Valerie Vandenbempt, Michael Roach, Monika Mohenska, Kellie Wise, Taopeng Wang, Kate Harvey, Kirk Jensen, Alexander Swarbrick, Jose M Polo, Esteban N Gurzov, Luciano G Martelotto
{"title":"来自Illumina和MGI Tech测序平台的单细胞转录组谱验证。","authors":"Valerie Vandenbempt, Michael Roach, Monika Mohenska, Kellie Wise, Taopeng Wang, Kate Harvey, Kirk Jensen, Alexander Swarbrick, Jose M Polo, Esteban N Gurzov, Luciano G Martelotto","doi":"10.1002/1873-3468.70087","DOIUrl":null,"url":null,"abstract":"<p><p>While Illumina is currently used for high-throughput short-read sequencing, MGI Tech have developed a similar sequencing method at a lower cost. Comparisons of the two platforms revealed that their accuracy, sensitivity, and reproducibility are very similar, but the impact of each on biological insights, particularly in heterogeneous samples, remains unknown. Illumina and MGI Tech were used to generate single-cell RNA-seq libraries from three human cancer samples. While unique platform-specific cells arise after additional cell quality controls, the chosen sequencing platform did not affect either clustering or gene expression analyses. In conclusion, MGI Tech delivers transcriptomic profiles similar to those of Illumina and can be confidently used for high-throughput applications.</p>","PeriodicalId":12142,"journal":{"name":"FEBS Letters","volume":" ","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2025-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of single-cell transcriptomic profiles from Illumina and MGI Tech sequencing platforms.\",\"authors\":\"Valerie Vandenbempt, Michael Roach, Monika Mohenska, Kellie Wise, Taopeng Wang, Kate Harvey, Kirk Jensen, Alexander Swarbrick, Jose M Polo, Esteban N Gurzov, Luciano G Martelotto\",\"doi\":\"10.1002/1873-3468.70087\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>While Illumina is currently used for high-throughput short-read sequencing, MGI Tech have developed a similar sequencing method at a lower cost. Comparisons of the two platforms revealed that their accuracy, sensitivity, and reproducibility are very similar, but the impact of each on biological insights, particularly in heterogeneous samples, remains unknown. Illumina and MGI Tech were used to generate single-cell RNA-seq libraries from three human cancer samples. While unique platform-specific cells arise after additional cell quality controls, the chosen sequencing platform did not affect either clustering or gene expression analyses. In conclusion, MGI Tech delivers transcriptomic profiles similar to those of Illumina and can be confidently used for high-throughput applications.</p>\",\"PeriodicalId\":12142,\"journal\":{\"name\":\"FEBS Letters\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2025-06-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"FEBS Letters\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.1002/1873-3468.70087\",\"RegionNum\":4,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Biochemistry, Genetics and Molecular Biology\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"FEBS Letters","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1002/1873-3468.70087","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
Validation of single-cell transcriptomic profiles from Illumina and MGI Tech sequencing platforms.
While Illumina is currently used for high-throughput short-read sequencing, MGI Tech have developed a similar sequencing method at a lower cost. Comparisons of the two platforms revealed that their accuracy, sensitivity, and reproducibility are very similar, but the impact of each on biological insights, particularly in heterogeneous samples, remains unknown. Illumina and MGI Tech were used to generate single-cell RNA-seq libraries from three human cancer samples. While unique platform-specific cells arise after additional cell quality controls, the chosen sequencing platform did not affect either clustering or gene expression analyses. In conclusion, MGI Tech delivers transcriptomic profiles similar to those of Illumina and can be confidently used for high-throughput applications.
期刊介绍:
FEBS Letters is one of the world''s leading journals in molecular biology and is renowned both for its quality of content and speed of production. Bringing together the most important developments in the molecular biosciences, FEBS Letters provides an international forum for Minireviews, Research Letters and Hypotheses that merit urgent publication.