Junhong Yan, Xuemin Zhou, Qi Zheng, Kun Wang, Yanbing Gao, Feifei Liu, Lei Pan
{"title":"基于超声放射组学和双模超声弹性成像的良恶性甲状腺结节分类机器学习模型。","authors":"Junhong Yan, Xuemin Zhou, Qi Zheng, Kun Wang, Yanbing Gao, Feifei Liu, Lei Pan","doi":"10.1002/jcu.24104","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The present study aims to construct a random forest (RF) model based on ultrasound radiomics and elastography, offering a new approach for the differentiation of thyroid nodules (TNs).</p><p><strong>Methods: </strong>We retrospectively analyzed 152 TNs from 127 patients and developed four machine learning models. The examination was performed using the Resona 9Pro equipped with a 15-4 MHz linear array probe. The region of interest (ROI) was delineated with 3D Slicer. Using the RF algorithm, four models were developed based on sound touch elastography (STE) parameters, strain elastography (SE) parameters, and the selected radiomic features: the STE model, SE model, radiomics model, and the combined model. Decision Curve Analysis (DCA) is employed to assess the clinical benefit of each model. The DeLong test is used to determine whether the area under the curves (AUC) values of different models are statistically significant.</p><p><strong>Results: </strong>A total of 1396 radiomic features were extracted using the Pyradiomics package. After screening, a total of 7 radiomic features were ultimately included in the construction of the model. In STE, SE, radiomics model, and combined model, the AUCs are 0.699 (95% CI: 0.570-0.828), 0.812 (95% CI: 0.683-0.941), 0.851 (95% CI: 0.739-0.964) and 0.911 (95% CI: 0.806-1.000), respectively. In these models, the combined model and the radiomics model exhibited outstanding performance.</p><p><strong>Conclusions: </strong>The combined model, integrating elastography and radiomics, demonstrates superior predictive accuracy compared to single models, offering a promising approach for the diagnosis of TNs.</p>","PeriodicalId":15386,"journal":{"name":"Journal of Clinical Ultrasound","volume":" ","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2025-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ultrasound Radiomics and Dual-Mode Ultrasonic Elastography Based Machine Learning Model for the Classification of Benign and Malignant Thyroid Nodules.\",\"authors\":\"Junhong Yan, Xuemin Zhou, Qi Zheng, Kun Wang, Yanbing Gao, Feifei Liu, Lei Pan\",\"doi\":\"10.1002/jcu.24104\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The present study aims to construct a random forest (RF) model based on ultrasound radiomics and elastography, offering a new approach for the differentiation of thyroid nodules (TNs).</p><p><strong>Methods: </strong>We retrospectively analyzed 152 TNs from 127 patients and developed four machine learning models. The examination was performed using the Resona 9Pro equipped with a 15-4 MHz linear array probe. The region of interest (ROI) was delineated with 3D Slicer. Using the RF algorithm, four models were developed based on sound touch elastography (STE) parameters, strain elastography (SE) parameters, and the selected radiomic features: the STE model, SE model, radiomics model, and the combined model. Decision Curve Analysis (DCA) is employed to assess the clinical benefit of each model. The DeLong test is used to determine whether the area under the curves (AUC) values of different models are statistically significant.</p><p><strong>Results: </strong>A total of 1396 radiomic features were extracted using the Pyradiomics package. After screening, a total of 7 radiomic features were ultimately included in the construction of the model. In STE, SE, radiomics model, and combined model, the AUCs are 0.699 (95% CI: 0.570-0.828), 0.812 (95% CI: 0.683-0.941), 0.851 (95% CI: 0.739-0.964) and 0.911 (95% CI: 0.806-1.000), respectively. In these models, the combined model and the radiomics model exhibited outstanding performance.</p><p><strong>Conclusions: </strong>The combined model, integrating elastography and radiomics, demonstrates superior predictive accuracy compared to single models, offering a promising approach for the diagnosis of TNs.</p>\",\"PeriodicalId\":15386,\"journal\":{\"name\":\"Journal of Clinical Ultrasound\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2025-06-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Ultrasound\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/jcu.24104\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Ultrasound","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jcu.24104","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ACOUSTICS","Score":null,"Total":0}
Ultrasound Radiomics and Dual-Mode Ultrasonic Elastography Based Machine Learning Model for the Classification of Benign and Malignant Thyroid Nodules.
Introduction: The present study aims to construct a random forest (RF) model based on ultrasound radiomics and elastography, offering a new approach for the differentiation of thyroid nodules (TNs).
Methods: We retrospectively analyzed 152 TNs from 127 patients and developed four machine learning models. The examination was performed using the Resona 9Pro equipped with a 15-4 MHz linear array probe. The region of interest (ROI) was delineated with 3D Slicer. Using the RF algorithm, four models were developed based on sound touch elastography (STE) parameters, strain elastography (SE) parameters, and the selected radiomic features: the STE model, SE model, radiomics model, and the combined model. Decision Curve Analysis (DCA) is employed to assess the clinical benefit of each model. The DeLong test is used to determine whether the area under the curves (AUC) values of different models are statistically significant.
Results: A total of 1396 radiomic features were extracted using the Pyradiomics package. After screening, a total of 7 radiomic features were ultimately included in the construction of the model. In STE, SE, radiomics model, and combined model, the AUCs are 0.699 (95% CI: 0.570-0.828), 0.812 (95% CI: 0.683-0.941), 0.851 (95% CI: 0.739-0.964) and 0.911 (95% CI: 0.806-1.000), respectively. In these models, the combined model and the radiomics model exhibited outstanding performance.
Conclusions: The combined model, integrating elastography and radiomics, demonstrates superior predictive accuracy compared to single models, offering a promising approach for the diagnosis of TNs.
期刊介绍:
The Journal of Clinical Ultrasound (JCU) is an international journal dedicated to the worldwide dissemination of scientific information on diagnostic and therapeutic applications of medical sonography.
The scope of the journal includes--but is not limited to--the following areas: sonography of the gastrointestinal tract, genitourinary tract, vascular system, nervous system, head and neck, chest, breast, musculoskeletal system, and other superficial structures; Doppler applications; obstetric and pediatric applications; and interventional sonography. Studies comparing sonography with other imaging modalities are encouraged, as are studies evaluating the economic impact of sonography. Also within the journal''s scope are innovations and improvements in instrumentation and examination techniques and the use of contrast agents.
JCU publishes original research articles, case reports, pictorial essays, technical notes, and letters to the editor. The journal is also dedicated to being an educational resource for its readers, through the publication of review articles and various scientific contributions from members of the editorial board and other world-renowned experts in sonography.