{"title":"在250-MHz和500-MHz使用量子驱动先验增强定量声学显微镜中的三维射频数据。","authors":"Sayantan Dutta;Jonathan Mamou","doi":"10.1109/TUFFC.2025.3576239","DOIUrl":null,"url":null,"abstract":"Quantitative acoustic microscopy (QAM) uses ultrahigh-frequency ultrasound (>200 MHz) to create 2-D maps of acoustic and mechanical properties of tissue at microscopic resolutions (<inline-formula> <tex-math>$\\lt 8 ~\\mu $ </tex-math></inline-formula>m). Despite significant advancements in QAM, the spatial resolution of current systems, operating at 250 and 500 MHz, may remain insufficient for certain biomedical applications. However, developing a QAM system with finer resolution by using higher-frequency transducers is costly and necessitates skilled operators, and these systems are more sensitive to the outside environment (e.g., vibrations and temperature). This study extends a resolution enhancement framework by proposing a generalized 3-D approach for processing QAM radio frequency (RF) data. The framework utilizes a quantum-based adaptive denoiser, DeQuIP, implemented as a regularization-prior (RED-prior) to enhance QAM maps. Key contributions include temporal hyperparameter optimization, accelerated algorithm integration, and application of quantum interaction theory. DeQuIP employs quantum wave functions, derived from the acquired data, as adaptive transformations that function as an RED-prior. This enables the framework to generate a temporally tailored regularization functional, allowing accurate modeling of complex physical phenomena in ultrasound propagation and providing a significant advantage over traditional regularizations in QAM imaging. The effectiveness of the proposed framework in enhancing resolution is demonstrated through both qualitative and quantitative analyses of experimental 2-D parameter maps obtained from 250- and 500-MHz QAM systems, alongside comparisons with a standard framework. Our framework demonstrates superior performance in recovering fine and subtle details, enhancing the spatial resolution of QAM maps by 38.2%–39.5%, surpassing the state-of-the-art framework, which achieved only 13.4%–26.1% improvement, and shows notable visual improvements in spatial details when compared to histology images.","PeriodicalId":13322,"journal":{"name":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","volume":"72 8","pages":"1119-1133"},"PeriodicalIF":3.7000,"publicationDate":"2025-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Enhancing 3-D Radio Frequency Data in Quantitative Acoustic Microscopy Using Quantum-Driven Prior at 250 MHz and 500 MHz\",\"authors\":\"Sayantan Dutta;Jonathan Mamou\",\"doi\":\"10.1109/TUFFC.2025.3576239\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Quantitative acoustic microscopy (QAM) uses ultrahigh-frequency ultrasound (>200 MHz) to create 2-D maps of acoustic and mechanical properties of tissue at microscopic resolutions (<inline-formula> <tex-math>$\\\\lt 8 ~\\\\mu $ </tex-math></inline-formula>m). Despite significant advancements in QAM, the spatial resolution of current systems, operating at 250 and 500 MHz, may remain insufficient for certain biomedical applications. However, developing a QAM system with finer resolution by using higher-frequency transducers is costly and necessitates skilled operators, and these systems are more sensitive to the outside environment (e.g., vibrations and temperature). This study extends a resolution enhancement framework by proposing a generalized 3-D approach for processing QAM radio frequency (RF) data. The framework utilizes a quantum-based adaptive denoiser, DeQuIP, implemented as a regularization-prior (RED-prior) to enhance QAM maps. Key contributions include temporal hyperparameter optimization, accelerated algorithm integration, and application of quantum interaction theory. DeQuIP employs quantum wave functions, derived from the acquired data, as adaptive transformations that function as an RED-prior. This enables the framework to generate a temporally tailored regularization functional, allowing accurate modeling of complex physical phenomena in ultrasound propagation and providing a significant advantage over traditional regularizations in QAM imaging. The effectiveness of the proposed framework in enhancing resolution is demonstrated through both qualitative and quantitative analyses of experimental 2-D parameter maps obtained from 250- and 500-MHz QAM systems, alongside comparisons with a standard framework. Our framework demonstrates superior performance in recovering fine and subtle details, enhancing the spatial resolution of QAM maps by 38.2%–39.5%, surpassing the state-of-the-art framework, which achieved only 13.4%–26.1% improvement, and shows notable visual improvements in spatial details when compared to histology images.\",\"PeriodicalId\":13322,\"journal\":{\"name\":\"IEEE transactions on ultrasonics, ferroelectrics, and frequency control\",\"volume\":\"72 8\",\"pages\":\"1119-1133\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2025-06-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE transactions on ultrasonics, ferroelectrics, and frequency control\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/11021678/\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11021678/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
Enhancing 3-D Radio Frequency Data in Quantitative Acoustic Microscopy Using Quantum-Driven Prior at 250 MHz and 500 MHz
Quantitative acoustic microscopy (QAM) uses ultrahigh-frequency ultrasound (>200 MHz) to create 2-D maps of acoustic and mechanical properties of tissue at microscopic resolutions ($\lt 8 ~\mu $ m). Despite significant advancements in QAM, the spatial resolution of current systems, operating at 250 and 500 MHz, may remain insufficient for certain biomedical applications. However, developing a QAM system with finer resolution by using higher-frequency transducers is costly and necessitates skilled operators, and these systems are more sensitive to the outside environment (e.g., vibrations and temperature). This study extends a resolution enhancement framework by proposing a generalized 3-D approach for processing QAM radio frequency (RF) data. The framework utilizes a quantum-based adaptive denoiser, DeQuIP, implemented as a regularization-prior (RED-prior) to enhance QAM maps. Key contributions include temporal hyperparameter optimization, accelerated algorithm integration, and application of quantum interaction theory. DeQuIP employs quantum wave functions, derived from the acquired data, as adaptive transformations that function as an RED-prior. This enables the framework to generate a temporally tailored regularization functional, allowing accurate modeling of complex physical phenomena in ultrasound propagation and providing a significant advantage over traditional regularizations in QAM imaging. The effectiveness of the proposed framework in enhancing resolution is demonstrated through both qualitative and quantitative analyses of experimental 2-D parameter maps obtained from 250- and 500-MHz QAM systems, alongside comparisons with a standard framework. Our framework demonstrates superior performance in recovering fine and subtle details, enhancing the spatial resolution of QAM maps by 38.2%–39.5%, surpassing the state-of-the-art framework, which achieved only 13.4%–26.1% improvement, and shows notable visual improvements in spatial details when compared to histology images.
期刊介绍:
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control includes the theory, technology, materials, and applications relating to: (1) the generation, transmission, and detection of ultrasonic waves and related phenomena; (2) medical ultrasound, including hyperthermia, bioeffects, tissue characterization and imaging; (3) ferroelectric, piezoelectric, and piezomagnetic materials, including crystals, polycrystalline solids, films, polymers, and composites; (4) frequency control, timing and time distribution, including crystal oscillators and other means of classical frequency control, and atomic, molecular and laser frequency control standards. Areas of interest range from fundamental studies to the design and/or applications of devices and systems.