\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12152588/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biomedical Optics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1117/1.JBO.30.6.067002\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/6/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomedical Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.JBO.30.6.067002","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/6/11 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

意义:集成多个生物传感器可提高医疗监测中生理测量的灵敏度和精度。通过结合针对不同生理参数的传感器,可以实现对受试者健康状况的更全面评估。目的:我们评估了两种用于提取心脏参数的生物传感器的性能:用于测量呼吸速率的基于纺织品的应变传感器和用于测量心率,SpO 2和呼吸速率的光学传感器。目标是确定每个传感器的最佳放置条件,并评估其集成到单个可穿戴系统中的可行性。方法:对两种实验设置进行了测试。在第一个实验中,应变传感器被放置在受试者的衬衫上,而光学传感器被放置在外部手腕上。在第二组实验中,两个传感器都被放置在胸部衬衫下面。分析了两种配置下各传感器的精度和性能。结果:与手腕相比,光学传感器在放置在胸部时显示出更高的准确性,而应变传感器在两种配置下提供了相似的结果。结论:我们证明了传感器的放置显著影响测量质量,强调了在集成多个生物传感器时优化放置的重要性。未来的工作将集中于开发一种统一的可穿戴系统,利用这两种传感器的优势进行全面的生理监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Combined optical-electromechanical wearable sensors for cardiac health monitoring.

Significance: Integrating multiple biosensors improves the sensitivity and precision of physiological measurements in healthcare monitoring. By combining sensors that target different physiological parameters, a more comprehensive assessment of a subject's health can be achieved.

Aim: We evaluate the performance of two biosensors for extracting cardiac parameters: a textile-based strain sensor for measuring respiratory rate and an optical sensor for measuring heart rate, SpO 2 , and respiratory rate. The objective is to determine optimal placement conditions for each sensor and assess their feasibility for integration into a single wearable system.

Approach: Two experimental setups were tested. In the first, the strain sensor was placed on the subject's shirt, while the optical sensor was positioned on the external wrist. In the second, both sensors were placed on the chest, under the shirt. The accuracy and performance of each sensor were analyzed in both configurations.

Results: The optical sensor demonstrated improved accuracy when placed on the chest compared to the wrist, whereas the strain sensor provided similar results for both configurations.

Conclusions: We demonstrate that sensor placement significantly affects measurement quality, emphasizing the importance of optimizing placement when integrating multiple biosensors. Future work will focus on developing a unified wearable system that leverages the strengths of both sensors for comprehensive physiological monitoring.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.40
自引率
5.70%
发文量
263
审稿时长
2 months
期刊介绍: The Journal of Biomedical Optics publishes peer-reviewed papers on the use of modern optical technology for improved health care and biomedical research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信