{"title":"注射成型中纤维取向的发展:玻璃纤维、碳纤维及其混杂复合材料的比较","authors":"Subhabrata Saha ,&nbsp;Vipin Kumar ,&nbsp;Bhagyashree Prabhune ,&nbsp;Madhura Limaye ,&nbsp;Brittany Rodriguez ,&nbsp;Nikhil Garg ,&nbsp;Seokpum Kim ,&nbsp;Ahmed A. Hassen ,&nbsp;Nikolaos Tsiamis ,&nbsp;Yalcin Meraki ,&nbsp;Uday Vaidya ,&nbsp;Marc-Henry Wakim ,&nbsp;Steve Ouendag ,&nbsp;Oskar Sjogren","doi":"10.1016/j.coco.2025.102496","DOIUrl":null,"url":null,"abstract":"<div><div>Fiber orientation distribution (FOD) in injection-molded panels with respect to distance from the gate was analyzed using X-ray computed tomography (X-CT) for glass fiber (GF), carbon fiber (CF), and hybrid CF/GF (CGF) reinforced nylon 66. To understand the reason behind the FOD with different fiber types, computational fluid dynamics (CFD) and rheology were performed. Samples were extracted at three locations: near the gate, center, and opposite end. Thickness of the layers of typical skin-shell-core type FOD varied with fiber type and location. GF achieved flow direction alignment (in shell) earlier than viscous CF and CGF near the gate, whereas CF showed the highest flow-direction alignment at the center due to shear induced orientation. At the opposite end, GF experienced more backflow than others indicating faster mold filling owing to its lower viscosity. Hybrid CGF exhibited GF-dominated center and CF-dominated end region. The numerical model used to obtain FOD and rheological predictions for the CF and GF composites served to corroborate the trends observed in the experimental trials. The FOD responses across fiber types and location were reflected in their longitudinal and transverse properties. Only GF showed higher longitudinal modulus over transverse modulus near the gate attributed to rapid alignment, whereas CF and CGF exhibited opposite trend. However, fountain flow enhanced the longitudinal modulus over transverse modulus with the distance for all, particularly for CF. This study offers insights into mold filling behavior of different fibers which are critical in optimizing injection molding conditions for tailored final properties.</div></div>","PeriodicalId":10533,"journal":{"name":"Composites Communications","volume":"58 ","pages":"Article 102496"},"PeriodicalIF":7.7000,"publicationDate":"2025-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of fiber orientation in injection molding: Comparison of glass fiber, carbon fiber and their hybrid composites\",\"authors\":\"Subhabrata Saha ,&nbsp;Vipin Kumar ,&nbsp;Bhagyashree Prabhune ,&nbsp;Madhura Limaye ,&nbsp;Brittany Rodriguez ,&nbsp;Nikhil Garg ,&nbsp;Seokpum Kim ,&nbsp;Ahmed A. Hassen ,&nbsp;Nikolaos Tsiamis ,&nbsp;Yalcin Meraki ,&nbsp;Uday Vaidya ,&nbsp;Marc-Henry Wakim ,&nbsp;Steve Ouendag ,&nbsp;Oskar Sjogren\",\"doi\":\"10.1016/j.coco.2025.102496\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Fiber orientation distribution (FOD) in injection-molded panels with respect to distance from the gate was analyzed using X-ray computed tomography (X-CT) for glass fiber (GF), carbon fiber (CF), and hybrid CF/GF (CGF) reinforced nylon 66. To understand the reason behind the FOD with different fiber types, computational fluid dynamics (CFD) and rheology were performed. Samples were extracted at three locations: near the gate, center, and opposite end. Thickness of the layers of typical skin-shell-core type FOD varied with fiber type and location. GF achieved flow direction alignment (in shell) earlier than viscous CF and CGF near the gate, whereas CF showed the highest flow-direction alignment at the center due to shear induced orientation. At the opposite end, GF experienced more backflow than others indicating faster mold filling owing to its lower viscosity. Hybrid CGF exhibited GF-dominated center and CF-dominated end region. The numerical model used to obtain FOD and rheological predictions for the CF and GF composites served to corroborate the trends observed in the experimental trials. The FOD responses across fiber types and location were reflected in their longitudinal and transverse properties. Only GF showed higher longitudinal modulus over transverse modulus near the gate attributed to rapid alignment, whereas CF and CGF exhibited opposite trend. However, fountain flow enhanced the longitudinal modulus over transverse modulus with the distance for all, particularly for CF. This study offers insights into mold filling behavior of different fibers which are critical in optimizing injection molding conditions for tailored final properties.</div></div>\",\"PeriodicalId\":10533,\"journal\":{\"name\":\"Composites Communications\",\"volume\":\"58 \",\"pages\":\"Article 102496\"},\"PeriodicalIF\":7.7000,\"publicationDate\":\"2025-06-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Composites Communications\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2452213925002499\",\"RegionNum\":2,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MATERIALS SCIENCE, COMPOSITES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Composites Communications","FirstCategoryId":"88","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2452213925002499","RegionNum":2,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATERIALS SCIENCE, COMPOSITES","Score":null,"Total":0}
引用次数: 0

摘要

利用x射线计算机断层扫描(X-CT)对玻璃纤维(GF)、碳纤维(CF)和CF/GF混合增强尼龙66的注射成型板中纤维取向分布(FOD)与浇口距离进行了分析。为了了解不同纤维类型的FOD背后的原因,进行了计算流体力学(CFD)和流变学研究。样品在三个位置提取:靠近门、中心和对端。典型的皮壳芯型FOD的层厚随纤维类型和位置的不同而变化。GF比粘性CF和CGF在靠近浇口处更早实现流向对齐(在壳内),而CF由于剪切诱导取向在中心处表现出最高的流向对齐。在另一端,GF经历了更多的回流比其他表明更快的模具填充由于其较低的粘度。杂化CGF表现为中心以gf为主,端区以cf为主。用于获得CF和GF复合材料FOD和流变预测的数值模型证实了在实验试验中观察到的趋势。不同纤维类型和位置的FOD响应反映在其纵向和横向特性上。在栅极附近,由于快速对准,只有GF的纵向模量高于横向模量,而CF和CGF的趋势相反。然而,喷泉流动随着距离的增加,纵向模量比横向模量增强,特别是CF。这项研究提供了不同纤维的模具填充行为的见解,这对于优化注塑条件以定制最终性能至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of fiber orientation in injection molding: Comparison of glass fiber, carbon fiber and their hybrid composites
Fiber orientation distribution (FOD) in injection-molded panels with respect to distance from the gate was analyzed using X-ray computed tomography (X-CT) for glass fiber (GF), carbon fiber (CF), and hybrid CF/GF (CGF) reinforced nylon 66. To understand the reason behind the FOD with different fiber types, computational fluid dynamics (CFD) and rheology were performed. Samples were extracted at three locations: near the gate, center, and opposite end. Thickness of the layers of typical skin-shell-core type FOD varied with fiber type and location. GF achieved flow direction alignment (in shell) earlier than viscous CF and CGF near the gate, whereas CF showed the highest flow-direction alignment at the center due to shear induced orientation. At the opposite end, GF experienced more backflow than others indicating faster mold filling owing to its lower viscosity. Hybrid CGF exhibited GF-dominated center and CF-dominated end region. The numerical model used to obtain FOD and rheological predictions for the CF and GF composites served to corroborate the trends observed in the experimental trials. The FOD responses across fiber types and location were reflected in their longitudinal and transverse properties. Only GF showed higher longitudinal modulus over transverse modulus near the gate attributed to rapid alignment, whereas CF and CGF exhibited opposite trend. However, fountain flow enhanced the longitudinal modulus over transverse modulus with the distance for all, particularly for CF. This study offers insights into mold filling behavior of different fibers which are critical in optimizing injection molding conditions for tailored final properties.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Composites Communications
Composites Communications Materials Science-Ceramics and Composites
CiteScore
12.10
自引率
10.00%
发文量
340
审稿时长
36 days
期刊介绍: Composites Communications (Compos. Commun.) is a peer-reviewed journal publishing short communications and letters on the latest advances in composites science and technology. With a rapid review and publication process, its goal is to disseminate new knowledge promptly within the composites community. The journal welcomes manuscripts presenting creative concepts and new findings in design, state-of-the-art approaches in processing, synthesis, characterization, and mechanics modeling. In addition to traditional fiber-/particulate-reinforced engineering composites, it encourages submissions on composites with exceptional physical, mechanical, and fracture properties, as well as those with unique functions and significant application potential. This includes biomimetic and bio-inspired composites for biomedical applications, functional nano-composites for thermal management and energy applications, and composites designed for extreme service environments.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信