使用Reciproc、Hyflex CM和Prodesign Duo Hybrid系统对弯曲根管进行再治疗。

IF 1.5 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Brazilian oral research Pub Date : 2025-06-02 eCollection Date: 2025-01-01 DOI:10.1590/1807-3107bor-2025.vol39.061
Amanda Garcia Alves Maliza, Renata Maíra de Souza Leal, Bruno Cavalini Cavenago, Murilo Priori Alcalde, Rodrigo Ricci Vivan, Marco Antônio Húngaro Duarte
{"title":"使用Reciproc、Hyflex CM和Prodesign Duo Hybrid系统对弯曲根管进行再治疗。","authors":"Amanda Garcia Alves Maliza, Renata Maíra de Souza Leal, Bruno Cavalini Cavenago, Murilo Priori Alcalde, Rodrigo Ricci Vivan, Marco Antônio Húngaro Duarte","doi":"10.1590/1807-3107bor-2025.vol39.061","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this ex vivo study was to evaluate the efficacy of the Reciproc, Hyflex CM, and ProDesign Duo Hybrid in the retreatment of mesial root canals with Vertucci Type 4 of mandibular molars with curvatures between 10 and 20 degrees. Forty-five mesial roots of mandibular molars were prepared up to size 25.06 Nickel-Titanium (NiTi) file and filled by the single cone technique. The roots were then divided into 3 groups according to retreatment procedures: Reciproc R25 followed by R40; Hyflex 25.04 followed by 40.04; ProDesign Duo Hybrid 25.06 followed by 40.05. The canals were irrigated with 1 mL 1% sodium hypochlorite, and a final rinse was performed with 5 mL 17% EDTA for 3 minutes. Microcomputed tomography scans were performed in each step of the procedure to evaluate root canal transportation at distances of 2, 4, 6, 8 and 10 mm from the apex and volume of endodontic filling remaining at segments of 1-3, 3-5, and 5-7 mm from the apex. The filling material that was not removed during retreatment was evaluated by confocal laser scanning and the percentage after each procedure was expressed in terms of percentage of the initial root-filling material volume. The time taken to remove the material and re-instrumentation was measured in seconds with a digital chronometer. Statistical analysis was performed with t-paired, ANOVA, Kruskal-Wallis and Friedman tests (p < 0.05). In all groups, sections at 4, 6, 8, and 10 mm from the apex were transported to the danger zone, towards the furcation. However, the section at 2 mm from the apex was transported in opposite direction to the furcation, but no statistically significant differences (p > 0.05) in canal transportation and filling material removal were found between the 3 groups. Filling removal and re-instrumentation took significantly (p < 0.05) less time in the Reciproc group. None of the retreatment techniques completely removed the root fillings. The results suggest that no difference exists between the groups in apical transportation of curved canals. The Reciproc system took less time for filling removal and re-instrumentation and the combination of reciprocating and rotary files in the retreatment of curved canals was as efficient as rotary and reciprocating motion.</p>","PeriodicalId":9240,"journal":{"name":"Brazilian oral research","volume":"39 ","pages":"e061"},"PeriodicalIF":1.5000,"publicationDate":"2025-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12129459/pdf/","citationCount":"0","resultStr":"{\"title\":\"Endodontic retreatment of curved canals using Reciproc, Hyflex CM and Prodesign Duo Hybrid Systems.\",\"authors\":\"Amanda Garcia Alves Maliza, Renata Maíra de Souza Leal, Bruno Cavalini Cavenago, Murilo Priori Alcalde, Rodrigo Ricci Vivan, Marco Antônio Húngaro Duarte\",\"doi\":\"10.1590/1807-3107bor-2025.vol39.061\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of this ex vivo study was to evaluate the efficacy of the Reciproc, Hyflex CM, and ProDesign Duo Hybrid in the retreatment of mesial root canals with Vertucci Type 4 of mandibular molars with curvatures between 10 and 20 degrees. Forty-five mesial roots of mandibular molars were prepared up to size 25.06 Nickel-Titanium (NiTi) file and filled by the single cone technique. The roots were then divided into 3 groups according to retreatment procedures: Reciproc R25 followed by R40; Hyflex 25.04 followed by 40.04; ProDesign Duo Hybrid 25.06 followed by 40.05. The canals were irrigated with 1 mL 1% sodium hypochlorite, and a final rinse was performed with 5 mL 17% EDTA for 3 minutes. Microcomputed tomography scans were performed in each step of the procedure to evaluate root canal transportation at distances of 2, 4, 6, 8 and 10 mm from the apex and volume of endodontic filling remaining at segments of 1-3, 3-5, and 5-7 mm from the apex. The filling material that was not removed during retreatment was evaluated by confocal laser scanning and the percentage after each procedure was expressed in terms of percentage of the initial root-filling material volume. The time taken to remove the material and re-instrumentation was measured in seconds with a digital chronometer. Statistical analysis was performed with t-paired, ANOVA, Kruskal-Wallis and Friedman tests (p < 0.05). In all groups, sections at 4, 6, 8, and 10 mm from the apex were transported to the danger zone, towards the furcation. However, the section at 2 mm from the apex was transported in opposite direction to the furcation, but no statistically significant differences (p > 0.05) in canal transportation and filling material removal were found between the 3 groups. Filling removal and re-instrumentation took significantly (p < 0.05) less time in the Reciproc group. None of the retreatment techniques completely removed the root fillings. The results suggest that no difference exists between the groups in apical transportation of curved canals. The Reciproc system took less time for filling removal and re-instrumentation and the combination of reciprocating and rotary files in the retreatment of curved canals was as efficient as rotary and reciprocating motion.</p>\",\"PeriodicalId\":9240,\"journal\":{\"name\":\"Brazilian oral research\",\"volume\":\"39 \",\"pages\":\"e061\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2025-06-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12129459/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Brazilian oral research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1590/1807-3107bor-2025.vol39.061\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian oral research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/1807-3107bor-2025.vol39.061","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

本离体研究的目的是评估Reciproc、Hyflex CM和ProDesign Duo Hybrid在弯曲度在10 - 20度之间的下颌磨牙Vertucci 4型近中根管再治疗中的疗效。采用镍钛(NiTi)锉大小为25.06的方法制备45颗下颌磨牙近中根,并采用单锥体技术进行充填。根按再处理程序分为3组:R25再R40;Hyflex 25.04紧随其后,为40.04;ProDesign Duo Hybrid以25.06紧随其后,为40.05。用1ml 1%次氯酸钠冲洗根管,最后用5ml 17% EDTA冲洗3分钟。在手术的每一步中都进行了显微计算机断层扫描,以评估距离根尖2、4、6、8和10毫米的根管运输情况,以及距离根尖1-3、3-5和5-7毫米的根管填充量。再治疗过程中未移除的填充材料通过共聚焦激光扫描进行评估,每次手术后的百分比以初始根填充材料体积的百分比表示。移除材料和重新测量仪器所用的时间用数字计时器以秒为单位测量。统计学分析采用t-配对、方差分析、Kruskal-Wallis和Friedman检验(p < 0.05)。在所有的组中,4、6、8和10 mm的断面都被运送到危险区域,朝向分叉。而离根尖2 mm处的断面与根分叉方向相反,但三组间根管移动和填充物清除差异无统计学意义(p > 0.05)。Reciproc组补牙清除和补牙时间显著缩短(p < 0.05)。没有一种再处理技术能完全去除牙根充填物。结果表明,两组间弯曲管的根尖运输没有差异。往复锉和旋转锉的组合在弯曲管的再处理中与旋转锉和往复锉的组合一样有效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Endodontic retreatment of curved canals using Reciproc, Hyflex CM and Prodesign Duo Hybrid Systems.

The aim of this ex vivo study was to evaluate the efficacy of the Reciproc, Hyflex CM, and ProDesign Duo Hybrid in the retreatment of mesial root canals with Vertucci Type 4 of mandibular molars with curvatures between 10 and 20 degrees. Forty-five mesial roots of mandibular molars were prepared up to size 25.06 Nickel-Titanium (NiTi) file and filled by the single cone technique. The roots were then divided into 3 groups according to retreatment procedures: Reciproc R25 followed by R40; Hyflex 25.04 followed by 40.04; ProDesign Duo Hybrid 25.06 followed by 40.05. The canals were irrigated with 1 mL 1% sodium hypochlorite, and a final rinse was performed with 5 mL 17% EDTA for 3 minutes. Microcomputed tomography scans were performed in each step of the procedure to evaluate root canal transportation at distances of 2, 4, 6, 8 and 10 mm from the apex and volume of endodontic filling remaining at segments of 1-3, 3-5, and 5-7 mm from the apex. The filling material that was not removed during retreatment was evaluated by confocal laser scanning and the percentage after each procedure was expressed in terms of percentage of the initial root-filling material volume. The time taken to remove the material and re-instrumentation was measured in seconds with a digital chronometer. Statistical analysis was performed with t-paired, ANOVA, Kruskal-Wallis and Friedman tests (p < 0.05). In all groups, sections at 4, 6, 8, and 10 mm from the apex were transported to the danger zone, towards the furcation. However, the section at 2 mm from the apex was transported in opposite direction to the furcation, but no statistically significant differences (p > 0.05) in canal transportation and filling material removal were found between the 3 groups. Filling removal and re-instrumentation took significantly (p < 0.05) less time in the Reciproc group. None of the retreatment techniques completely removed the root fillings. The results suggest that no difference exists between the groups in apical transportation of curved canals. The Reciproc system took less time for filling removal and re-instrumentation and the combination of reciprocating and rotary files in the retreatment of curved canals was as efficient as rotary and reciprocating motion.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.70
自引率
4.00%
发文量
107
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信