基质体系对后牙体填充树脂复合材料修复体近端接触质量影响的体外研究。

IF 3.1 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Laryssa Silva da Cunha, Karoline Guará Brusaca Almeida Cavalcanti, Thiago Silva Peres, Andres Felipe Millan Cardenas, Gisele Rodrigues da Silva, Carlos José Soares
{"title":"基质体系对后牙体填充树脂复合材料修复体近端接触质量影响的体外研究。","authors":"Laryssa Silva da Cunha, Karoline Guará Brusaca Almeida Cavalcanti, Thiago Silva Peres, Andres Felipe Millan Cardenas, Gisele Rodrigues da Silva, Carlos José Soares","doi":"10.1007/s00784-025-06402-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Evaluate the effect of matrix systems on the proximal contact force (N) between molars and premolars in two class-II bulk-fill resin composite restorations.</p><p><strong>Methods: </strong>The Typodont model of the first molar, with adjacent molar and premolar simulating the periodontal ligament was used to analyze proximal contact in two class-II restorations (n = 10) made with OPUS Bulk Fill resin composite. Four types of matrices were tested: two sectional (Palodent V3 and Unimatrix R) and two circumferential (SuperMat and universal metal matrix. Intact tooth was used as the control group). The specimens were radiographed and proximal contact force (N) were measured in a microtensile testing machine (Odeme). Data were analyzed using two-way ANOVA followed by the Tukey and Dunnet tests (α = 0.05).</p><p><strong>Results: </strong>The contact force on the premolar was lower than that on the molar (P < 0.001) irrespective of the matrix system. The sectional matrices produced similar proximal contact forces as the intact tooth (P = 0.109) and higher than the circumferential matrices (P < 0.001), irrespective of the tooth-type contact. The radiographic analysis showed predominantly perfect proximal contact in the sectional matrix specimens.</p><p><strong>Conclusions: </strong>The contour and proximal contact forces were influenced by the matrix systems and tooth contact location. The sectional matrices had better proximal contact force than the circumferential matrices.</p><p><strong>Clinical relevance: </strong>Compared with circumferential matrices, sectional matrices are more flexible and can be moved easily to the direction of the adjacent tooth to produce better proximal contact in class-II bulk-fill resin composite restorations.</p>","PeriodicalId":10461,"journal":{"name":"Clinical Oral Investigations","volume":"29 7","pages":"337"},"PeriodicalIF":3.1000,"publicationDate":"2025-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of matrix system on the quality of proximal contact in posterior bulk-fill resin composite restorations- an in vitro study.\",\"authors\":\"Laryssa Silva da Cunha, Karoline Guará Brusaca Almeida Cavalcanti, Thiago Silva Peres, Andres Felipe Millan Cardenas, Gisele Rodrigues da Silva, Carlos José Soares\",\"doi\":\"10.1007/s00784-025-06402-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Evaluate the effect of matrix systems on the proximal contact force (N) between molars and premolars in two class-II bulk-fill resin composite restorations.</p><p><strong>Methods: </strong>The Typodont model of the first molar, with adjacent molar and premolar simulating the periodontal ligament was used to analyze proximal contact in two class-II restorations (n = 10) made with OPUS Bulk Fill resin composite. Four types of matrices were tested: two sectional (Palodent V3 and Unimatrix R) and two circumferential (SuperMat and universal metal matrix. Intact tooth was used as the control group). The specimens were radiographed and proximal contact force (N) were measured in a microtensile testing machine (Odeme). Data were analyzed using two-way ANOVA followed by the Tukey and Dunnet tests (α = 0.05).</p><p><strong>Results: </strong>The contact force on the premolar was lower than that on the molar (P < 0.001) irrespective of the matrix system. The sectional matrices produced similar proximal contact forces as the intact tooth (P = 0.109) and higher than the circumferential matrices (P < 0.001), irrespective of the tooth-type contact. The radiographic analysis showed predominantly perfect proximal contact in the sectional matrix specimens.</p><p><strong>Conclusions: </strong>The contour and proximal contact forces were influenced by the matrix systems and tooth contact location. The sectional matrices had better proximal contact force than the circumferential matrices.</p><p><strong>Clinical relevance: </strong>Compared with circumferential matrices, sectional matrices are more flexible and can be moved easily to the direction of the adjacent tooth to produce better proximal contact in class-II bulk-fill resin composite restorations.</p>\",\"PeriodicalId\":10461,\"journal\":{\"name\":\"Clinical Oral Investigations\",\"volume\":\"29 7\",\"pages\":\"337\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2025-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Oral Investigations\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00784-025-06402-5\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Oral Investigations","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00784-025-06402-5","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价基质体系对两种ii类体填充树脂复合修复体中磨牙与前磨牙近端接触力(N)的影响。方法:采用第一磨牙的typdon模型,相邻磨牙和前磨牙模拟牙周韧带,对2个ii类修复体(n = 10)进行近端接触分析。测试了四种类型的矩阵:两种截面(Palodent V3和Unimatrix R)和两种圆周(SuperMat和通用金属矩阵)。以完好牙为对照组)。在微拉伸试验机(Odeme)上测量近端接触力(N)。数据分析采用双因素方差分析,然后采用Tukey和Dunnet检验(α = 0.05)。结果:前磨牙的接触力低于磨牙的接触力(P)。结论:基质系统和牙体接触位置影响牙体的近端接触力。截面型基质比周向型基质具有更好的近端接触力。临床意义:在ii类大块填充树脂复合修复体中,与周向基质相比,截面基质更灵活,易于向邻牙方向移动,产生更好的近端接触。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of matrix system on the quality of proximal contact in posterior bulk-fill resin composite restorations- an in vitro study.

Objective: Evaluate the effect of matrix systems on the proximal contact force (N) between molars and premolars in two class-II bulk-fill resin composite restorations.

Methods: The Typodont model of the first molar, with adjacent molar and premolar simulating the periodontal ligament was used to analyze proximal contact in two class-II restorations (n = 10) made with OPUS Bulk Fill resin composite. Four types of matrices were tested: two sectional (Palodent V3 and Unimatrix R) and two circumferential (SuperMat and universal metal matrix. Intact tooth was used as the control group). The specimens were radiographed and proximal contact force (N) were measured in a microtensile testing machine (Odeme). Data were analyzed using two-way ANOVA followed by the Tukey and Dunnet tests (α = 0.05).

Results: The contact force on the premolar was lower than that on the molar (P < 0.001) irrespective of the matrix system. The sectional matrices produced similar proximal contact forces as the intact tooth (P = 0.109) and higher than the circumferential matrices (P < 0.001), irrespective of the tooth-type contact. The radiographic analysis showed predominantly perfect proximal contact in the sectional matrix specimens.

Conclusions: The contour and proximal contact forces were influenced by the matrix systems and tooth contact location. The sectional matrices had better proximal contact force than the circumferential matrices.

Clinical relevance: Compared with circumferential matrices, sectional matrices are more flexible and can be moved easily to the direction of the adjacent tooth to produce better proximal contact in class-II bulk-fill resin composite restorations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical Oral Investigations
Clinical Oral Investigations 医学-牙科与口腔外科
CiteScore
6.30
自引率
5.90%
发文量
484
审稿时长
3 months
期刊介绍: The journal Clinical Oral Investigations is a multidisciplinary, international forum for publication of research from all fields of oral medicine. The journal publishes original scientific articles and invited reviews which provide up-to-date results of basic and clinical studies in oral and maxillofacial science and medicine. The aim is to clarify the relevance of new results to modern practice, for an international readership. Coverage includes maxillofacial and oral surgery, prosthetics and restorative dentistry, operative dentistry, endodontics, periodontology, orthodontics, dental materials science, clinical trials, epidemiology, pedodontics, oral implant, preventive dentistiry, oral pathology, oral basic sciences and more.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信