{"title":"正畸透明对准器的清洁溶液:微生物和比色分析。","authors":"Paula Cristina Henriques da Silva, Beatriz Ribeiro Ribas, Tony Vieira Faria, Janaína Habib Jorge, Luiz Gonzaga Gandini, Ary Dos Santos-Pinto, João Roberto Gonçalves, Jonas Bianchi","doi":"10.1590/2177-6709.30.2.e2524262.oar","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This in-vitro study aimed to evaluate the antibacterial efficacy and color changes induced by different chemical agents on the orthodontic aligners.</p><p><strong>Methods: </strong>The sample consisted of Invisalign® aligners materials and seven solutions were tested: sodium hypochlorite (HYP), sodium bicarbonate (BIC), neutral detergent (DET), chlorhexidine gluconate (CX), white vinegar (VIN) diluted in water (1:3), Corega Tabs® effervescent tablets (COR), and distilled water (DW, control group). The microbiological control was evaluated by analyzing cell proliferation (CFU/ml) and cell metabolism (AlamarBlue® test), and the VITA EasyShade® Advance spectrophotometer was used for color change analysis, using multiple Mann-Whitney tests.</p><p><strong>Results: </strong>All solutions significantly reduced S. mutans biofilm (CFU/mL), except for the control group. The AlamarBlue® analysis showed a significant reduction in cell viability, except for the BIC solution (p=0.183). After 7 days, HYP showed significant color variation, compared to all the other solutions, except for the control group (p=0.095). After 14 days, BIC and CX showed significantly greater color variation than the control group (p=0.007). DET showed a large difference compared to BIC and CX (p=0.007), and a statistically significant difference compared to VIN and COR (p=0.015).</p><p><strong>Conclusion: </strong>The disinfectant solutions HYP, DET, CX, VIN, and COR significantly reduced the bacterial colonies of S. mutans and cellular metabolism. In addition, HYP, BIC, CX, and COR significantly affected the material color.</p>","PeriodicalId":38720,"journal":{"name":"Dental Press Journal of Orthodontics","volume":"30 2","pages":"e2524262"},"PeriodicalIF":0.0000,"publicationDate":"2025-05-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12133152/pdf/","citationCount":"0","resultStr":"{\"title\":\"Cleaning solutions for orthodontic clear aligners: a microbiological and colorimetric analysis.\",\"authors\":\"Paula Cristina Henriques da Silva, Beatriz Ribeiro Ribas, Tony Vieira Faria, Janaína Habib Jorge, Luiz Gonzaga Gandini, Ary Dos Santos-Pinto, João Roberto Gonçalves, Jonas Bianchi\",\"doi\":\"10.1590/2177-6709.30.2.e2524262.oar\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>This in-vitro study aimed to evaluate the antibacterial efficacy and color changes induced by different chemical agents on the orthodontic aligners.</p><p><strong>Methods: </strong>The sample consisted of Invisalign® aligners materials and seven solutions were tested: sodium hypochlorite (HYP), sodium bicarbonate (BIC), neutral detergent (DET), chlorhexidine gluconate (CX), white vinegar (VIN) diluted in water (1:3), Corega Tabs® effervescent tablets (COR), and distilled water (DW, control group). The microbiological control was evaluated by analyzing cell proliferation (CFU/ml) and cell metabolism (AlamarBlue® test), and the VITA EasyShade® Advance spectrophotometer was used for color change analysis, using multiple Mann-Whitney tests.</p><p><strong>Results: </strong>All solutions significantly reduced S. mutans biofilm (CFU/mL), except for the control group. The AlamarBlue® analysis showed a significant reduction in cell viability, except for the BIC solution (p=0.183). After 7 days, HYP showed significant color variation, compared to all the other solutions, except for the control group (p=0.095). After 14 days, BIC and CX showed significantly greater color variation than the control group (p=0.007). DET showed a large difference compared to BIC and CX (p=0.007), and a statistically significant difference compared to VIN and COR (p=0.015).</p><p><strong>Conclusion: </strong>The disinfectant solutions HYP, DET, CX, VIN, and COR significantly reduced the bacterial colonies of S. mutans and cellular metabolism. In addition, HYP, BIC, CX, and COR significantly affected the material color.</p>\",\"PeriodicalId\":38720,\"journal\":{\"name\":\"Dental Press Journal of Orthodontics\",\"volume\":\"30 2\",\"pages\":\"e2524262\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-05-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12133152/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dental Press Journal of Orthodontics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/2177-6709.30.2.e2524262.oar\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Press Journal of Orthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/2177-6709.30.2.e2524262.oar","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价不同化学药剂对正畸矫正器的抗菌效果及颜色变化。方法:样品由Invisalign®矫正器材料组成,检测7种溶液:次氯酸钠(HYP)、碳酸氢钠(BIC)、中性洗涤剂(DET)、葡萄糖酸氯己定(CX)、水(1:3)稀释的白醋(VIN)、Corega Tabs®泡腾片(COR)和蒸馏水(DW,对照组)。微生物控制通过分析细胞增殖(CFU/ml)和细胞代谢(AlamarBlue®测试)进行评估,使用VITA EasyShade®Advance分光光度计进行颜色变化分析,采用多项Mann-Whitney测试。结果:除对照组外,所有溶液均显著降低变形链球菌生物膜(CFU/mL)。AlamarBlue®分析显示,除BIC溶液外,细胞活力显著降低(p=0.183)。7天后,除对照组外,与其他所有溶液相比,HYP的颜色变化显著(p=0.095)。14 d后,BIC组和CX组的颜色变化明显大于对照组(p=0.007)。DET与BIC、CX比较差异较大(p=0.007),与VIN、COR比较差异有统计学意义(p=0.015)。结论:HYP、DET、CX、VIN、COR消毒液均能显著降低变形链球菌菌落,降低细胞代谢。此外,HYP、BIC、CX和COR对材料颜色有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Cleaning solutions for orthodontic clear aligners: a microbiological and colorimetric analysis.

Objective: This in-vitro study aimed to evaluate the antibacterial efficacy and color changes induced by different chemical agents on the orthodontic aligners.

Methods: The sample consisted of Invisalign® aligners materials and seven solutions were tested: sodium hypochlorite (HYP), sodium bicarbonate (BIC), neutral detergent (DET), chlorhexidine gluconate (CX), white vinegar (VIN) diluted in water (1:3), Corega Tabs® effervescent tablets (COR), and distilled water (DW, control group). The microbiological control was evaluated by analyzing cell proliferation (CFU/ml) and cell metabolism (AlamarBlue® test), and the VITA EasyShade® Advance spectrophotometer was used for color change analysis, using multiple Mann-Whitney tests.

Results: All solutions significantly reduced S. mutans biofilm (CFU/mL), except for the control group. The AlamarBlue® analysis showed a significant reduction in cell viability, except for the BIC solution (p=0.183). After 7 days, HYP showed significant color variation, compared to all the other solutions, except for the control group (p=0.095). After 14 days, BIC and CX showed significantly greater color variation than the control group (p=0.007). DET showed a large difference compared to BIC and CX (p=0.007), and a statistically significant difference compared to VIN and COR (p=0.015).

Conclusion: The disinfectant solutions HYP, DET, CX, VIN, and COR significantly reduced the bacterial colonies of S. mutans and cellular metabolism. In addition, HYP, BIC, CX, and COR significantly affected the material color.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Dental Press Journal of Orthodontics
Dental Press Journal of Orthodontics Dentistry-Orthodontics
CiteScore
2.00
自引率
0.00%
发文量
40
审稿时长
27 weeks
期刊介绍: The Dental Press Journal of Orthodontics publishes scientific research articles, significant reviews, clinical and technical case reports, brief communications, and other materials related to Orthodontics and Facial Orthopedics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信