João Pedro Justino DE Oliveira Limirio, Jéssica Marcela de Luna Gomes, Joel Ferreira Santiago-Junior, Cleidiel Aparecido Araújo Lemos, Maria Cristina Rosifini Alves Rezende, Eduardo Piza Pellizzer
{"title":"cocr基基基牙的制造方法和使用对种植体修复体垂直和水平边缘配合和扭矩损失的影响。","authors":"João Pedro Justino DE Oliveira Limirio, Jéssica Marcela de Luna Gomes, Joel Ferreira Santiago-Junior, Cleidiel Aparecido Araújo Lemos, Maria Cristina Rosifini Alves Rezende, Eduardo Piza Pellizzer","doi":"10.1590/1678-7757-2024-0589","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This in vitro study evaluated implant-supported single crowns with external connections fabricated using different techniques (cast and CAD/CAM) and materials (metal-ceramic and translucent zirconia) regarding vertical and horizontal marginal fit and torque loss before and after mechanical cycling.</p><p><strong>Methodology: </strong>A total of 50 specimens prepared using cast (lost wax) and CAD/CAM were divided into five groups-MC (metal-ceramic crowns), ZrB (Co-Cr base, coping milled in zirconia and feldspathic ceramic veneering), Zr (coping milled in zirconia and feldspathic ceramic veneering), MZrB (Co-Cr base and monolithic translucent zirconia crown), and MZr (monolithic translucent zirconia crown)-and subjected to 5×10⁶ mechanical cycles at a 30° angle at 37°C, and an applied load of 150N at 2Hz. All crowns were screwed with a 30Ncm torque. Vertical and horizontal marginal misfit (measured using a 3D optical microscope) and torque loss were assessed before and after mechanical cycling. Statistical analyses used a significance value of 0.05.</p><p><strong>Results: </strong>Before cycling, MC (93.93±22.84µm) and MZrB (66.12±11.87µm) (p<0.05) crowns showed significantly higher vertical marginal misfit values than Zr (49.92±3µm) and MZr (49.76±3,9µm). ZrB (59.96±4.66µm) crowns exhibited no statistically significant difference when compared with the other groups. MC crowns presented the highest horizontal marginal misfit values before and after cycling in group comparisons (p<0.05). MZrB had the highest torque loss (10N), with a statically significant difference when compared with MZr and Zr (p<0.05). Comparison between all groups showed no significant difference regarding the effect of mechanical cycling (p>0.05).</p><p><strong>Conclusion: </strong>CAD/CAM manufacturing resulted in lower vertical and horizontal marginal misfit values, especially for monolithic translucent zirconia crowns (MZr) before and after mechanical cycling. All groups presented torque loss before and after mechanical cycling.</p>","PeriodicalId":15133,"journal":{"name":"Journal of Applied Oral Science","volume":"33 ","pages":"e20240589"},"PeriodicalIF":2.6000,"publicationDate":"2025-05-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12212057/pdf/","citationCount":"0","resultStr":"{\"title\":\"Influence of manufacturing methods and use of CoCr-based abutments on vertical and horizontal marginal fit and torque loss in implant-supported prostheses.\",\"authors\":\"João Pedro Justino DE Oliveira Limirio, Jéssica Marcela de Luna Gomes, Joel Ferreira Santiago-Junior, Cleidiel Aparecido Araújo Lemos, Maria Cristina Rosifini Alves Rezende, Eduardo Piza Pellizzer\",\"doi\":\"10.1590/1678-7757-2024-0589\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>This in vitro study evaluated implant-supported single crowns with external connections fabricated using different techniques (cast and CAD/CAM) and materials (metal-ceramic and translucent zirconia) regarding vertical and horizontal marginal fit and torque loss before and after mechanical cycling.</p><p><strong>Methodology: </strong>A total of 50 specimens prepared using cast (lost wax) and CAD/CAM were divided into five groups-MC (metal-ceramic crowns), ZrB (Co-Cr base, coping milled in zirconia and feldspathic ceramic veneering), Zr (coping milled in zirconia and feldspathic ceramic veneering), MZrB (Co-Cr base and monolithic translucent zirconia crown), and MZr (monolithic translucent zirconia crown)-and subjected to 5×10⁶ mechanical cycles at a 30° angle at 37°C, and an applied load of 150N at 2Hz. All crowns were screwed with a 30Ncm torque. Vertical and horizontal marginal misfit (measured using a 3D optical microscope) and torque loss were assessed before and after mechanical cycling. Statistical analyses used a significance value of 0.05.</p><p><strong>Results: </strong>Before cycling, MC (93.93±22.84µm) and MZrB (66.12±11.87µm) (p<0.05) crowns showed significantly higher vertical marginal misfit values than Zr (49.92±3µm) and MZr (49.76±3,9µm). ZrB (59.96±4.66µm) crowns exhibited no statistically significant difference when compared with the other groups. MC crowns presented the highest horizontal marginal misfit values before and after cycling in group comparisons (p<0.05). MZrB had the highest torque loss (10N), with a statically significant difference when compared with MZr and Zr (p<0.05). Comparison between all groups showed no significant difference regarding the effect of mechanical cycling (p>0.05).</p><p><strong>Conclusion: </strong>CAD/CAM manufacturing resulted in lower vertical and horizontal marginal misfit values, especially for monolithic translucent zirconia crowns (MZr) before and after mechanical cycling. All groups presented torque loss before and after mechanical cycling.</p>\",\"PeriodicalId\":15133,\"journal\":{\"name\":\"Journal of Applied Oral Science\",\"volume\":\"33 \",\"pages\":\"e20240589\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2025-05-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12212057/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Oral Science\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1590/1678-7757-2024-0589\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Oral Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/1678-7757-2024-0589","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Influence of manufacturing methods and use of CoCr-based abutments on vertical and horizontal marginal fit and torque loss in implant-supported prostheses.
Objectives: This in vitro study evaluated implant-supported single crowns with external connections fabricated using different techniques (cast and CAD/CAM) and materials (metal-ceramic and translucent zirconia) regarding vertical and horizontal marginal fit and torque loss before and after mechanical cycling.
Methodology: A total of 50 specimens prepared using cast (lost wax) and CAD/CAM were divided into five groups-MC (metal-ceramic crowns), ZrB (Co-Cr base, coping milled in zirconia and feldspathic ceramic veneering), Zr (coping milled in zirconia and feldspathic ceramic veneering), MZrB (Co-Cr base and monolithic translucent zirconia crown), and MZr (monolithic translucent zirconia crown)-and subjected to 5×10⁶ mechanical cycles at a 30° angle at 37°C, and an applied load of 150N at 2Hz. All crowns were screwed with a 30Ncm torque. Vertical and horizontal marginal misfit (measured using a 3D optical microscope) and torque loss were assessed before and after mechanical cycling. Statistical analyses used a significance value of 0.05.
Results: Before cycling, MC (93.93±22.84µm) and MZrB (66.12±11.87µm) (p<0.05) crowns showed significantly higher vertical marginal misfit values than Zr (49.92±3µm) and MZr (49.76±3,9µm). ZrB (59.96±4.66µm) crowns exhibited no statistically significant difference when compared with the other groups. MC crowns presented the highest horizontal marginal misfit values before and after cycling in group comparisons (p<0.05). MZrB had the highest torque loss (10N), with a statically significant difference when compared with MZr and Zr (p<0.05). Comparison between all groups showed no significant difference regarding the effect of mechanical cycling (p>0.05).
Conclusion: CAD/CAM manufacturing resulted in lower vertical and horizontal marginal misfit values, especially for monolithic translucent zirconia crowns (MZr) before and after mechanical cycling. All groups presented torque loss before and after mechanical cycling.
期刊介绍:
The Journal of Applied Oral Science is committed in publishing the scientific and technologic advances achieved by the dental community, according to the quality indicators and peer reviewed material, with the objective of assuring its acceptability at the local, regional, national and international levels. The primary goal of The Journal of Applied Oral Science is to publish the outcomes of original investigations as well as invited case reports and invited reviews in the field of Dentistry and related areas.