Dayun Tang, Peng Li, Shuo Qi, Qiong Wu, Ruili Yu, Mei Liu and Zhouping Wang
{"title":"基于全封闭微流控芯片盒的食品样品食源性病原体即时分析","authors":"Dayun Tang, Peng Li, Shuo Qi, Qiong Wu, Ruili Yu, Mei Liu and Zhouping Wang","doi":"10.1039/D4LC00819G","DOIUrl":null,"url":null,"abstract":"<p >Foodborne pathogens endanger public health and rapid, sensitive, and accurate detection of them is vital. Portable, highly integrated detection devices have great application prospects in the screening and analysis of foodborne pathogens. In this study, a fully automated detection device based on a fully enclosed microfluidic chip cartridge was successfully designed. This device integrates multiple functions, including nucleic acid extraction, reagent preparation, LAMP reaction, and signal detection. By simply adding a sample, it can simultaneously detect four types of foodborne pathogens, making it advantageous for the analysis of complex samples and improving detection accuracy. Additionally, freeze-dried reagents are integrated into the fully enclosed microfluidic chip cartridge, which allows the reagents to be transported and stored at room temperature, greatly reducing the cost of detection. It has been successfully applied in actual samples contaminated with multiple foodborne pathogens and has excellent stability. The entire detection process can be completed in 45 minutes, with a sensitivity of approximately 500 CFU mL<small><sup>−1</sup></small>. Therefore, the automated microfluidic device would be adequate for point-of-care testing (POCT) with high simplicity and high speed, providing an advanced genetic analysis microsystem for foodborne pathogen detection.</p>","PeriodicalId":85,"journal":{"name":"Lab on a Chip","volume":" 14","pages":" 3537-3548"},"PeriodicalIF":5.4000,"publicationDate":"2025-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Point-of-care analysis for foodborne pathogens in food samples based on a fully enclosed microfluidic chip cartridge\",\"authors\":\"Dayun Tang, Peng Li, Shuo Qi, Qiong Wu, Ruili Yu, Mei Liu and Zhouping Wang\",\"doi\":\"10.1039/D4LC00819G\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Foodborne pathogens endanger public health and rapid, sensitive, and accurate detection of them is vital. Portable, highly integrated detection devices have great application prospects in the screening and analysis of foodborne pathogens. In this study, a fully automated detection device based on a fully enclosed microfluidic chip cartridge was successfully designed. This device integrates multiple functions, including nucleic acid extraction, reagent preparation, LAMP reaction, and signal detection. By simply adding a sample, it can simultaneously detect four types of foodborne pathogens, making it advantageous for the analysis of complex samples and improving detection accuracy. Additionally, freeze-dried reagents are integrated into the fully enclosed microfluidic chip cartridge, which allows the reagents to be transported and stored at room temperature, greatly reducing the cost of detection. It has been successfully applied in actual samples contaminated with multiple foodborne pathogens and has excellent stability. The entire detection process can be completed in 45 minutes, with a sensitivity of approximately 500 CFU mL<small><sup>−1</sup></small>. Therefore, the automated microfluidic device would be adequate for point-of-care testing (POCT) with high simplicity and high speed, providing an advanced genetic analysis microsystem for foodborne pathogen detection.</p>\",\"PeriodicalId\":85,\"journal\":{\"name\":\"Lab on a Chip\",\"volume\":\" 14\",\"pages\":\" 3537-3548\"},\"PeriodicalIF\":5.4000,\"publicationDate\":\"2025-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Lab on a Chip\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2025/lc/d4lc00819g\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lab on a Chip","FirstCategoryId":"5","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/lc/d4lc00819g","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Point-of-care analysis for foodborne pathogens in food samples based on a fully enclosed microfluidic chip cartridge
Foodborne pathogens endanger public health and rapid, sensitive, and accurate detection of them is vital. Portable, highly integrated detection devices have great application prospects in the screening and analysis of foodborne pathogens. In this study, a fully automated detection device based on a fully enclosed microfluidic chip cartridge was successfully designed. This device integrates multiple functions, including nucleic acid extraction, reagent preparation, LAMP reaction, and signal detection. By simply adding a sample, it can simultaneously detect four types of foodborne pathogens, making it advantageous for the analysis of complex samples and improving detection accuracy. Additionally, freeze-dried reagents are integrated into the fully enclosed microfluidic chip cartridge, which allows the reagents to be transported and stored at room temperature, greatly reducing the cost of detection. It has been successfully applied in actual samples contaminated with multiple foodborne pathogens and has excellent stability. The entire detection process can be completed in 45 minutes, with a sensitivity of approximately 500 CFU mL−1. Therefore, the automated microfluidic device would be adequate for point-of-care testing (POCT) with high simplicity and high speed, providing an advanced genetic analysis microsystem for foodborne pathogen detection.
期刊介绍:
Lab on a Chip is the premiere journal that publishes cutting-edge research in the field of miniaturization. By their very nature, microfluidic/nanofluidic/miniaturized systems are at the intersection of disciplines, spanning fundamental research to high-end application, which is reflected by the broad readership of the journal. Lab on a Chip publishes two types of papers on original research: full-length research papers and communications. Papers should demonstrate innovations, which can come from technical advancements or applications addressing pressing needs in globally important areas. The journal also publishes Comments, Reviews, and Perspectives.