{"title":"斜视再手术中前段光学相干断层扫描测量的可靠性评估:一项三级保健中心的研究。","authors":"Kamini Singh, Aarushi Saini, Vaishali Tomar, Kanchita Pandey, Mittali Khurana, Tipu Sultan, Subhash Dadeya","doi":"10.1080/09273972.2025.2512788","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objectives:</i> To evaluate the accuracy of Anterior Segment Optical Coherence Tomography (ASOCT) in measuring the limbal muscle insertion distance (LMID) of previously operated horizontal recti muscles in strabismus reoperations, compared to intraoperative caliper measurements. <i>Methods:</i> Thirty adult patients (60 muscles) undergoing strabismus reoperation of horizontal recti muscles for residual/consecutive strabismus were enrolled. Enrolled subjects underwent preoperative ASOCT measurements of the LMID of previously operated horizontal recti muscles, which were compared with intraoperative caliper values obtained during reoperation. <i>Results:</i> ASOCT successfully imaged 90% of the muscles. The mean LMID for medial rectus (MR) and lateral rectus (LR) measured by ASOCT was 7.96 ± 2.02 mm and 8.74 ± 2.81 mm, respectively, which were within 1 mm of intraoperative caliper measurements (7.93 ± 2.81 mm for MR, 9.03 ± 2.79 mm for LR). Bland-Altman plot showed a strong agreement for MR and a good agreement for LR between the two measured values, with excellent interclass correlation coefficients between the two methods of measurement (MR: 0.96, LR: 0.98; <i>p</i> < .001). <i>Conclusion:</i> In our study, 100% of LMIDs that could be visualized using ASOCT were within 1 mm of their intraoperative measured values. Therefore, ASOCT is a reliable tool for measuring the LMID of previously operated horizontal recti muscles, where the scarred tissue from older surgeries/lost data about previous surgeries makes it difficult for the operating surgeon to plan reoperations.</p>","PeriodicalId":51700,"journal":{"name":"Strabismus","volume":" ","pages":"1-9"},"PeriodicalIF":0.8000,"publicationDate":"2025-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of the reliability of anterior segment optical coherence tomography measurements in cases of strabismus reoperations: a tertiary care center study.\",\"authors\":\"Kamini Singh, Aarushi Saini, Vaishali Tomar, Kanchita Pandey, Mittali Khurana, Tipu Sultan, Subhash Dadeya\",\"doi\":\"10.1080/09273972.2025.2512788\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><i>Objectives:</i> To evaluate the accuracy of Anterior Segment Optical Coherence Tomography (ASOCT) in measuring the limbal muscle insertion distance (LMID) of previously operated horizontal recti muscles in strabismus reoperations, compared to intraoperative caliper measurements. <i>Methods:</i> Thirty adult patients (60 muscles) undergoing strabismus reoperation of horizontal recti muscles for residual/consecutive strabismus were enrolled. Enrolled subjects underwent preoperative ASOCT measurements of the LMID of previously operated horizontal recti muscles, which were compared with intraoperative caliper values obtained during reoperation. <i>Results:</i> ASOCT successfully imaged 90% of the muscles. The mean LMID for medial rectus (MR) and lateral rectus (LR) measured by ASOCT was 7.96 ± 2.02 mm and 8.74 ± 2.81 mm, respectively, which were within 1 mm of intraoperative caliper measurements (7.93 ± 2.81 mm for MR, 9.03 ± 2.79 mm for LR). Bland-Altman plot showed a strong agreement for MR and a good agreement for LR between the two measured values, with excellent interclass correlation coefficients between the two methods of measurement (MR: 0.96, LR: 0.98; <i>p</i> < .001). <i>Conclusion:</i> In our study, 100% of LMIDs that could be visualized using ASOCT were within 1 mm of their intraoperative measured values. Therefore, ASOCT is a reliable tool for measuring the LMID of previously operated horizontal recti muscles, where the scarred tissue from older surgeries/lost data about previous surgeries makes it difficult for the operating surgeon to plan reoperations.</p>\",\"PeriodicalId\":51700,\"journal\":{\"name\":\"Strabismus\",\"volume\":\" \",\"pages\":\"1-9\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2025-06-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Strabismus\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/09273972.2025.2512788\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Strabismus","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/09273972.2025.2512788","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价前段光学相干断层扫描(ASOCT)在斜视再手术中测量水平直肌边缘肌插入距离(LMID)的准确性,并与术中卡尺测量结果进行比较。方法:选取30例(60块肌肉)行水平直肌斜视再手术治疗残余/连续斜视的成人患者。入组的受试者术前接受了先前手术的水平直肌LMID的ASOCT测量,并将其与再次手术时获得的术中卡尺值进行比较。结果:ASOCT成功成像90%的肌肉。ASOCT测量内侧直肌(MR)和外侧直肌(LR)的平均LMID分别为7.96±2.02 mm和8.74±2.81 mm,与术中卡尺测量值(MR为7.93±2.81 mm, LR为9.03±2.79 mm)相差1 mm以内。Bland-Altman图显示,两种测量值在MR和LR之间具有很强的一致性,两种测量方法之间具有良好的类间相关系数(MR: 0.96, LR: 0.98;p结论:在我们的研究中,100%使用ASOCT可以看到的lmid与术中测量值相差在1mm以内。因此,ASOCT是测量以前手术过的水平直肌LMID的可靠工具,因为以前手术留下的疤痕组织/以前手术的数据丢失使得手术医生很难计划再次手术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessment of the reliability of anterior segment optical coherence tomography measurements in cases of strabismus reoperations: a tertiary care center study.

Objectives: To evaluate the accuracy of Anterior Segment Optical Coherence Tomography (ASOCT) in measuring the limbal muscle insertion distance (LMID) of previously operated horizontal recti muscles in strabismus reoperations, compared to intraoperative caliper measurements. Methods: Thirty adult patients (60 muscles) undergoing strabismus reoperation of horizontal recti muscles for residual/consecutive strabismus were enrolled. Enrolled subjects underwent preoperative ASOCT measurements of the LMID of previously operated horizontal recti muscles, which were compared with intraoperative caliper values obtained during reoperation. Results: ASOCT successfully imaged 90% of the muscles. The mean LMID for medial rectus (MR) and lateral rectus (LR) measured by ASOCT was 7.96 ± 2.02 mm and 8.74 ± 2.81 mm, respectively, which were within 1 mm of intraoperative caliper measurements (7.93 ± 2.81 mm for MR, 9.03 ± 2.79 mm for LR). Bland-Altman plot showed a strong agreement for MR and a good agreement for LR between the two measured values, with excellent interclass correlation coefficients between the two methods of measurement (MR: 0.96, LR: 0.98; p < .001). Conclusion: In our study, 100% of LMIDs that could be visualized using ASOCT were within 1 mm of their intraoperative measured values. Therefore, ASOCT is a reliable tool for measuring the LMID of previously operated horizontal recti muscles, where the scarred tissue from older surgeries/lost data about previous surgeries makes it difficult for the operating surgeon to plan reoperations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Strabismus
Strabismus OPHTHALMOLOGY-
CiteScore
1.60
自引率
11.10%
发文量
30
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信